Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Hughes Power System supplier in Romania

Reclosers, sectionalisers, vacuum circuit breakers and EOA operators

Headquarters: Nättraby, Sweden

Request a quote

Who is Hughes Power System and what does it make?

Hughes Power System is a Swedish manufacturer based in Nättraby that carries out research and development, production and sales of high- and medium-voltage switchgear for indoor and outdoor use. Its line is based on solid insulation, without gas, and the products are designed to operate for more than 30 years without major maintenance. The company's test laboratory is rated up to 900 kV switching impulse voltage and 420 kV at power frequency. It addresses distribution networks, transformer stations, railway lines and tramways.

The medium-voltage range includes ACR reclosers (6/15, 22/27 and 33/40 kV classes), VXR kiosk-type reclosers (6/12 and 22/24 kV), TVS Autoself sectionalisers (6/15, 22/27 and 33/40 kV), which follow the reclosing sequence of the substation, VX4 indoor vacuum circuit breakers (6/12 and 22/24 kV) and EOA motorised operators for disconnectors. The ACR120 recloser, for example, has a maximum voltage of 12 kV, a continuous current of 630 A, a fault-making current of 50 kA, a breaking current of 20 kA, an operating temperature from -45 °C to +70 °C, a weight of 75 kg and complies with IEC 62271-100; the ACR121 version reaches 15 kV and 1250 A. In high voltage, the OVX outdoor vacuum circuit breakers are offered for 72.5 kV (OVX723, 2500 A), 123/126 kV (OVX1100, 3150 A) and 145 kV (OVX1400, 4000 A).

The equipment is used on medium-voltage overhead lines, in traction substations and in transformer stations. For a quotation, the voltage, rated current, short-circuit current, mounting location and type of control matter.

What do we supply from the Hughes Power System range?

ProductDescription
ACR and VXR reclosersACR120/ACR121 for the 6/15 kV classes, 630/1250 A, with a synchronised integrated disconnector; ACR for 22/27 and 33/40 kV; VXR, a kiosk-type recloser, for 6/12 and 22/24 kV.
TVS Autoself sectionalisersTime-voltage sectionalisers for 6/15, 22/27 and 33/40 kV, which follow the reclosing sequence of the substation.
OVX and VX4 vacuum circuit breakersOVX outdoor: OVX723 at 72.5 kV, OVX1100 at 123/126 kV, OVX1400 at 145 kV. VX4 indoor for 6/12 and 22/24 kV, solid, gas-free, with epoxy insulators.
EOA motorised operatorsOperators with a self-locking motor for disconnectors and earthing blades: EOA400/401, EOA500/501, EOA600 for railways, EOA650 for tramways, EOA700 for rotary disconnectors and EOA501TVS with automatic sectionalising.

Why Hughes Power System?

  • Solid insulation, SF6-free — reclosers, sectionalisers and vacuum circuit breakers with epoxy insulators with a silicone surface
  • ACR recloser with integrated disconnector and visible opening points — switching under load is possible, even without electrical power
  • OVX outdoor vacuum circuit breakers from 72.5 to 145 kV — solid, gas-free, with currents of 2500–4000 A
  • EOA400–EOA700 operators — models for distribution networks, railways, tramways and rotary disconnectors
  • In-house test laboratory, up to 900 kV switching impulse — type tests carried out within the company

Which Hughes Power System codes and series are requested most often?

CodeDescription
ACR120 / OVX120Recloser 12 kV, 630 A, 20 kA
ACR121 / OVX121Recloser 15 kV, 1250 A, 20 kA
VXRKiosk-type recloser, 6/12 and 22/24 kV
TVS AutoselfTime-voltage sectionaliser
VX4Indoor vacuum circuit breaker, 6/12 and 22/24 kV
OVX723Outdoor vacuum circuit breaker, 72.5 kV, 2500 A
OVX1100Outdoor vacuum circuit breaker, 123/126 kV, 3150 A
OVX1400Outdoor vacuum circuit breaker, 145 kV, 4000 A
EOA400/401Universal operator for distribution and railways
EOA500Universal high-power operator
EOA501High-power operator, wider cabinet
EOA600Operator for railway disconnectors
EOA650Operator for tramway disconnectors
EOA700Operator for rotary disconnectors
EOA501TVSOperator with automatic sectionalising

Where is Hughes Power System equipment used?

  • Overhead distribution networks — 6–40 kV reclosers and sectionalisers
  • Traction substations — disconnectors, EOA operators and circuit breakers for railway and tramway lines
  • Transformer stations — OVX vacuum circuit breakers of 72.5–145 kV
  • Underground networks — VX4 indoor distribution switchgear
  • Smart grids — operators with communication to SCADA

How do we supply Hughes Power System in Romania?

We can quote Hughes Power System reclosers, sectionalisers, vacuum circuit breakers and EOA operators. They are supplied to order, usually in 1–4 weeks for operators and accessories; reclosers, high-voltage circuit breakers and configured equipment can have longer lead times, depending on the specification. For a correct quotation, send us the rated voltage, continuous current, breaking current, mounting location, control voltage (24, 48 or 110 V DC) and communication protocol; for replacements, add the code from the nameplate. The exact lead time is confirmed in the quotation.

Interchangeability with switchgear from other manufacturers, even if the footprints are similar, is established on the basis of the mounting drawing.

Frequently asked questions about Hughes Power System

What products does Hughes Power System make?

Hughes Power System, from Nättraby (Sweden), makes high- and medium-voltage switchgear with solid insulation and vacuum circuit breakers: ACR and VXR reclosers, TVS Autoself sectionalisers, VX4 and OVX circuit breakers and EOA motorised operators for disconnectors.

How do I choose between an ACR recloser and a VXR kiosk-type one?

ACR is the pole-mounted recloser for the 6/15, 22/27 and 33/40 kV classes, and VXR is the kiosk-type recloser for 6/12 and 22/24 kV. The choice depends on voltage, current and mounting. Send us the line data.

Can you supply Hughes equipment in Romania, and within what lead time?

Yes, to order; usually in 1–4 weeks for operators and accessories, while high-voltage circuit breakers may need longer, depending on the specification. The exact lead time appears in the quotation.

Can I motorise an existing disconnector with an EOA operator?

EOA operators exist in versions for disconnectors with vertical movement (tilting) and with a horizontal rod (rotary), and suitability depends on the existing disconnector. Send us the disconnector model, the type of movement and the supply voltage, so we can identify the suitable EOA model.

What details should I give for a quotation on an outdoor vacuum circuit breaker?

The rated voltage (72.5, 123/126 or 145 kV), continuous current, breaking current, control voltage, installation altitude and standard. If you are replacing a unit, add its nameplate.

How do I request a Hughes Power System quotation?

Send the Hughes Power System code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote