Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Generac Power Systems supplier in Romania

Generac Power Systems makes stationary generators and energy storage systems for data centres

Founded in 1959 · Headquarters: Waukesha, Wisconsin, USA

Request a quote

Who is Generac Power Systems and what does it make?

Generac Power Systems is an American manufacturer based in Waukesha, Wisconsin, founded in 1959, originally known for portable generators and today a supplier of standby power for industrial and commercial applications. From the industrial range we can quote high-power stationary generators, automatic transfer switches and energy storage systems for data centres, hospitals and production facilities. The range includes a 3.25 MW stationary diesel generator with an 87.5-litre engine.

What sets Generac's industrial segment apart from a plain list of standby generators is the breadth of its switching and storage range: the RTSN series of automatic transfer switches covers several variants (G3, J3, K3, R3), and the SBE energy storage systems come in three formats — container, cabinet and block — scalable from 200 kWh up to 5 MWh, with modules for thermal propagation safety and approvals for grid connection, according to the manufacturer's documentation.

On industrial platforms and in data centres, this Generac segment is suited where a complete standby package is sought — generator, automatic switching and, if needed, buffer storage — not just an isolated generator, especially in projects with UL certification requirements or integration with renewable sources.

What do we supply from the Generac Power Systems range?

ProductDescription
RTSN Series Automatic Transfer SwitchesAutomatic transfer switches, in the G3, J3, K3 and R3 variants, for switching between the utility grid and the standby generator at industrial facilities, hospitals or data centres.
RTSW and RTSI Series Transfer SwitchesTransfer switches in the RTSW and RTSI series, complementary to the RTSN range.
SBE Container, Cabinet and Block Energy Storage SystemsBattery-based systems, in three formats: SBE Container (200 kWh–1.7 MWh), SBE Cabinet (250 kWh–2 MWh) and SBE Block, for industrial scale (2.5–5 MWh). With approvals specified in the manufacturer's documentation for thermal propagation and grid connection, with integration for photovoltaic panels.
High-Power Stationary Diesel GeneratorDiesel generator with an 87.5-litre engine and 3.25 MW power, for facilities with high standby requirements — very large data centres or critical installations where a single set must cover a substantial load.

Why Generac Power Systems?

  • Automatic transfer switches in several variants G3/J3/K3/R3
  • SBE energy storage systems scalable from 200 kWh up to 5 MWh, in container, cabinet or block format
  • BESS modules with approvals according to the manufacturer's documentation for thermal propagation and grid integration
  • Over 65 years of activity in standby power equipment
  • Complementary mobile portfolio — generators, lighting towers, pumps and heaters for construction sites and temporary events
  • Industrial segment for data centres, hospitals and production facilities — standby generator, automatic switching and buffer storage in a single package

Which Generac Power Systems codes and series are requested most often?

CodeDescription
RTSN 100G3automatic transfer switch, G3 variant
RTSN 100J3automatic transfer switch, J3 variant
RTSN 100K3automatic transfer switch, K3 variant
RTSN 100R3automatic transfer switch, R3 variant
RTSN 200G3automatic transfer switch, G3 variant
RTSN 200J3automatic transfer switch, J3 variant
RTSN 400G3automatic transfer switch, G3 variant
RTSN 400K3automatic transfer switch, K3 variant
RTSN 600G3automatic transfer switch, G3 variant
RTSN 800G3automatic transfer switch, G3 variant
RTSW 100G3automatic transfer switch, RTSW series
RTSW 200G3automatic transfer switch, RTSW series
RTSI 100M3automatic transfer switch, RTSI series
RTSI 200M3automatic transfer switch, RTSI series
RXSW 200A3CULautomatic transfer switch, RXSW series
RXUW 150A3automatic transfer switch, RXUW series
RBU 150A3automatic transfer switch, RBU series
SBE Containercontainerised energy storage system, 200 kWh–1.7 MWh
SBE Cabinetmodular cabinet-type BESS system, 250 kWh–2 MWh
SBE Blockindustrial-scale BESS system, 2.5–5 MWh
Stationary Diesel Generator 3.25MWhigh-power stationary diesel generator, 87.5-litre engine

Where is Generac Power Systems equipment used?

  • Data centres — standby power and buffer storage for critical loads
  • Healthcare — automatic switching for hospitals and medical facilities
  • Industrial and manufacturing — generators and ATS for lines with critical shutdown
  • Oil and gas — mobile and stationary equipment for remote locations
  • Telecommunications — standby power for stations and network nodes
  • Water infrastructure — pumps and generators for treatment plants

How do we supply Generac Power Systems in Romania?

We can quote Generac Power Systems automatic transfer switches and energy storage systems from the technical documentation of the American manufacturer. We supply the equipment to order, usually in 1–4 weeks, depending on the configuration and the manufacturer's confirmation. For a quotation we need the power required, the type of application (standby, microgrid, storage), the voltage of the electrical switchboard and whether the installation requires UL certification or integration with renewable sources. This range is supplied to order — each industrial project is configured separately, starting from the real load to be covered.

For the Generac industrial range, orders from Romania are supplied to order.

Frequently asked questions about Generac Power Systems

What does Generac Power Systems make for industrial applications?

Generac Power Systems makes automatic transfer switches, battery-based energy storage systems and high-power stationary generators, alongside mobile equipment such as generators, lighting towers and pumps. The industrial segment addresses data centres, hospitals and production facilities with standby power needs.

How large can a Generac energy storage system be?

SBE systems are scalable from 200 kWh up to 5 MWh, in three formats: container (200 kWh–1.7 MWh), cabinet (250 kWh–2 MWh) and block, for industrial-scale installations. The modules have approvals for grid connection, indicated in the manufacturer's technical documentation.

Can Generac Power Systems be sourced in Romania or Europe?

Yes. We supply the equipment to order, usually in 1–4 weeks.

What information do I need to send for an automatic transfer switch quotation?

Please specify the power of the load to be switched, the voltage and number of phases of the electrical switchboard, the type of mounting (indoor or outdoor) and whether the installation requires specific UL or cUL certification. With this data we check the correct variant from the RTSN, RTSW or RTSI series.

How is a Generac BESS system integrated with existing photovoltaic panels?

SBE modules have approvals for grid-interactive operation, according to the manufacturer's documentation, which allows connection alongside photovoltaic inverters and generators in a single microgrid. The exact configuration depends on the installed power and the load profile of the facility.

How do I request a Generac Power Systems quotation?

Send the Generac Power Systems code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Generac Power Systems (manufacturer documentation)