ELREHA supplier in Romania
For ELREHA we quote TAR, TKP, EVP and MSR controllers, the VPR 5340 central controller, EGS leak detectors, TAA displays and the Gateway for remote monitoring; we need the exact code, the voltage and the sensor type.
Founded in 1976 · Headquarters: Hockenheim, Germany
Who is ELREHA and what does it make?
ELREHA, from Hockenheim in Germany, has made electronic control systems since 1976, especially for refrigeration and air conditioning. The range covers controllers for temperature, pressure and humidity, controllers for cold rooms, controllers for parallel-compressor stations, CO2 installations, displays, alarm modules, refrigerant leak detectors and remote monitoring solutions.
The TAR series includes numerous controllers. TAR 1170 and TAR 1180 control temperature with defrost, TAR 1260-2 is a universal three-point controller for temperature, humidity and pressure, with an RS485 interface, and TAR 1810-2 controls cold rooms with real-time defrost. The TKP, EVP and KKS series control cold rooms (EVP 1140 with electronic valves, KKS 4100 for a single evaporator), and MSR 1100-2 controls compressor stages and condenser fans. VPR 5340 is the central controller for installations with several compressors, with expansion modules BMA, BMO and BMR.
For safety and records there are the EGS leak detectors, including for CO2, the SM 501 and TW 1300 alarms and the NA 405 device for cold rooms at very low temperatures. ELREHA Gateway sends the data to a web solution, and MiniMEP records temperature and humidity. For a quotation, the exact code, the supply voltage, the sensor type (Pt1000, PTC or 4–20 mA) and the interface matter.
What do we supply from the ELREHA range?
| Product | Description |
|---|---|
| TAR and EE controllers | TAR 1170, 1180, 1370-2 and 1810-2 control cold rooms with defrost, TAR 1260-2 is a universal three-point controller, and the EE series controls in two points or monitors liquid level and ice build-up. |
| TKP, EVP, KKS and MSR controllers | TKP and EVP control cold rooms, EVP 1140 works with electronic valves, KKS 4100 serves rooms with one evaporator, and MSR 1100-2 controls compressor stages, condenser fans and brine chillers. |
| VPR 5340 central controller | Controller for installations with several compressors, extended through modules BMA 3201 (analogue), BMO 3201 and 3202 (digital inputs) and BMR 3201 (relays). The SML 405 display completes the system. |
| Leak detectors, displays and monitoring | EGS 101 and variants, the EGS CO2 Set, TAA displays, SM 501 and TW 1300 alarms, the NA 405 call device and ELREHA Gateway, for sending data to a web solution. |
Why ELREHA?
- TAR controllers with integrated defrost — they control the cold room without a separate control module
- TAR 1260-2 covers temperature, humidity and pressure in one unit, with RS485 — fewer controller types need to be kept as spares
- VPR 5340 central controller with expansion modules — it manages installations with several compressors in a network
- EGS leak detectors, including for CO2 — safety in refrigeration installations with natural refrigerant
- Gateway for data transmission — installations are monitored remotely, with recording
Which ELREHA codes and series are requested most often?
| Code | Description |
|---|---|
| TAR 1170 | Temperature controller with defrost, one circuit |
| TAR 1180 | Temperature controller with defrost and a second relay output |
| TAR 1260-2 | Universal three-point controller, with RS485 |
| TAR 1810-2 | Controller for cold rooms, with real-time defrost |
| TKP 3130 | Controller for cold rooms |
| EVP 1140 | Controller for electronic valves |
| MSR 1100-2 | Stage controller for compressors and fans |
| VPR 5340 | Central controller for installations with several compressors |
| BMA 3201 | Analogue input and output module for VPR 5340 |
| EGS 101 | Refrigerant leak detector |
| SM 501 | Universal alarm unit |
| TAA 1515 | Remote display |
Where is ELREHA equipment used?
- Cold stores and refrigeration rooms — control and defrost
- CO2 refrigeration installations — controllers for booster and cascade stations
- Parallel-compressor stations — central control of the stages
- Air conditioning — control of temperature, humidity and pressure
- Monitoring and alarming of installations — leak detectors and remote transmission
How do we supply ELREHA in Romania?
From the ELREHA range we can quote controllers for refrigeration installations, expansion modules, displays and leak detectors. For a correct quotation, send the full code from the nameplate (for example TAR 1260-2), the supply voltage, the type and number of sensors, the outputs required and whether RS485 is needed. An ELREHA controller is supplied to order, usually in 1–4 weeks; the lead time is 24–72 h when the item is in stock, locally or at the supplier. The quotation sets the lead time.
Versions with a suffix or specific programming of the controllers are matched in the quotation, using the code and the parameters of the existing installation.
Frequently asked questions about ELREHA
What are TAR 1170, TKP 3130, VPR 5340 and EGS 101 at ELREHA?
TAR 1170 is the temperature controller with defrost, with one circuit, TKP 3130 is the controller for cold rooms, VPR 5340 is the central controller for installations with several compressors, and EGS 101 is the refrigerant leak detector.
How do I choose between a TAR 1170 and a TAR 1180 controller?
Both control temperature with defrost, but TAR 1180 also has a second relay output. The choice depends on the number of loads to be controlled, the sensor used and the supply voltage. Send us the installation diagram and we identify the suitable version.
Do you supply ELREHA in Romania, and how quickly?
An ELREHA unit is supplied to order, usually in 1–4 weeks; for special versions the time may be longer. We can ship it in 24–72 h when the item is in stock, locally or at the supplier. The quotation sets the lead time.
Can I replace an older ELREHA controller with a current one?
Yes, after we check the code on the nameplate, the voltage, the type of sensors and the outputs used. Some series are available in versions with a suffix or with Modbus. Send a photo of the nameplate and the wiring diagram, and we confirm the match before the quotation.
What data do I send for a TAR 1180 controller or an EVP 1140 controller?
The full code on the unit, the supply voltage, the type and number of sensors, the outputs required (relays, analogue), the interface (RS485 or Modbus) and the type of installation — cold room, compressor station or CO2 installation.
How do I request a ELREHA quotation?
Send the ELREHA code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: ELREHA Elektronische Regelungen GmbH (manufacturer documentation)