Chroma ATE supplier in Romania
precision test instrumentation: electrical safety testers, programmable power supplies, electronic loads and battery test systems
Who is Chroma ATE and what does it make?
Chroma ATE is a Taiwanese manufacturer of precision test instrumentation, with ranges covering programmable AC/DC power supplies, electronic loads, battery test systems and electrical safety testers — hipot testers, grounding resistance testers and electrical safety analysers. From the Chroma range we can quote the electrical test equipment commonly used in compliance laboratories and in industrial production.
The electrical safety range is organised by levels of complexity: from 3-in-1 analysers (AC voltage, DC voltage, insulation resistance) in the 19052/19053/19054 series, to high-voltage hipot analysers, up to 10 kV AC and 20 kV DC, in the 19056/19057 series, to dedicated grounding resistance testers, such as model 19572, capable of test currents up to 45 A. On the power supply side, the programmable AC source series 61500 and 61600 cover powers from 500 VA to 90 kVA, and the regenerative systems of the 61800 series reach tens of kVA for grid testing.
In electrical compliance laboratories and in industrial production, the Chroma range covers both the electrical safety tests required for product certification and the programmable power supplies needed for validating electronic equipment.
What do we supply from the Chroma ATE range?
| Product | Description |
|---|---|
| Electrical Safety Analysers Series 19052/19053/19054 | 3-in-1 electrical safety analysers, combining the AC voltage (ACV), DC voltage (DCV) and insulation resistance (IR) test in one device, with a scanner option for 4 or 8 channels. Used for compliance testing of electrical equipment before certification. |
| High-Voltage Hipot Analysers Series 19056/19057 | High-power dielectric withstand (hipot) test analysers, with AC voltages up to 10 kV and DC voltages up to 20 kV, used for checking insulation on equipment with high electrical safety requirements. |
| Grounding Resistance Tester Model 19572 | Dedicated tester for grounding continuity, with a test current of up to 45 A and resistance measurement in the range from 0.1 mΩ to 510 mΩ. Compatible for integration with the hipot testers of the 19070 series, for combined electrical safety testing. |
| Programmable AC Power Supplies Series 61500/61600 | Programmable AC power supplies for testing electronic equipment and appliances at various grid voltages and frequencies, with powers from 500 VA to 90 kVA and a frequency range from 15 Hz to 2 kHz. Used for simulating grid conditions from various export markets. |
Why Chroma ATE?
- A broad range of electrical safety testing — from 3-in-1 analysers to high-voltage hipot testers
- Programmable AC sources from 500 VA to tens of kVA — for laboratory and grid testing
- Dedicated grounding resistance testers — test currents up to 45 A
- Battery test systems — from laboratory testing to series production
- Instrumentation used in the certification of electrical and electronic products
Which Chroma ATE codes and series are requested most often?
| Code | Description |
|---|---|
| 19052/19053/19054 | 3-in-1 electrical safety analyser ACV/DCV/IR |
| 19056/19057 | hipot analyser, up to 10kV AC/20kV DC |
| 19055/19055-C | hipot analyser, ACV/DCV/insulation |
| 19032/19032-P | multifunction electrical safety analyser |
| 19020 | multichannel hipot tester, 10 channels |
| 19572 | grounding resistance tester, up to 45A |
| 61500 | programmable AC power supply, 500VA-90kVA |
| 61600 | programmable AC power supply, 500VA-90kVA |
| 6500 | programmable AC power supply, 1.2-9kVA |
| 61700 | three-phase AC power supply, 1.5-12kVA |
| 61800-100 | regenerative grid simulator |
| 61809/61812/61815 | regenerative grid simulator, 9-15kVA |
Where is Chroma ATE equipment used?
- Electrical certification laboratories — 3-in-1 safety tests and hipot
- Production of electrical and electronic equipment — line testing
- Battery testing — laboratory and production systems
- Electrical grid testing — programmable AC sources and regenerative simulators
How do we supply Chroma ATE in Romania?
We supply Chroma ATE electrical safety test equipment and programmable power supplies, to order, usually in 1–4 weeks. For a quotation we need the exact code of the device (for example an analyser from the 19052 series or a source from the 61500 series), the test voltages and currents needed and the compliance standard targeted. The availability of each device is confirmed separately.
Laboratory accreditations for the tests performed with these devices remain with the laboratory; product certification remains the responsibility of the customer's laboratory or certification body.
Frequently asked questions about Chroma ATE
What types of devices does Chroma ATE make?
Chroma ATE makes precision test instrumentation: programmable AC/DC power supplies, electronic loads, battery test systems and electrical safety testers, such as hipot testers and grounding resistance testers.
How do I choose a Chroma ATE electrical safety analyser?
For combined voltage-insulation testing on ordinary equipment, the 3-in-1 models of the 19052-19054 series are suitable; for high-voltage requirements, up to 10 kV AC or 20 kV DC, the hipot analysers of the 19056/19057 series are used. Send us the test standard targeted for confirmation.
Do you supply Chroma ATE equipment in Romania?
We supply Chroma ATE devices to order, usually in 1–4 weeks from confirmation.
What information do you need for a quotation on a Chroma ATE source?
Send the series code (for example 61500 or 61700), the power and output voltage needed, the frequency range and whether you need a three-phase function, so we can check availability and prepare the quotation.
How do I request a Chroma ATE quotation?
Send the Chroma ATE code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Chroma ATE Inc. (manufacturer documentation)