Flow Management Devices supplier in Romania
FMD small volume provers for verifying liquid meters
Founded in 2007 · Headquarters: Phoenix, Arizona, USA
Who is Flow Management Devices and what does it make?
Flow Management Devices (FMD, also known as Flow MD) is an American company from Phoenix, Arizona, founded in 2007 and specialized in a single type of equipment: small volume provers for verifying liquid meters. A prover is a device with a traceable reference volume, used to determine the K factor and the meter factor of a flow meter under actual operating conditions, without taking it off the line.
The standard series goes from FMD-007 to FMD-200, with flow rates from 700 to 20,000 GPM (about 4,500 m³/h for the FMD-200EV) and flanges from 3 to 20 inches. The EV versions (060EV, 090EV, 200EV) have an extended displaced volume, useful for ultrasonic and Coriolis meters, which need a longer measuring time between detectors. The design follows API MPMS chapter 4.2, and the construction ASME VIII Div. 1; versions for Ex zones are available, as per the manufacturer's documentation. For liquefied natural gas there are cryogenic versions, with product temperature down to -195 °C.
Devices of this type matter where a petroleum product or crude oil meter is the basis for billing: terminals and depots, tanker loading stations, refineries, crude oil and refined product pipelines. A compact prover can replace a ball prover where space or downtime is limited.
What do we supply from the Flow Management Devices range?
| Product | Description |
|---|---|
| Small volume provers FMD-007 … FMD-200 | Standard series of piston provers, from 3 to 20 inches, for turbine, helical, positive displacement, ultrasonic and Coriolis meters. They are chosen by the maximum flow and the displaced volume required by the meter being proved. |
| EV line (FMD-060EV, FMD-090EV, FMD-200EV) | Extended volume provers, with a primary volume of 75–210 gallons and flow rates of 8,500–28,500 barrels/hour. More time between detectors, hence more stable results with ultrasonic and Coriolis meters or with helical turbines. |
| Cryogenic provers for LNG | Version with 316L stainless steel wetted parts, dry nitrogen purge, redundant temperature instrumentation and thermal insulation of the main components. The product can reach -195 °C. |
| Provers for special applications | Configurations for custody transfer pipelines, FPSO and platforms, renewable fuels, mass measurement and liquid CO₂, with material options and protection for Ex zones. |
Why Flow Management Devices?
- Range of sizes from FMD-007 to FMD-200, for 3–20 inch flanges — the same type of device for small stations and for large pipelines
- EV versions with extended volume (060EV, 090EV, 200EV) — flight time of 0.8–1.0 s, required for ultrasonic and Coriolis meters
- Wide temperature range: standard -29…49 °C, high up to 260 °C, cryogenic down to -101 °C and the LNG version down to -195 °C
- Design to API MPMS ch. 4.2 and ASME VIII Div. 1, with approvals for explosive atmosphere areas as per the manufacturer's documentation
- Replacement for a ball prover — smaller footprint, no sphere change for different products and water-draw calibration of the reference volume in a day or two
Which Flow Management Devices codes and series are requested most often?
| Code | Description |
|---|---|
| FMD-007 | Small volume prover, standard series |
| FMD-015 | Small volume prover, standard series |
| FMD-025 | Small volume prover, standard series |
| FMD-035 | Small volume prover, standard series |
| FMD-045 | Small volume prover, standard series |
| FMD-060 | Small volume prover, 6,000 GPM (about 1,350 m³/h) |
| FMD-060EV | Extended volume prover, 8,500 BPH |
| FMD-090 | Small volume prover, 9,000 GPM |
| FMD-090EV | Extended volume prover, 12,850 BPH |
| FMD-130 | Small volume prover, standard series |
| FMD-200 | Small volume prover, 20,000 GPM |
| FMD-200EV | Extended volume prover, 28,500 BPH |
Where is Flow Management Devices equipment used?
- Petroleum product terminals and depots — meter verification at loading and unloading
- Refineries — metrological control on product and crude oil streams
- Crude oil and refined product pipelines — custody transfer stations
- LNG terminals and liquefied gas stations — proving at cryogenic temperatures
- Offshore platforms and FPSO — compact metering installations
How do we supply Flow Management Devices in Romania?
We prepare quotations for FMD provers and for their spare parts and accessories, according to the installation data. The devices are supplied to order, and the lead time depends on the size and the configuration: provers configured for a project may take longer, depending on the specification. For a correct quotation we need: the type and diameter of the meter being proved, the minimum and maximum flow, the product with its density and viscosity, the working pressure and temperature, the required standards (ATEX, API) and whether the prover is fixed or mobile. The exact lead time is confirmed in the quotation.
On-site work on provers is outside our offer; we supply the equipment.
Frequently asked questions about Flow Management Devices
What products does Flow Management Devices make?
The company from Phoenix, Arizona, builds small volume provers for verifying liquid flow meters: a piston of known volume that establishes the K factor and the meter factor under real conditions. The range goes from FMD-007 to FMD-200, with EV versions for extended volume and cryogenic versions for LNG.
How do I choose the size of an FMD prover?
The main criterion is the maximum flow of the meter being proved, then its type: helical turbines need more pulses per pass, while ultrasonic and Coriolis meters need a flight time of 0.8–1.0 s, which is why the EV versions are chosen. To identify the suitable version we need the meter and product data.
Do you supply FMD provers in Romania, and in what time?
Yes, FMD provers are supplied to order, depending on the configuration. For parts and accessories the usual lead time is 1–4 weeks; a complete prover, configured to a project, may have a longer lead time, confirmed in the quotation after the configuration is checked.
Can an FMD prover replace an existing ball prover?
Technically it is a common option, because it takes up less space and does not require changing the sphere for different products. To say whether it fits in your station we need the line sketch, the diameter, the flow, the products measured and the meter type.
What should I send for a quotation for a prover?
Send the flange diameter and class, the minimum and maximum flow, the product (crude oil, refined product, LPG, LNG), the density and viscosity, the working pressure and temperature, the meter type and the Ex requirements. If you are replacing an existing device, add the model from the nameplate.
How do I request a Flow Management Devices quotation?
Send the Flow Management Devices code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Flow Management Devices (manufacturer documentation)