Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Datexel supplier in Romania

For Datexel we quote DAT5021, DAT5022, DAT511 and DAT512 isolators and signal converters, Modbus TCP I/O modules from the DAT80xx series, Modbus RTU and PROFINET IO modules, gateways and power supplies; we need the full code and the signal type.

Founded in 1992 · Headquarters: Lonate Ceppino, Italy

Request a quote

Who is Datexel and what does it make?

Datexel, from Lonate Ceppino (Varese), makes electronic components for industrial automation and process control. The range covers signal transmitters and converters, galvanic isolators, I/O modules for Modbus RTU, Modbus TCP, CANopen and PROFINET IO, client-server units, gateways and serial interfaces, displays and power supplies.

On the signal side, the DAT5021 is a voltage and current converter with three-way galvanic isolation, and the DAT5022 is a separator with four-way isolation and two outputs. The DAT511 and DAT512 are self-powered 0–20 mA loop isolators, with one channel and two channels respectively. All are mounted on a DIN rail, in a vertical position, and the accepted signals include 0–10 V, 0(4)–20 mA, 2–10 V, 0–5 V and 1–5 V.

The I/O modules for Modbus TCP form the DAT80xx series: the DAT8014 reads four inputs for resistance thermometers and potentiometers, the DAT8016 four inputs for millivolts and thermocouples, and the DAT8130 combines eight digital inputs with four relays. For Modbus RTU there are the DAT20xx and DAT100xx series, and for PROFINET IO the DAT110xxPN series. Application sectors include energy, oil, food processing, chemicals, water treatment and paper. The range also includes software, drivers and configuration interfaces with cables; the CVPROG interface configures Datexel devices, except for the Smart ATEX series. For a quotation, send the full code.

What do we supply from the Datexel range?

ProductDescription
Isolators and signal convertersThe DAT5021 converts voltage and current signals with three-way isolation, and the DAT5022 separates them onto two outputs. The DAT511 and DAT512 are self-powered 0–20 mA loop isolators, with one or two channels.
Modbus TCP I/O modules, DAT80xx seriesThe DAT8014, DAT8015 and DAT8016 each have four isolated analogue inputs, the DAT8017 and DAT8018 have eight inputs isolated in pairs, the DAT8024 has four analogue outputs, and the DAT8130 and DAT8188 are digital modules.
Modbus RTU and PROFINET IO I/O modulesThe DAT20xx and DAT100xx series work on Modbus RTU/ASCII, with versions for resistance thermometers, millivolts, thermocouples and digital inputs. The DAT110xxPN series, of decentralised I/O, works on PROFINET IO, with the same signal types.
Gateways, displays and power suppliesThe range also includes client-server units, gateways and serial interfaces, displays and power supplies, for assembling a complete system from the same family. The CVPROG interface is used to configure the devices.

Why Datexel?

  • 3-way or 4-way galvanic isolation on the DAT5021 and DAT5022 — separates the measuring loop from the rest of the installation
  • Self-powered loop isolators DAT511 and DAT512 — need no auxiliary power supply
  • I/O modules on four protocols — Modbus RTU, Modbus TCP, CANopen and PROFINET IO
  • Inputs for resistance thermometers, thermocouples, voltage and current — the same module covers several sensors
  • DIN rail mounting — the devices go into the cabinet like any automation module

Which Datexel codes and series are requested most often?

CodeDescription
DAT5021Voltage and current converter with three-way galvanic isolation
DAT5022Separator-converter with four-way isolation and two outputs
DAT511Self-powered 0–20 mA loop isolator, one channel
DAT512Self-powered 0–20 mA loop isolator, two channels
DAT8014Modbus TCP module with four isolated inputs for resistance thermometers
DAT8016Modbus TCP module with four inputs for mV and thermocouples
DAT8017-IModbus TCP module with eight ±20 mA current inputs
DAT8024Modbus TCP module with four 0(4)–20 mA or 0–10 V analogue outputs
DAT8130Modbus TCP module with eight digital inputs and four relays
DAT8188Modbus TCP module with eight digital inputs and eight PNP outputs
DAT2014Modbus RTU/ASCII module for resistance thermometers
DAT11014PNDecentralised PROFINET IO module for resistance thermometers

Where is Datexel equipment used?

  • Energy — electronic components for automation
  • Oil and chemicals — converters and I/O modules for automation
  • Food and pharmaceutical — components for process automation
  • Water treatment — converters, isolators and power supplies
  • Paper — components for automation and process control

How do we supply Datexel in Romania?

We quote Datexel converters and isolators, I/O modules from the DAT80xx, DAT20xx, DAT100xx and DAT110xxPN series, as well as gateways and power supplies. For an exact quotation we need the full code from the device, the type and range of the input and output signal, the protocol and, for modules, the number of channels. For replacements, send a photo of the label. We supply to order, usually in 1–4 weeks; the lead time may be longer depending on the specification and is set in the quotation.

Input and output ranges are set on each device, which is why we ask for the exact signal values before confirming a version.

Frequently asked questions about Datexel

What are the DAT511, DAT512, DAT8014 and DAT8024 from Datexel?

The DAT511 and DAT512 are self-powered 0–20 mA loop isolators, with one channel and with two respectively. The DAT8014 is a Modbus TCP module with four isolated inputs for resistance thermometers, and the DAT8024 is a Modbus TCP module with four 0(4)–20 mA or 0–10 V analogue outputs.

How do I choose between the DAT5021 and the DAT5022?

The DAT5021 converts a voltage or current signal with three-way isolation, and the DAT5022 has four-way isolation and two separate outputs, so it feeds two receivers. Send the input signal range, for example 0–10 V or 4–20 mA, and the output range.

Do you supply Datexel products in Romania?

Datexel products are supplied to order, usually in 1–4 weeks. A device can ship in 24–72 h when the item is in stock, locally or at the supplier. For less commonly configured modules the time increases, and the quotation confirms the exact date.

Can I replace a Modbus RTU module with a Modbus TCP one?

Yes, but the communication interface differs: the DAT20xx and DAT100xx series work on Modbus RTU, and the DAT80xx on Modbus TCP, so the replacement is analysed together with the existing network. Send the current code and the protocol wanted, and we check the version.

What data do I need to send for a Datexel I/O module?

The full code from the label is enough. Otherwise state the protocol, the number and type of input and output channels, for example resistance thermometer, thermocouple, ±10 V or ±20 mA, the supply voltage and the DIN rail mounting. With these data we prepare the quotation.

How do I request a Datexel quotation?

Send the Datexel code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote