Who is HSP Hochspannungsgeräte and what does it make?
HSP Hochspannungsgeräte GmbH is a company from Troisdorf, in Germany, that has made high-voltage bushings under its own brand since 1893. A transformer or wall bushing is the part that carries high-voltage current through the transformer tank, through the wall of a hall or into the GIS bay, and it is a sensitive point of the device.
The range is based mainly on resin-impregnated paper (RIP), in which the condenser core is wound from crepe paper and thin aluminium foils, vacuum-dried and then impregnated. The RIP transformer bushings reach 1,200 kV and 6,000 A, those for high currents 52 kV and 40,000 A, and those for GIS 550 kV and 4,000 A. For wall bushings there are dry RIP variants, oil-free, mountable at different angles. The range also includes RIS bushings, RIG bushings for generators and oil bushings, conventional or with eco-friendly fluid.
The bushings are fitted to power transformers in 110–400 kV substations, to generators and step-up transformers in power plants and at the outlets of electrical halls. When a bushing is faulty, the data on the nameplate matter: the voltage, the rated current, the lengths below and above the flange and the mounting interface, because the new part must fit the same flange. A new bushing is identified correctly from these data.
What do we supply from the HSP Hochspannungsgeräte range?
| Product | Description |
|---|---|
| RIP transformer bushings | Transformer bushing for outdoor installation (fluid–air), with a graded condenser core, a porcelain or composite insulator and aluminium or copper terminals. It goes up to 1,200 kV and 6,000 A. |
| RIP bushings for high currents | Bushing for high currents on generator step-up transformers, up to 52 kV and 40,000 A, in horizontal or vertical mounting, with aluminium external elements. |
| RIP wall and GIS bushings | Dry, oil-free bushings for walls (air–air) and for GIS (GIS–air). The one for GIS is built from cast resin and applies up to 550 kV. |
| RIS / RIG / fluid bushings | RIS bushings for transformers, RIG for generators and for high currents, plus conventional bushings with fluid or eco-friendly fluid, for the devices that require them. |
Why HSP Hochspannungsgeräte?
- RIP transformer bushings up to 1,200 kV and 6,000 A — graded condenser core, for outdoor installation, with porcelain or composite insulator
- RIP bushings for GIS up to 550 kV and 4,000 A — dry cast resin construction, without oil and without gas, mountable at several angles
- Bushings for high currents up to 52 kV and 40,000 A — intended for generator step-up transformers (GSU), with horizontal or vertical mounting
- Dry RIP wall bushings — for the connection between outdoors and indoors, with composite insulators with silicone sheds
- Modular design — dimensions can be customised, which helps in replacing an existing bushing without modifying the transformer flange
Which HSP Hochspannungsgeräte codes and series are requested most often?
| Code | Description |
|---|---|
| RIP | Resin-impregnated paper bushing, with condenser core, for transformer, wall or GIS |
| RIS | RIS transformer bushing |
| RIG | RIG bushing for generators and high currents |
Where is HSP Hochspannungsgeräte equipment used?
- 110–400 kV substations — bushings for power transformers
- Power plants — high-current bushings for step-up transformers
- GIS substations — the GIS–air connection through resin bushings
- HVDC lines — transformer and wall bushings for direct current
- Heavy industry — in-plant high-voltage transformers
How do we supply HSP Hochspannungsgeräte in Romania?
For an HSP bushing, we need the nameplate of the device or of the old bushing: the maximum voltage, the rated current, the insulation class, the lengths below and above the flange, the diameter and holes of the flange, the type of insulator (porcelain or composite) and the mounting position. The part is supplied to order; for high-voltage or custom items the lead time may be longer, depending on the specification, and is confirmed in the quotation. For a replacement on an existing flange, the transformer's outline drawing is useful.
Direct replacement of a bushing of another make with an HSP one is established on the basis of the nameplate and the outline drawing; commissioning tests remain with the customer.
Frequently asked questions about HSP Hochspannungsgeräte
What products does HSP Hochspannungsgeräte make?
HSP makes high-voltage bushings from Troisdorf: RIP transformer bushings (up to 1,200 kV), high-current (52 kV / 40,000 A), wall and GIS bushings, plus RIS, RIG and fluid bushings. They are parts that carry current through the transformer tank or through a wall.
How do I choose an HSP transformer bushing?
By the voltage and rated current, the type of external insulator (porcelain or composite), the terminal (aluminium or copper) and the flange interface. Send the nameplate of the old bushing and the lengths below and above the flange, so we can check whether the modular design fits.
Can you supply HSP bushings in Romania, and how long does it take?
Yes, they are supplied to order. The lead time to order is usually 1–4 weeks for ordinary configurations, but at high voltages or custom dimensions it may be longer and is confirmed in the quotation.
Can I replace an old oil-paper (OIP) bushing with a RIP one?
RIP bushings are dry, and the modular design allows custom dimensions. Compatibility, however, depends on the flange, the lengths below and above it and the rated current, so we ask for the nameplate data and the outline drawing before stating that a model fits.
What should I send for a quotation on a generator bushing?
The rated voltage (up to 52 kV), the current (up to 40,000 A), the mounting position (horizontal or vertical), the type of external insulator, the working environment (outdoor or isolated-phase enclosure) and the dimensions of the transformer flange. With these data we identify the suitable RIP or RIG series.
How do I request a HSP Hochspannungsgeräte quotation?
Send the HSP Hochspannungsgeräte code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.