Eilersen supplier in Romania
Capacitive digital load cells, interface modules, OIML indicators
Founded in 1969 · Headquarters: Kokkedal, Denmark
Who is Eilersen and what does it make?
Eilersen Electric Digital Systems is a Danish company based in the Kokkedal industrial park, active since 1969, that makes digital load cells with a ceramic capacitive sensor, weighing interface modules, OIML digital indicators and scales. The capacitive principle, with no moving parts, lets the stainless steel cells withstand overloads of up to ten times the rated load. The company holds more than 10 patents, has customers in more than 90 countries and offers versions with metrology approvals and ATEX versions, according to the manufacturer's documentation, for zones 1, 2, 21 and 22.
The load cells are divided by shape and capacity range. The BL and SBL series are hygienic bar-type cells, from 1 to 1000 kg; BM 50, BM 70 and BM 80 cover 1000 to 7000 kg in stainless steel, IP68. The compression series CL, CM 125 and CM 150 range from 50 kg to 50 t, DLC and DMC have lift-off protection, and CH 100 and CH 500 reach 100–500 t. For single-point weighing there are SPSX, SPSXL and XBL, and for web tension TL 101A, TL 101B and TM. Every model has an "-Ex" version for explosive-atmosphere zones, and the accuracy class depends on the series.
The 4XXXA family of interface modules connects up to four cells to PROFINET, EtherCAT, Profibus DP, EtherNet/IP, Modbus TCP/IP, DeviceNet or RS485, with versions for explosion-hazard zones, according to the manufacturer's documentation. The 5024G and 5026G indicators work stand-alone, without a programmable controller, with alibi memory, batching and digital outputs with a response of up to 10 ms. This brand appears in silos, reactors and hoppers, where load cells replace mechanical weighing mechanisms or where a digital signal straight into the network is required.
What do we supply from the Eilersen range?
| Product | Description |
|---|---|
| BL / SBL / BM / CL / CM / DLC / DMC / CH load cells | Digital bar-type and compression cells, from 1 kg to 500 t, in hygienic designs with hygiene approvals stated in the manufacturer's documentation, in stainless steel IP68, with lift-off protection or for very heavy loads; all have Ex versions. |
| SPSX / SPSXL / XBL | Single-point cells for platforms and scales, in stainless steel IP68, from 3 to 300 kg, with declared accuracy down to 0.010% and overload of up to 1000%. |
| 4XXXA interface modules | Modules that connect up to four load cells to a fieldbus network, with integrated diagnostics; the versions for explosion-hazard zones include PROFINET (4X70A), EtherCAT (4X60A), Profibus DP (4X35A), EtherNet/IP (4X50A) and DeviceNet (4X37A). |
| 5024G and 5026G indicators | Digital indicators with an LCD display, alibi memory, batching and in-flight correction. The 5026G combines the indicator, the interface module and the power supply in a single hygienic housing. |
Why Eilersen?
- Digital load cells with a capacitive sensor — no moving parts and a high overload tolerance, declared for each series
- A version for explosion-hazard zones for every main series (BL-Ex, CL-Ex, CH-Ex etc.) — for zones 1, 2, 21 and 22 in silos and chemical plants
- A very wide capacity range, from 1 kg to 500 t — from laboratory batchers to large-volume silos and reactors
- 4XXXA modules with up to 4 cells and PROFINET, EtherCAT, Profibus DP, EtherNet/IP, Modbus TCP/IP, DeviceNet or RS485 interfaces
- Stand-alone 5024G / 5026G indicators, with alibi memory and batching — work without a PLC, for metrologically verified applications
Which Eilersen codes and series are requested most often?
| Code | Description |
|---|---|
| BL / BL-Ex | Hygienic digital bar-type cell, 10–1000 kg |
| SBL / SBL-Ex | Compact bar-type cell, 1–50 kg |
| BM 70 / BM-Ex 70 | Bar-type cell, 1000–3000 kg, stainless steel IP68 |
| CL / CL-Ex | Hygienic compression cell, 50–5000 kg |
| CM 125 / CM-Ex 125 | Compression cell, 6000–20000 kg |
| DLC / DLC-Ex | Compression cell with lift-off protection, 50–5000 kg |
| CH 100 / CH-Ex 100 | Compression cell for very heavy loads, 100 t |
| SPSX / SPSX-Ex | Single-point cell, 5–200 kg |
| TL 101A | Web tension cell, 500 N – 5 kN |
| 4X70A (4170A–4470A) | PROFINET interface module in a version for explosion-hazard zones, up to 4 cells |
| 4X60A (4160A–4460A) | EtherCAT interface module in a version for explosion-hazard zones, up to 4 cells |
| 4X35A (4135A–4435A) | Profibus DP interface module in a version for explosion-hazard zones, up to 4 cells |
| 4X50A (4150A–4450A) | EtherNet/IP or Modbus TCP/IP interface module in a version for explosion-hazard zones |
| 4X79A | Module with 4–20 mA or 0–10 V analogue output |
| 5024G | OIML digital weighing indicator |
| 5026G | Indicator with integrated interface module and power supply |
Where is Eilersen equipment used?
- Food and beverages — hygienic cells with hygiene approvals according to the manufacturer's documentation, for tanks and hoppers
- Chemicals and petrochemicals — versions for explosion-hazard zones
- Silos and bulk materials — compression cells and modules with a fieldbus network
- Strip and film production — TL 101A / TL 101B tension cells
- Reactors and batch processes — batching and verified weighing
How do we supply Eilersen in Romania?
We can order Eilersen digital load cells, interface modules and indicators, starting from the application data or from the existing series. We supply to order, usually in 1–4 weeks; configured systems or those with ATEX and OIML requirements can have a longer lead time, confirmed in the quotation. For a correct quotation you need to state the maximum capacity of each cell, the shape (bar, compression, single point), the accuracy class wanted, whether an Ex version is needed, the fieldbus protocol and the number of cells per module. A photo of the label on the existing cell or module, together with the classified zone, helps with identification.
OIML classes are confirmed model by model, from the documentation.
Frequently asked questions about Eilersen
What does Eilersen make?
The Danish company from Kokkedal, active since 1969, makes digital load cells with a ceramic capacitive sensor, interface modules for fieldbus networks, OIML weighing indicators and scales, with versions for explosion-hazard zones, according to the manufacturer's documentation.
How do I choose the capacity of an Eilersen cell?
Start from the maximum mass of the contents and the vessel, divided by the number of cells, with a margin for uneven loads. The series cover 1 kg to 500 t, and the accuracy class depends on the series. Send us the mass, the shape and the Ex zone.
Do you supply Eilersen products in Romania, and how fast?
Eilersen is supplied to order, usually in 1–4 weeks. Complete systems, versions for explosion-hazard zones and those with metrological verification sometimes have a longer lead time, confirmed in the quotation.
Can I replace an analogue cell with an Eilersen digital one?
Only after checking the mechanical form, the capacity and how it integrates into the network. The cells are digital, so they need a compatible module or indicator. Equivalence is confirmed on the basis of the data: send the series of the old cell and the system diagram.
What do I send for a quotation on interface modules?
The network protocol of the controller (PROFINET, EtherCAT, Profibus DP, EtherNet/IP, Modbus TCP/IP, DeviceNet or RS485), the number of cells, whether the module must be ATEX and the type of power supply. For modules already installed, add the type from the label.
How do I request a Eilersen quotation?
Send the Eilersen code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Eilersen Electric Digital Systems A/S (manufacturer documentation)