CoolIT Systems supplier in Romania

For CoolIT we quote CHx and AHx CDUs, direct liquid cooling coldplates, loops and rack manifolds; for a quotation we need the cooling power, the type of installation, the temperatures, the components to be cooled and the nameplate data.

Founded in 2001 · Headquarters: Calgary, Canada

Request a quote

Who is CoolIT Systems and what does it make?

CoolIT Systems is a Canadian manufacturer of direct liquid cooling (DLC) systems for servers, data centres and high-performance computing clusters, established in 2001 and based in Calgary. The range includes coolant distribution units (CDU), direct cooling plates (coldplates) for processors and other components, coldplate loops, rack manifolds, piping systems for the cooling circuit and liquid-cooled servers, plus design and installation services.

The CDUs regulate the flow, manage the heat exchange and transfer the heat either to the ambient air or to the building's water circuit. The CHx 80 and CHx 200 models are rack CDUs for high-performance computing and enterprise servers, the CHx 2000 is a row CDU for artificial intelligence clusters, and the CHx 3000 is a row or building-level CDU, with 3 MW of cooling at an approach temperature difference (ATD) of 3 °C. The AHx 180 and AHx 240 are liquid-to-air CDUs, which reject heat directly into the air and need no connection to building water, so they suit existing spaces and colocation ones. The coldplates are validated at more than 300 W/cm² heat flux and up to 15 kW per chip, and the integrated loops capture between 70% and 100% of the server's heat. The rack manifolds distribute the liquid evenly to each server and allow a server to be serviced without shutting down the circuit.

Such systems appear in data centres and in computing clusters where the power density per rack exceeds what air can remove.

What do we supply from the CoolIT Systems range?

ProductDescription
CHx and AHx CDUsCoolant distribution units: CHx 80 and CHx 200 in the rack, CHx 2000 on the row, the 3 MW CHx 3000 on the row or at building level, and the liquid-to-air AHx 180 and AHx 240, which need no building water. They have integrated redundancy and smart flow control.
Direct cooling plates (coldplates)Plates for processors, accelerators, memory, networking and power supplies, designed on the thermal profile of the component, with CFD (computational fluid dynamics) optimisation and internal 2D and 3D channels. They are validated above 300 W/cm² and up to 15 kW per chip.
Coldplate loops and rack manifoldsIntegrated loops that connect the coldplates inside the server and capture 70–100% of the heat, plus rack manifolds that distribute the liquid evenly, with low pressure drop and individual server servicing.
Technology cooling system (TCS) and servicesPrefabricated piping and fittings for the cooling circuit, with mechanical couplings or components welded on site, plus design, manufacturing, installation and maintenance services for the liquid cooling installation.

Why CoolIT Systems?

  • CDUs from rack to row and building level — CHx 80 and CHx 200 in the rack, CHx 2000 on the row, the 3 MW CHx 3000, so the unit is chosen by cooling power and location
  • AHx 180 and AHx 240 liquid-to-air CDUs — reject heat directly into the air, with no connection to building water, for existing spaces and leased data centres
  • Coldplates validated at more than 300 W/cm² — designed on the thermal profile of each component, with a version validated at 15 kW
  • Coldplate loops for 70–100% heat capture — configurations for fanless servers, built around the motherboard
  • Standard or custom rack manifolds — mounted like a power distribution unit, for classic or vertical-blade configurations

Which CoolIT Systems codes and series are requested most often?

CodeDescription
CHx 80Rack CDU for high-performance computing and servers
CHx 200In-rack CDU for high-performance computing
CHx 2000Row CDU for artificial intelligence clusters
CHx 3000Row or building-level CDU, 3 MW
AHx 180Liquid-to-air CDU, no building water
AHx 240High-capacity liquid-to-air CDU
ColdplateDirect cooling plate for a processor or accelerator
15 kW coldplateDirect cooling plate validated at 15 kW
Coldplate loopIntegrated coldplate loop for a server
Rack manifoldRack manifold for liquid distribution
TCS pipingPrefabricated piping and fittings for the cooling circuit

Where is CoolIT Systems equipment used?

  • Data centres — CDUs and direct cooling loops for high-density racks
  • High-performance computing — clusters with coldplates and fanless servers
  • Artificial intelligence — row-level and building-level CDUs, up to 3 MW
  • Leased data centres and existing spaces — liquid-to-air CDUs with no connection to building water
  • Server manufacturers — coldplates and loops designed around the motherboard

How do we supply CoolIT Systems in Romania?

We can quote CoolIT components: CHx and AHx CDUs, coldplates, loops, rack manifolds and spare parts for existing systems. For a quotation we need the cooling power per rack or per row, the type of installation (with building water or liquid-to-air), the working temperatures, the type of coolant, the processors or accelerators to be cooled and, for an existing system, the model and series from the nameplate. We supply to order, usually in 1–4 weeks for components; depending on the specification, the lead time can be longer for complete systems. The exact lead time is confirmed in the quotation.

The compatibility of a coldplate with a processor or a server is established from the exact model of the component and of the motherboard.

Frequently asked questions about CoolIT Systems

What does CoolIT Systems make?

CoolIT makes direct liquid cooling systems: CDUs (CHx and AHx), coldplates for processors and other components, coldplate loops, rack manifolds, prefabricated piping for the cooling circuit and liquid-cooled servers, with design and installation services.

How do I choose between a CHx and an AHx CDU?

The CHx units are liquid-to-liquid CDUs, which transfer heat into the water of the building's system; the AHx 180 and AHx 240 are liquid-to-air, reject heat directly into the air and need no connection to building water. Send us the cooling power and whether you have building water available.

Do you supply CoolIT products in Romania, and how fast?

Yes, supplied to order. Components usually arrive in 1–4 weeks, while large CDUs and complete systems can have a longer lead time, confirmed in the quotation once we have fixed the cooling power, the type of installation and the working temperatures.

Can I replace a coldplate or a manifold in an existing rack?

We start from identifying the system: the server or CDU model, the series, the type of liquid and the connections used. With these we check the reference. Compatibility is confirmed on the basis of the exact model of the cooled component and of the motherboard.

What data do I send for a CDU quotation?

We need the cooling power required per rack or per row, the type of CDU wanted (in-rack, row, liquid-to-air), the temperatures of the liquid and of the building water, the flow rate, the installation space and the redundancy requirements. On this basis we guide the choice between the CHx and AHx models.

How do I request a CoolIT Systems quotation?

Send the CoolIT Systems code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.