FACO supplier in Romania
For FACO we offer HVAC/R coils, industrial air/gas–water or oil heat exchangers, economizers, dry coolers and condensers, by fluid, temperatures, pressure, dimensions and the nameplate of the unit to be replaced.
Founded in 1963 · Headquarters: Varallo Pombia, Italy
Who is FACO and what does it make?
FACO is an Italian company founded in 1963, with its headquarters and factory in Varallo Pombia, in the province of Novara, specialised in finned tube heat exchangers: coils for air conditioning and refrigeration, heat exchangers for industrial processes, dry coolers and air-cooled condensers. Each finned block is designed to order, depending on the fluid, temperature, pressure and the material required.
FACO usually appears in two situations: as a replacement heat exchanger or coil on an imported machine, or as a project solution for cooling or heat recovery with special conditions. The range includes water, glycol or oil coils, refrigerant evaporators and condensers, steam coils, flue gas economizers, heat exchangers with safety double tubes, anti-seismic versions and versions with a removable header, which allow the inside of the tubes to be cleaned.
In the dry cooler area, the company builds V-type units with a reinforced structure and low noise, versions with special coatings for aggressive environments or offshore installation, compact indoor modules and the SmartBox module, a three-sided radiator mounted at the end of a generator set container. The thermal design uses in-house software, based on parameters measured in a test laboratory built to ASHRAE standards, and the structural calculation can follow ASME VIII div. 1 or EN 13445. For installations with special requirements, the version can be anti-seismic or shock-resistant, and the company's quality system is certified according to the manufacturer's documentation.
What do we supply from the FACO range?
| Product | Description |
|---|---|
| HVAC/R coils | Water, glycol or oil coils for heating and cooling, direct expansion evaporators, refrigerant condensers and steam coils for air handling units, with versions with a removable header, bare tubes, split core or air-tight casing. |
| Industrial heat exchangers | Air/gas–water and air/gas–oil heaters and coolers, air preheaters, air dryers, superheated water or steam generators and economizers for heat recovery from the flue gases of boilers, engines and turbines. |
| Dry coolers and condensers | Horizontal or vertical dry coolers, low-noise V-type units, offshore versions and compact indoor modules; accessories such as axial fans, defrosting systems, heating cables, access ladders and railings. |
| SmartBox | Compact cooling module with a three-sided radiator and fans mounted on top, which fits at the end of a generator set container; the multi-section version cools high temperature, low temperature and fuel circuits. |
Why FACO?
- Finned blocks made to order — circuiting, fin pitch, headers and materials chosen by fluid and working conditions, not from a fixed table of models
- Versions for cleaning — removable plugs or headers with a cover, useful when the fluid carries sludge, scale or microorganisms
- Safety double tubes — each tube has two coaxial tubes, and any leak ends up in a detection chamber, a solution used for cooling electric machines
- ThermoGuard frost protection — the pressure of water trapped in the bends is released through a secondary circuit to a safety valve
- Design documentation — calculation to ASME VIII div. 1 or EN 13445, compliance with the applicable directives, as stated in the manufacturer's documentation, and ATEX version, for dry coolers
Which FACO codes and series are requested most often?
| Code | Description |
|---|---|
| HVAC/R Coils | Finned coils for air conditioning and refrigeration |
| Industrial Heat Exchangers | Air/gas–water or oil heat exchangers, economizers |
| Drycoolers & Condensers | Dry coolers and air-cooled condensers |
| SmartBox | Cooling module for generator set containers |
| ThermoGuard | Frost protection system for coils |
| Removable plugs | Version with plugs for tube cleaning |
| Box headers | Headers with removable cover |
| Safety double-tube | Double-tube heat exchangers for leak detection |
| Heat pipe | Heat pipe heat exchangers for heat recovery |
| Bare tube economizer | Economizer with bare tubes for high temperatures |
| P40 | 5/8 inch tube geometry developed by the company |
| ATEX dry cooler | Horizontal or vertical dry cooler in a version for explosion-risk areas |
Where is FACO equipment used?
- HVAC and industrial refrigeration — cooling and heating coils for air handling units
- Energy and power generation — dry coolers for generator sets and auxiliary circuits
- Oil, gas and gas compressors — air/gas–water heat exchangers for process stations
- Waste heat recovery — economizers on flue gases of boilers and engines
- Chemicals, paper and food industry — heaters and air dryers with special materials
How do we supply FACO in Romania?
We can quote finned coils and heat exchangers, dry coolers and condensers from the FACO range, based on the data on the nameplate of the existing unit or on a process specification. The equipment is made to order, so we supply it to order; depending on the specification, the lead time may be longer. For a correct quotation we need the fluid and flow rate, the inlet and outlet temperatures, the working pressure, the block dimensions, the tube and fin material and, if available, the sketch of the coil to be replaced.
Each block is built to order from a drawing, so we confirm a dimensional equivalence once we have the sketch of the existing coil and the process parameters.
Frequently asked questions about FACO
What does FACO make?
FACO makes finned tube heat exchangers: coils for air conditioning and refrigeration, heat exchangers for industrial processes, dry coolers and air-cooled condensers. The headquarters is in Varallo Pombia, Italy, and the products are built to order, by fluid, temperatures, pressure and the materials required by the application.
What data do I need to size a finned coil?
Sizing starts from the fluid in the tubes, flow rate, inlet and outlet temperatures, air or gas flow rate and temperature, the permitted pressure drop and the available dimensions. If you are replacing an existing coil, its sketch and the unit nameplate shorten the check considerably.
Can you bring FACO heat exchangers to Romania and when do they arrive?
Yes. We supply to order; usually 1–4 weeks, but for configured versions, with special materials or design codes (ASME, PED), the lead time may be longer. We set the exact lead time in the quotation, after the factory's confirmation.
Can an old coil be replaced with a FACO one?
It can, if the mounting dimensions, the connection positions, the fluid and the thermal output match. An equivalence is confirmed from the data: send us the sketch or the photo of the old coil, the process data and the existing materials, and we check feasibility before the quotation.
What do I need to send for a quotation on a dry cooler?
Send the fluid cooled and the glycol concentration, the thermal load, the inlet and outlet temperatures, the design ambient air temperature, the noise limit, the desired orientation (horizontal or V-type) and the siting conditions: indoor, outdoor or an area with an explosive atmosphere.
How do I request a FACO quotation?
Send the FACO code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: FACO S.p.A. (manufacturer documentation)