Fire & Gas Detection Technologies (FGD) supplier in Romania
FlameSpec optical flame detectors, with HD video versions
Founded in 2017 · Headquarters: Anaheim, USA
Who is Fire & Gas Detection Technologies (FGD) and what does it make?
Fire & Gas Detection Technologies, Inc. (FGD) is an American manufacturer of optical flame detectors, based in Anaheim, California, founded in 2017. The factory there has a capacity of over 20,000 detectors a year. The range is named FlameSpec and covers triple infrared (IR3), UV-IR and hydrogen detectors, most with a version that adds an integrated HD video camera.
The particular feature of the range is the video camera in the body of the detector: the IR3-HD records colour images up to about 30 m, with recording that starts one minute before detection and lasts up to four minutes, which allows an alarm to be verified without exposing personnel in the hazardous area. The Blade detector combines the three IR wavelengths with near-infrared imaging and video algorithms, for high immunity to flare reflections. The IR3 detects a 0.1 m² heptane fire at up to 80 m, with a response under 1.5 seconds at 30 m.
FlameSpec appears at refineries, terminals, platforms and compressor stations, or as an alternative to existing flame detectors when video recording functions are required or the version for hydrogen, methane, ammonia and methanol. The outputs are universal (4–20 mA, relays, RS485 Modbus RTU), so integration into existing control systems is direct.
What do we supply from the Fire & Gas Detection Technologies (FGD) range?
| Product | Description |
|---|---|
| FlameSpec IR3 and IR3-HD | Triple IR detector for hydrocarbon fires, visible and non-visible. It detects a 0.1 m² heptane fire up to 80 m; the HD version adds colour video and automatic recording of events. |
| FlameSpec IR3-H2 and StretcH2 | Detectors for energy transition applications: hydrogen, methane, syngas, ammonia and methanol (IR3-H2), and hydrogen plus hydrocarbons (StretcH2) respectively. They have an ultra-fast 40 ms mode. They have 4–20 mA, relay and RS485 Modbus RTU outputs, so they integrate easily into existing control systems. |
| FlameSpec UV-IR and UV-IR-F | UV-IR detectors for a wide variety of fires, including hydrogen and methane-hydrogen mixtures. Sensitivity up to 30 m on a 0.1 m² heptane fire, with a 5 ms mode for explosions. |
| FlameSpec Blade | Detector that adds near-infrared imaging and video algorithms to the IR3-HD platform, aimed at immunity to flare reflections. It detects a 0.1 m² heptane fire up to 45 m. |
Why Fire & Gas Detection Technologies (FGD)?
- HD camera integrated in the detector (the -HD versions) — the alarm is verified on the image, with video recorded from before detection
- Triple IR with three sensors on the same field of view — immunity to false alarms, including from arc welding
- Models for hydrogen and the energy transition (IR3-H2, StretcH2) — they detect hydrogen, methane, ammonia and methanol flames
- Ultra-fast detection in 40 ms for fireballs and explosions — relevant in enclosed spaces
- Universal 4–20 mA, relay and Modbus RTU outputs — they fit into existing control systems
Which Fire & Gas Detection Technologies (FGD) codes and series are requested most often?
| Code | Description |
|---|---|
| IR3 | Triple IR detector for hydrocarbons |
| IR3-HD | IR3 with HD video camera |
| IR3-CO2L | IR3 version with a mode optimised for hangars |
| IR3-H2 | IR3 detector for hydrogen, ammonia, methane, syngas |
| StretcH2 | Detector for hydrogen and hydrocarbon flames |
| UV-IR | UV-IR detector for hydrocarbons and hydrogen |
| UV-IR-F | UV-IR version for hydrocarbons |
| Blade | Detector with NIR imaging and video algorithms |
| FlameView | Tool for validating the detector's field of view |
| Flame Simulators | Flame simulators for testing detectors |
Where is Fire & Gas Detection Technologies (FGD) equipment used?
- Flame detection — flare immunity in oil and gas installations
- Onshore oil and gas — refineries, terminals and storage
- Hangars and loading bays — version optimised for aircraft and trucks
- Energy transition — hydrogen, ammonia and methanol installations
- Industrial process lines — fire protection
How do we supply Fire & Gas Detection Technologies (FGD) in Romania?
From the FlameSpec range we can quote IR3, UV-IR, IR3-H2 and StretcH2 detectors, in versions with or without an HD camera, plus flame simulators and configuration software. They are supplied to order; the lead time is usually 1–4 weeks and is confirmed in the quotation. For a correct request we need the fuel to be detected, the maximum detection distance, the output type and whether video recording is needed. The field of view coverage study is the installation designer's task.
The coverage of a detector in a given zone results from the design study of the installation.
Frequently asked questions about Fire & Gas Detection Technologies (FGD)
What does Fire & Gas Detection Technologies make?
FGD makes in Anaheim, California, optical flame detectors from the FlameSpec family: triple IR, UV-IR and hydrogen versions, most also offered with an HD video camera, plus FlameView for field of view validation and flame simulators.
How do I choose between the IR3, UV-IR and IR3-H2?
The IR3 is used for hydrocarbons, the UV-IR for a wider range of fires, including hydrogen, and the IR3-H2 and StretcH2 are aimed at energy transition applications. The fuel, the distance and the environmental conditions decide; send them to us for a recommendation.
Do you supply FGD detectors in Romania, and within what time?
Yes. FlameSpec detectors, with or without an HD camera, are supplied to order, usually in 1–4 weeks. The lead time can differ by model and version; we confirm it in the quotation, once we know the fuel and the outputs needed.
Can I replace another flame detector with a FlameSpec?
Equivalence is established from data. We check the fuel, the distance, the voltage, the outputs (4–20 mA, relays, RS485) and the mounting flange, then we establish whether a FlameSpec can take over the role. Photos of the nameplate and the mounting bracket help the checking.
What data do you need for a quotation on a FlameSpec detector?
The fuel to be detected, the maximum distance, the supply voltage, the output type, whether you want HD video and the zone (hazardous area or not). If you are replacing an existing detector, add the code on its nameplate. A field of view coverage study, if there is one, completes the request.
How do I request a Fire & Gas Detection Technologies (FGD) quotation?
Send the Fire & Gas Detection Technologies (FGD) code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Fire & Gas Detection Technologies, Inc. (manufacturer documentation)