Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Hekatron Brandschutz supplier in Romania

For Hekatron we quote Integral EvoxX control panels, ADW 535 linear detectors, ORS 142 and TDS 247 smoke switches and LRS 03 and LRS 04 Ex smoke switches; we need the type, variant and version of the existing control panel.

Headquarters: Sulzburg, Germany

Request a quote

Who is Hekatron Brandschutz and what does it make?

Hekatron Brandschutz is a German manufacturer of fire protection equipment for buildings and installations, headquartered in Sulzburg, in Baden-Württemberg, and active for over 50 years. The industrial range includes fire detection and alarm control panels, special detectors for harsh environments, hold-open systems for fire doors and smoke switches for ventilation systems. For a quotation, send us the type from the device, for example ORS 142, LRS 03 or Integral EvoxX C.

The Integral EvoxX control panels come in three variants: B, with one loop and up to 250 elements, C, with up to 4 loops and 1,000 elements, and M, with up to 16 loops and 4,000 elements per controller, for factories, office buildings or hospitals. They have VdS recognition and are configured with the Integral software. For areas where point detectors give false alarms or cannot reach, there are ASD aspirating smoke detectors, the ADW 535 linear heat detector, which withstands extreme temperatures, humidity, corrosive gases and dirty air, and the ILIA linear detector for very high rooms.

On fire doors and gates, the ORS 142 optical smoke switch triggers closing and is tested for use according to DIN EN 14637; for environments with dust or process smoke there is the TDS 247 thermal-differential switch. For air ducts, the LRS switches monitor smoke at air velocities of up to 20 m/s: the LRS 03 and LRS 230 V control fire dampers and smoke protection dampers, and the LRS 04 Ex works in Ex zones 1 and 2. These components appear in production halls, logistics warehouses and underground car parks.

What do we supply from the Hekatron Brandschutz range?

ProductDescription
Integral EvoxX fire detection control panelsIntegral EvoxX control panels B (one loop, up to 250 elements), C (up to 4 loops and 1,000 elements) and M (up to 16 loops and 4,000 elements per controller), with VdS recognition, the Integral IMAP operating panel and network connection through the Integral WAN Bridge.
ASD, ADW 535 and ILIA special detectorsASD aspirating smoke detectors for very early detection in difficult conditions, the ADW 535 linear heat detector for extreme temperatures, corrosive gases and dirty air, and the ILIA linear detector for rooms with high ceilings.
ORS 142 and TDS 247 smoke and thermal switchesThe ORS 142 optical smoke switch, in the W variant for wall mounting and the AT variant for replacement, and the TDS 247 thermal-differential switch for dusty environments, used in systems that hold fire doors open, with FSZ control panels.
LRS ventilation smoke switchesLRS switches for air ducts, at velocities of up to 20 m/s: the LRS 01 and LRS 02 control fans, the LRS 03 and LRS 230 V also control fire dampers and smoke protection dampers, with DIBt approval Z-78.6-177, and the LRS 04 Ex works in Ex zones 1 and 2.

Why Hekatron Brandschutz?

  • Scalable Integral EvoxX control panels — from one loop with 250 elements up to 16 loops with 4,000 elements per controller
  • Special detectors for harsh environments — the ADW 535 withstands extreme heat, humidity, corrosive gases and dirty air
  • ORS 142 smoke switch tested to DIN EN 14637 — reliable closing of fire doors and gates
  • LRS duct smoke switches up to 20 m/s — control of fans and fire dampers
  • Versions for Ex zones — LRS 04 Ex for zones 1 and 2 and door hold-open systems for Ex zones

Which Hekatron Brandschutz codes and series are requested most often?

CodeDescription
Integral EvoxX BFire alarm control panel, one loop, up to 250 elements
Integral EvoxX CFire alarm control panel, up to 4 loops and 1,000 elements
Integral EvoxX MFire alarm control panel, up to 16 loops and 4,000 elements
Integral IMAPOperating panel for Integral control panels
ADW 535Linear heat detector for harsh environments
ASDFamily of aspirating smoke detectors
ILIALinear detector for rooms with high ceilings
ORS 142Optical smoke switch for fire doors and gates
ORS 142 WOptical smoke switch for wall mounting
TDS 247Thermal-differential switch for environments with dust or smoke
AM 142Termination module for line monitoring
LRS 03Smoke switch for air ducts, fire damper control
LRS 04 ExSmoke switch for air ducts in Ex zones 1 and 2
LRS 230 VSmoke switch for air ducts, 230 V supply

Where is Hekatron Brandschutz equipment used?

  • Production halls — Integral EvoxX M control panels and ADW 535 linear detectors in dusty and hot areas
  • Logistics warehouses — ILIA linear detectors in high spaces and fire doors with ORS 142
  • Ventilation systems — LRS 03 smoke switches that control fire dampers
  • Explosive atmosphere zones — LRS 04 Ex and door hold-open systems for Ex zones
  • Underground car parks and technical rooms — Integral EvoxX B control panels with one loop

How do we supply Hekatron Brandschutz in Romania?

We quote Hekatron components for industrial fire protection installations: Integral EvoxX control panels, ASD, ADW 535 and ILIA special detectors, ORS 142 and TDS 247 smoke switches, control panels for fire doors and LRS smoke switches for ventilation. For a correct quotation, send us the type from the device, the variant (for example ORS 142 W or LRS 04 Ex), the supply voltage and, for extensions, the version of the existing control panel. We source them to order through EU supply channels, usually in 1–4 weeks, or in 24–72 h when the item is available locally or at the supplier.

We supply Hekatron components as replacement or extension parts; the design, commissioning and periodic checks of the fire alarm system remain with the certified specialist company that maintains it.

Frequently asked questions about Hekatron Brandschutz

What does Hekatron Brandschutz make for industry?

Hekatron, from Sulzburg, makes Integral EvoxX fire detection control panels, special smoke and heat detectors, systems that hold fire doors open until smoke appears, LRS family smoke switches for ventilation and voice alarm systems.

How do I choose the Integral EvoxX control panel variant?

The variant depends on the number of loops and elements: EvoxX B has one loop and up to 250 elements, EvoxX C up to 4 loops and 1,000 elements, and EvoxX M up to 16 loops and 4,000 elements per controller. Send us the number of detectors and modules in the project.

How soon do you supply Hekatron smoke switches in Romania?

An ORS 142 or LRS switch can ship in 24–72 h when the item is available locally or at the supplier. Ordered through import from the EU, a Hekatron switch usually arrives in 1–4 weeks. For control panels and system extensions, depending on brand and specification, the lead time can be longer.

Can we replace an old ORS 142 on an existing door system?

For replacement there is the ORS 142 AT variant. Send us a photo of the label, the type of control panel and the existing power supply: older supplies, such as the NAG 03 or NG 519, do not provide line monitoring according to DIN EN 14637, and this changes what we quote.

What data do I send for an LRS smoke switch on a ventilation duct?

The variant wanted (LRS 01, 02, 03, 230 V or 04 Ex), the air velocity in the duct, which must not exceed 20 m/s, the supply voltage, what the switch controls (the fan or the fire dampers) and, for the LRS 04 Ex, the Ex zone.

How do I request a Hekatron Brandschutz quotation?

Send the Hekatron Brandschutz code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 12 November 2026 · Sources: Hekatron Brandschutz (manufacturer documentation)