Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

DAB DAB JET

DAB JET self-priming surface electric pumps with cast iron body, for water supply, irrigation and extraction from wells: models JET 62, 82, 102, 112, 92 and 132, with absorbed power of 0.72–1.49 kW, in single-phase (M) and three-phase (T) versions.

JET is the DAB range of self-priming centrifugal electric pumps with cast iron body, for water supply to buildings and irrigation, extraction of water from wells or from tanks and cisterns, and for pressure boosting. The data sheet of the range covers models JET 62, 82, 102, 112, 92 and 132, with a single-phase motor of 220–240 V (M) or, on models 82, 102, 112 and 132, three-phase 230/400 V (T). The pump works with clean, non-aggressive water, without solid or abrasive particles, but accepts a low content of sandy impurities and air bubbles; in uses covered by EN 60335-2-41 the liquid can be at 0…+35 °C, and for other uses 0…+40 °C. The pump body is in cast iron, the impeller, diffuser, Venturi tube and sand strainer are in technopolymer, and the mechanical seal is carbon/ceramic; installation is fixed, in a horizontal position.

For a quotation, send us the full code from the pump's nameplate (for example JET 82 M or JET 132 T), the type of supply (single-phase or three-phase), the frequency and voltage if they differ from the standard ones, and the flow, the head and, for a new installation, the suction depth or height. If the pump has to be replaced, a photo of the nameplate helps us identify the exact version, including the motor type on three-phase versions.

Models and codes

CodeNote
JET 62 MSingle-phase 1 × 220–240 V; P1 max 0.72 kW, P2 rated 0.44 kW (0.6 HP); 42 m at zero flow, 21.1 m at 3 m³/h; capacitor 12.5 µF; gross weight 10.5 kg.
JET 82 MSingle-phase 1 × 220–240 V; P1 max 0.85 kW, P2 rated 0.6 kW (0.8 HP); 47 m at zero flow, 20.3 m at 3.6 m³/h; capacitor 12.5 µF; gross weight 10.7 kg.
JET 82 TThree-phase 3 × 230–400 V; P1 max 0.86 kW, P2 rated 0.6 kW (0.8 HP); current 2.8–1.6 A; same curve as the JET 82 M (47 m at zero flow); gross weight 10.7 kg.
JET 102 MSingle-phase 1 × 220–240 V; P1 max 1.13 kW, P2 rated 0.75 kW (1 HP); 53.8 m at zero flow, 25.8 m at 3.6 m³/h; capacitor 16 µF; gross weight 12.5 kg.
JET 112 TThree-phase 3 × 230–400 V, IE3 motor (P1 max 1.3 kW) or IE2 (1.35 kW); P2 rated 1 kW (1.36 HP); 61 m at zero flow, 20 m at 3.6 m³/h; gross weight 13.5 kg.
JET 92 MSingle-phase 1 × 220–240 V; P1 max 0.94 kW, P2 rated 0.75 kW (1 HP); 36.2 m at zero flow, 17 m at 4.8 m³/h; capacitor 14 µF; gross weight 11.7 kg.
JET 132 MSingle-phase 1 × 220–240 V; P1 max 1.49 kW, P2 rated 1 kW (1.36 HP); 48.3 m at zero flow, 27.2 m at 4.8 m³/h; capacitor 25 µF; gross weight 13.5 kg.

Key specifications

Flow (selection table)up to 3 (JET 62), 3.6 (JET 82, 102, 112) and 4.8 (JET 92, 132) m³/h
Head at zero flow36.2–61 (depending on model) m
Liquid temperature0…+35 for uses covered by EN 60335-2-41; 0…+40 for other uses; ambient max. +40 °C
Maximum working pressure8 bar
Supplysingle-phase 220–240 V / 50 Hz (M); three-phase 230/400 V / 50 Hz (T); other frequencies and voltages on request
Absorbed power P1 max0.72–1.49 kW
Protection and insulationmotor IP 44; terminal box IP 55; insulation class F
Materials in contact with the liquidcast iron body 200 UNI ISO 185; impeller, diffuser, Venturi tube and sand strainer in technopolymer; stainless steel wear ring; carbon/ceramic mechanical seal; NBR gaskets
Connections and weight1″ (columns DNA and DNM in the dimensions table); gross weight, with packaging, 10.5–13.5 kg

The data sheet "JET – Self-priming centrifugal pumps" (code 50250025, edition 05/2021) is the technical document of the range published on the JET page of the DAB Pumps website, where the instruction manual and the declarations of conformity are also listed; the range is current. The same page presents the extended JET range: JET with cast iron body, JET INOX with stainless steel body and JET COM with technopolymer body, while the larger models JET 151, JET 251, JET 200 and JET 300 have separate pages.

Frequently asked questions

What is the difference between the JET M and JET T versions?

In the data sheet tables, the M versions have a single-phase supply of 1 × 220–240 V, with a permanently fitted capacitor and built-in thermal-amperometric protection, while the T versions have a three-phase supply of 3 × 230–400 V. The data sheet recommends overload protection for the three-phase motor, in accordance with the legislation in force. On models 102, 112 and 132, the data sheet lists the T versions with IE3 and IE2 motors, with slightly different power and current values.

What liquids can the JET pump?

Clean, non-viscous, non-aggressive and chemically neutral water, without solid or abrasive particles; small amounts of sandy impurities and air bubbles are accepted, thanks to the self-priming capability. For uses covered by EN 60335-2-41 the liquid temperature is 0…+35 °C, and for other uses 0…+40 °C.

How is the pump installed?

The data sheet provides for fixed installation, in a horizontal position, with a maximum ambient temperature of +40 °C. The power cable is not included in the delivery.

Other DAB series

The curves, power, current, dimensions and weight differ from one model to another, and on the three-phase versions by motor type; before quotation we confirm the model, the supply and the motor type on the exact code from the nameplate, from the DAB data sheet.

Updated: 2026-11-23