Georg Fischer supplier in Romania
For Georg Fischer we quote plastic ball valves (Type 375, Type 546 Pro), Type 565 and 567 plastic butterfly valves, and PVC-U, PP and PE piping systems; we quote against the type code.
Founded in 1802 · Headquarters: Schaffhausen, Switzerland
Who is Georg Fischer and what does it make?
Georg Fischer is a Swiss industrial group founded in 1802 in Schaffhausen, organised today in several global divisions, of which GF Piping Systems is the one relevant to industrial fluid installations — complete piping systems, valves and fittings in plastics for conveying water, chemicals and gases. In a segment where metal was for a long time the default standard, GF has built over decades an alternative in PVC, PP, PE and PVDF that solves exactly the problem metal is vulnerable to: corrosion caused by acids, bases and water with a high mineral content.
The range covers practically any combination of material and application — PVC-U and PVC-C for water and mildly aggressive chemicals, polypropylene (PP) for laboratories and water treatment, polyethylene (PE) for buried water and gas networks, and PVDF for aggressive chemical media in the semiconductor and pharmaceutical industries. The Type 514/515/517 diaphragm valves and the Type 546 Pro and 375 ball valves are designed specifically for plastic bodies, with the same leak-free sealing philosophy as the metal versions, but without the risk of internal corrosion. The COOL-FIT system, with pre-insulated pipe, is intended for coolant networks in the food and pharmaceutical industries, where heat losses and condensation on uninsulated pipes are a costly problem.
The joining method depends on the material and the diameter and is confirmed from the GF documentation. For process monitoring, the Signet range of flow, pH, conductivity and level sensors integrates directly into the plastic pipe, without additional corrosion points. GF Piping systems are found in water and wastewater treatment, the semiconductor industry, pharmaceuticals, the food industry and chemical plants — wherever the low weight, corrosion resistance and lower installation cost of plastic weigh more than the superior mechanical strength of metal.
What do we supply from the Georg Fischer range?
| Product | Description |
|---|---|
| PVC-U, PP and PE Piping Systems | The basic GF Piping Systems range covers pipes, fittings and connectors in PVC-U for drinking water and mildly aggressive chemicals, polypropylene for laboratories, the food industry and water treatment plants, and polyethylene for buried water and gas networks. Diameters range from a few millimetres for laboratory installations to a few hundred millimetres for industrial process pipes, with nominal pressures usually between PN10 and PN16, depending on material and temperature. The joining method depends on the material and the diameter and is confirmed from the GF documentation. |
| Plastic Diaphragm Valves and Ball Valves | Diaphragm valves (Type 514, 515, 517/317) use an elastomeric membrane that completely isolates the actuating mechanism from the fluid, with no dead zones where deposits or bacteria could accumulate — an important requirement in the food and pharmaceutical industries. The 546/375 series ball valves offer full bore and minimal pressure loss, with a PVC-U, PP or PVDF body for compatibility with various chemicals. Type 546 Pro ball valves cover DN10–DN100, and Type 514/515/517/317 diaphragm valves cover DN15–DN150, with manual, pneumatic or electric actuation, and are available with position sensors for integration into automated process systems. |
| COOL-FIT Pre-Insulated System for Coolant | COOL-FIT is a pre-insulated plastic piping system designed for distributing coolant, glycol water or brine in the food and pharmaceutical industries and in large commercial buildings. The integrated insulation eliminates condensation on the outer surface of the pipe, a frequent and costly problem with metal systems that are not properly insulated, and reduces heat losses along the route compared with a pipe insulated separately on site. Prefabricated installation, with fittings and bends already insulated at the factory, shortens installation time and removes the variability in the quality of manually applied insulation, an important advantage on sites with tight deadlines. |
| Signet Instrumentation Systems | The Signet range of sensors for flow, pH, conductivity, turbidity and level is designed for mounting directly in the GF plastic pipe, without additional adapters that would introduce new corrosion or leak points. Flow sensors work on the paddlewheel or electromagnetic principle, depending on the application, with 4-20mA or digital outputs for integration into the installation's existing automation. Designed specifically for process systems in the water, chemical and food industries, they offer a single monitoring solution without the need for separate instrumentation fitted invasively on the pipe by drilling and metal adapters. |
Why Georg Fischer?
- Range of plastics — PVC-U, PVC-C, PP, PE and PVDF for any level of chemical aggressiveness of the fluid
- Corrosion resistance — plastics do not corrode like metals in contact with aggressive water or chemicals
- Joining methods specific to each material — the choice is confirmed from the GF documentation
- Pre-insulated COOL-FIT system — reduces heat losses and condensation on coolant networks in the food and pharma industries
- Integrated Signet sensors — flow, pH and conductivity measurement directly in the plastic pipe, without additional corrosion points
- Low weight and quick installation — lower labour costs than equivalent steel or stainless steel systems
Which Georg Fischer codes and series are requested most often?
| Code | Description |
|---|---|
| Type 375 | Manual PVC-U ball valve, basic range |
| Type 546 Pro | Ball valve across the full range, DN10 to DN100 |
| Type 546 Pro P | Type 546 ball valve with pneumatic actuation |
| Type 546 Pro E-127 | Ball valve with electric actuation |
| Type 543 Pro | Three-way ball valve for mixing or distribution |
| Type 522 | Laboratory ball valve, minimum size DN6 |
| Type 565 | Butterfly valve with elastomeric sealing for water, DN50-DN300 |
| Type 567 | Plastic butterfly valve (PVC-U, PVC-C, PP-H, PVDF, ABS), DN50-DN600, PN10 |
| Type 578 | Plastic butterfly valve, DN50-DN300, PN10 |
| Type 514 | Diaphragm valve for standard applications, DN15-DN50 |
| Type 515 | Diaphragm valve for demanding applications, DN15-DN50 |
| Type 517/317 | Versatile diaphragm valve, DN15-DN150 |
| DIASTAR Six | Diaphragm valve for pressures up to 6 bar |
| DIASTAR Ten | Pneumatic diaphragm valve for pressures up to 10 bar |
| Type 561/562 | Check valve, DN10-DN100 |
| Type 369 | Wafer-type check valve, DN32-DN300 |
| Type 2551 | Electromagnetic insertion flow transmitter |
| Type 2581 | Integral-block flowmeter, FlowtraMag type |
| Type 2291 | Guided radar level transmitter |
| Type 2298 | Non-contact radar level transmitter |
Where is Georg Fischer equipment used?
- Water and wastewater treatment — treatment plants, desalination, municipal networks
- Semiconductor industry — transport of ultra-pure chemicals, PVDF systems
- Pharmaceutical industry — purified water, WFI, sanitary systems without dead zones
- Food and beverage industry — coolant, processing, CIP washing
- Chemical industry — transport of acids, bases and solvents in corrosion-resistant pipes
- Commercial and industrial buildings — COOL-FIT pre-insulated cooling systems
How do we supply Georg Fischer in Romania?
We help source GF Piping Systems piping systems, valves and fittings — PVC-U, PP, PE and PVDF, diaphragm and ball valves, plus the COOL-FIT pre-insulated system — for water treatment plants and chemical installations in Romania, through EU supply channels. Material compatibility is checked for each request in the manufacturer's technical documentation. For a correct recommendation, send us the fluid being conveyed and the working pressure and temperature. Common PVC-U and PP diameters and fittings can usually ship in 24–72 h when the item is in stock, locally or at the supplier, while configurations with automated valves or integrated Signet sensors usually arrive in 1–4 weeks to order.
We check the availability of each diameter and material on request; on-site welding is outside our offer.
Frequently asked questions about Georg Fischer
Which Georg Fischer plastic ball valve should I choose for a chemical line?
The Type 546 Pro valve is offered in diameters from DN10 to DN100, suited to most applications with water and chemicals compatible with PVC-U or PP. For mixing or multi-port distribution, the Type 543 Pro three-way valve is the right solution, and for automatic actuation there are the Pro P and Pro E variants.
What is the difference between Georg Fischer Type 565 and Type 567 butterfly valves?
Type 565 has elastomeric sealing and is intended for water applications, covering diameters from DN50 to DN300. Type 567 is available in several plastics (PVC-U, PVC-C, PP-H, PVDF, ABS), with an extended range from DN50 to DN600; chemical compatibility is confirmed for the chosen material.
What nominal pressure does the Georg Fischer Type 546 Pro ball valve have, depending on the material?
On the Type 546 Pro, PVC-U, PVC-C and PVDF bodies have pressure rating PN16, while ABS and PP-H bodies have PN10. The size range is d16/DN10 – d110/DN100, on some versions up to d160/DN150, with O-ring seals made of EPDM, FKM or FFKM. The exact combination of material, seal and joint is confirmed in the quotation.
What information do I send for a Georg Fischer valve quotation?
It helps to specify the nominal diameter, the pipe material (PVC-U, PP or PE), the working pressure and the type of actuation required (manual, pneumatic or electric). For process instrumentation, the required output signal type and the measured medium also matter, so that the right Georg Fischer sensor can be chosen.
How do I request a Georg Fischer quotation?
Send the Georg Fischer code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 20 November 2026 · Sources: GF Piping Systems, Georg Fischer AG (manufacturer documentation)