Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Cleaver-Brooks supplier in Romania

For Cleaver-Brooks we quote CBEX, CBLE, ClearFire-CE, SwitchFire, LVR and Nebraska boilers, ProFire burners and boiler room equipment; for a quotation we need the fluid, the output, the pressure, the fuel and the data on the plate.

Founded in 1929

Request a quote

Who is Cleaver-Brooks and what does it make?

Cleaver-Brooks is an American manufacturer of boilers, burners and control systems for producing hot water and steam, founded in 1929. The programme covers firetube boilers (with flame tubes), watertube boilers (with water tubes), condensing boilers, electric boilers with electrodes or with immersion elements, heat recovery boilers (HRSG), waste heat boilers and skid-mounted solutions. Around the boiler, boiler room equipment is added: deaerators, feedwater systems, condensate tanks, economisers, water treatment, blowdown, ProFire burners and control systems.

In the firetube boilers, the CBEX, CBJT, CBLE, ICB and Ohio Special series cover commercial and industrial steam or hot water applications. For condensing hot water there is ClearFire-CE, a compact boiler with full condensing and variable-flow pumping, and SwitchFire, a stainless steel firetube boiler for operation on natural gas with fuel oil as a backup. For low-output steam, CBT is a vertical tubeless boiler, and ClearFire-H is a compact horizontal boiler. The electric boilers include the CR, HSB, S, WB and MVR immersion models, the jet-type electrode boiler and LVR, a compact 90–540 kW hydronic boiler.

At high output, the Nebraska industrial watertube boilers of type A, D and O produce superheated steam of up to 1,050 °F (approximately 565 °C), and the Max-Fire, modular and Slant/VC HRSG lines recover the heat of the flue gases. This equipment matters in industrial heating plants, process steam factories and other facilities that use steam or hot water.

What do we supply from the Cleaver-Brooks range?

ProductDescription
CBEX, CBJT, CBLE and ICB firetube boilersIntegrated firetube boilers, with boiler, burner and control designed together. CBEX and CBJT cover varied applications, CBLE has a compact footprint and easy maintenance, and ICB is an integrated three-pass package for steam or hot water.
ClearFire and SwitchFire condensing boilersClearFire-CE is a compact hydronic boiler, with high mass and full condensing; ClearFire-LC and SwitchFire complete the series. SwitchFire is a stainless steel firetube boiler for operation on natural gas with No. 2 fuel oil as a backup.
LVR, MVR and electrode electric boilersLVR is a 90–540 kW hydronic electric boiler, with modular resistance elements. MVR is a medium-voltage immersion boiler, with hot water or steam, and the jet-type electrode boiler uses the water as a resistance to produce steam.
Watertube boilers and HRSGThe Nebraska industrial boilers of type A, D and O and the MED module produce superheated steam, and the CBCW, with a membrane-wall furnace, produces saturated steam. The Max-Fire, modular HRSG and Slant/VC lines recover the heat of the flue gases in cogeneration plants.

Why Cleaver-Brooks?

  • Four boiler types in the same programme: firetube, watertube, electric and heat recovery, so the boiler is chosen by fuel, pressure and type of steam or hot water
  • ClearFire-CE and SwitchFire: condensing boilers for hot water, one with variable-flow pumping, the other on natural gas with fuel oil as a backup
  • Electric boilers for different regimes: LVR of 90–540 kW with no local emissions, CR, HSB, S, WB and MVR immersion models, a jet-type electrode boiler
  • Nebraska watertube boilers for superheated steam: A, D and O configurations, plus the MED module, with steam of up to 1,050 °F; CBCW produces saturated steam
  • Boiler room from the same family: deaerators, economisers, water treatment, blowdown, ProFire burners and boiler room controls

Which Cleaver-Brooks codes and series are requested most often?

CodeDescription
CBEXIntegrated firetube boiler with EX technology
CBJTFiretube boiler for varied applications
CBLECompact firetube boiler, steam or hot water
ICBIntegrated three-pass firetube boiler
ClearFire-CECompact hydronic boiler with full condensing
SwitchFireStainless steel firetube boiler, natural gas with fuel oil backup
CBTVertical tubeless boiler for steam
ClearFire-HCompact horizontal boiler for steam
LVRHydronic electric boiler, 90–540 kW
MVRImmersion electric boiler, medium voltage
FLXPackaged five-pass watertube boiler
M5MCompact watertube boiler with membrane walls
CBCWIndustrial watertube boiler with water-cooled furnace
Nebraska A/D/OIndustrial watertube boilers, superheated steam
Max-FirePackaged HRSG boiler with integral furnace
Max-FlowWaste heat boiler with membrane walls

Where is Cleaver-Brooks equipment used?

  • Process industry: steam and hot water from firetube and watertube boilers
  • Cogeneration and power plants: HRSG heat recovery boilers and waste heat boilers
  • Commercial buildings: ClearFire and SwitchFire condensing boilers for hot water
  • Electricity as a heat source: LVR, MVR and electrode electric boilers
  • Oil and gas: forced-circulation steam generators and boilers for superheated steam

How do we supply Cleaver-Brooks in Romania?

We can quote Cleaver-Brooks boilers, ProFire burners and boiler room equipment: deaerators, economisers, feedwater systems and control components. For a quotation we need the fluid (steam or hot water), the flow rate or output, the pressure and temperature, the fuel available, the mounting space and, for an existing boiler, the model and serial number from the plate. We supply to order, usually in 1–4 weeks for parts; depending on the specification, the lead time can be longer for complete boilers. The exact lead time is confirmed in the quotation.

The compliance of a boiler with local approval or permitting requirements is established from the design data and the working pressure.

Frequently asked questions about Cleaver-Brooks

What kinds of boilers does Cleaver-Brooks make?

Cleaver-Brooks makes firetube, watertube, condensing, electric and heat recovery (HRSG) boilers, plus ProFire burners, control systems and boiler room equipment: deaerators, economisers, feedwater systems and condensate tanks.

How do I choose between a CBLE firetube boiler and a watertube one?

Firetube boilers, such as CBLE, CBEX or ICB, serve the usual commercial and industrial steam or hot water applications. Watertube boilers are chosen for high pressures and flow rates or for superheated steam. Send us the fluid, the pressure, the temperature and the output.

Can I get a Cleaver-Brooks boiler in Romania, and how fast?

Yes, supplied to order. The lead time is usually 1–4 weeks for parts and accessories, depending on the item. A complete boiler has a longer lead time, which we confirm in the quotation once the output, pressure and fuel have been fixed.

What should I send for parts for an existing boiler?

We need the boiler model, the serial number from the plate, the year of manufacture, the fuel used and the code or name of the part. With these data we request the parts list and check the part. The compatibility of a part is confirmed once the boiler has been identified.

What data are needed for an LVR or MVR electric boiler?

For LVR we need the output (90–540 kW), the available voltage and the hot water regime. For MVR we add the medium voltage of the network and whether steam or hot water is required. With these we request the configuration and state the availability in the quotation.

How do I request a Cleaver-Brooks quotation?

Send the Cleaver-Brooks code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Cleaver-Brooks (manufacturer documentation)