Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Dräger supplier in Romania

Medical and industrial safety technology

Founded in 1889 · Headquarters: Lübeck, Germany

Request a quote

Who is Dräger and what does it make?

For over 135 years, Dräger has been saving lives through gas detection technology and respiratory protection equipment. Dräger is a European manufacturer of portable multi-gas detectors, self-contained breathing apparatus for firefighters and miners, protective masks for the chemical industry and fixed atmosphere-monitoring systems for confined spaces. The manufacturer's electrochemical, infrared and catalytic sensor technology is used internationally - from oil refineries to mines, from laboratories to metro tunnels.

The Dräger range includes compressed-air breathing apparatus (SCBA) for firefighters and response teams.

What do we supply from the Dräger range?

ProductDescription
Dräger X-am 8000 Multi-Gas DetectorX-am 8000 is a Dräger portable multi-gas detector that measures up to 7 toxic or flammable gases and vapours, plus oxygen, with 5 sensor ports (CAT, IR, PID and EC technologies), an integrated pump for hoses of up to 45 m and IP 68 protection, per the manufacturer's documentation. Battery life exceeds 24 hours, and the audible alarm is 100 dB.
Dräger PSS 7000 Breathing ApparatusPSS 7000 is a Dräger compressed-air breathing apparatus for firefighters and industrial response teams.
Dräger Regard 7000 Fixed Gas Detection SystemRegard 7000 is a control system for fixed gas detection, intended for continuous monitoring in industrial installations.
Pac 8000 Single Gas Portable DetectorPac 8000 is a reusable Dräger portable single-gas detector, intended for personal monitoring; per the manufacturer's documentation it can detect 29 different gases, has a battery lasting 2 years of continuous operation, IP 68 protection, a weight of about 106 g and a 90 dB audible alarm, with Bluetooth data transmission.

Why Dräger?

  • Range of detectors - portable detectors and fixed systems for gas detection, per the manufacturer's documentation
  • X-am 8000 multi-gas detector - measures up to 7 toxic or flammable gases and vapours, plus oxygen, with 5 sensor ports, per the manufacturer's documentation
  • Approvals for Ex zones are confirmed from the datasheet of each model
  • Calibration and service - carried out by the manufacturer or by a third-party service centre; we supply the equipment, and service work is outside our offer
  • Fixed systems - Regard 7000 is a control system for fixed gas detection

Which Dräger codes and series are requested most often?

CodeDescription
X-am 3500Portable multi-gas detector for firefighting and rescue operations
X-am 8000Portable detector for up to seven gases plus oxygen
Pac 6000Portable single-gas detector from the Pac series for personal monitoring
Pac 6500Portable single-gas detector, Pac series version
Pac 8000Reusable portable single-gas detector, for 29 gases
Pac 8500Portable single-gas detector from the Pac series for industrial applications
X-pid 9500Portable PID detector for selective toxic substances
Polytron 8100Fixed gas transmitter for monitoring production sites
Regard 3900Simple control panel for fixed gas detection systems
Regard 7000Complete control system for gas detection, multi-vendor compatible

Where is Dräger equipment used?

  • Oil & gas (refineries, extraction)
  • Chemical and petrochemical industry
  • Pharmaceutical industry
  • Firefighters and emergency services
  • Mines and quarries
  • Tunnels and metro
  • Water treatment and sewerage
  • Food industry (CO₂)
  • Confined spaces and tanks
  • Power generation (power plants)

How do we supply Dräger in Romania?

We follow the manufacturer's technical documentation when describing gas detectors and breathing apparatus. We confirm the availability of the requested Dräger product in the quotation. We bring in Dräger products to order; as a general rule, for orders fulfilled from current supply, an order can ship in 24–72 h when the item is in stock, locally or at the supplier, and to order, usually 1–4 weeks for the rest of the range or special equipment. For a quotation, send us the exact product code (for example X-am 8000 or Pac 8000), the gases to be detected and the quantity needed, and we will come back with the quotation and the confirmed delivery time.

Calibration and manufacturer-warranty service for Dräger breathing apparatus or detectors are outside our offer.

Frequently asked questions about Dräger

What is the difference between the Drager Pac 6000 and the Pac 8000?

Both are portable single-gas detectors from the Pac series, designed for personal monitoring of exposure to a single type of gas. Pac 6000 is a disposable model, with a fixed service life of 2 years, for CO, H2S, SO2 or O2, while Pac 8000 is reusable and can detect 29 different gases. The right choice depends on the gas monitored, the working environment and the internal sensor maintenance requirements.

What is the Drager Regard 7000 system?

Regard 7000 is a control system for fixed gas detection, used to centralize the signals from several sensors and to reduce false alarms in industrial installations. It can work together with Drager detectors and, in certain configurations, with equipment from other manufacturers connected to the same network. It is suitable for facilities where several gas risk points are monitored simultaneously.

Do you supply Drager gas detectors in Romania to order?

Drager equipment is sourced individually, after the specifications in the manufacturer's technical documentation are confirmed; availability is checked on each request. Lead time on order is usually 1–4 weeks, depending on the model and on availability in the Drager network. For a quick answer it is useful to state the gas to be detected and the environment of use, industrial or emergency response.

What should I specify for a quotation on a Drager detector?

State the type of gas or gases to be detected, the environment of use, confined space, industrial or emergency response, and whether you need a portable detector or a fixed system with a transmitter. Information about the certifications required for the work zone and the number of monitoring points wanted also helps. With these details we identify the suitable Drager model from the X-am, Pac or Polytron range.

How do I request a Dräger quotation?

Send the Dräger code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Drägerwerk AG & Co. KGaA (manufacturer documentation)