Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Groth Corporation supplier in Romania

For Groth we quote 1200A and 17F-TWW pressure-vacuum valves, 2000A and 2100 emergency vents, 7618 and 76E flame arresters, 7658A detonation arresters and 3000 regulators, based on the model on the nameplate and the tank data.

Headquarters: Stafford, Texas, USA

Request a quote

Who is Groth Corporation and what does it make?

Groth Corporation is an American manufacturer based in Stafford, Texas, specialized in protection equipment for low-pressure tanks and gas pipelines: pressure-vacuum valves, emergency vents, flame and detonation arresters, free vents, gauge hatches and blanketing gas regulators. Fixed-roof tanks in refineries, crude oil and petroleum product depots, chemical plants and biogas installations breathe at every filling, emptying or temperature change, and this equipment decides how much air comes in, how much vapour goes out and whether a flame from outside can reach the flammable product.

The range is organized by model. Pressure-vacuum valves from the 1200A family and the derivatives 1201B, 1202B, 1203A, 1220A–1223A and 1720A, as well as 12E-TSW, 12F-TWW-0 and 17F-TWW, protect the tank against overpressure and vacuum. Emergency vents 2000A, 2100, 2400A, 2050A, 2450A and 22E release vapours when the tank pressure exceeds the limit in emergency situations. Pilot-operated valves are 14F-TP0, 14E-TP0, 1400, 1420, 1430, 1460 and 1660A, and the valve and flame arrester combinations are 8800A, 8820A, 88F-HWW-D and 88E-HWW-C. Flame arresters include 7618, 7628, 7588, 7598 and 76E-UF, 76E-AF, and the detonation arresters 7661, 7658A and 7758A.

For refineries, petroleum product depots and chemical plants in Romania, what matters most is the gas class and the working temperature, the set pressure and vacuum, the connection and the body material, so the quotation starts from the model on the nameplate or from the tank data sheet.

What do we supply from the Groth Corporation range?

ProductDescription
1200A, 12E and 17F pressure-vacuum valvesValves for fixed-roof tanks, which limit overpressure and vacuum and reduce product losses through tank breathing. They have peripheral and central seat guides, fluoropolymer diaphragms and self-draining bodies, in aluminium, carbon steel, stainless steel or fibreglass.
2000A, 2100, 2400A, 22E emergency ventsHigh-flow safety valves, weight-loaded or spring-loaded, which release vapours when the tank pressure exceeds the set value in emergency situations. The 2050A and 2450A versions are for pressure and vacuum.
7618, 7628, 76E flame arresters and 7661, 7658A, 7758A detonation arrestersFlame arresters with a crimped ribbon element protect gas pipelines and tanks with flammable liquids, in versions for vertical, horizontal, in-line and end-of-line mounting, some with ATEX versions according to the manufacturer's documentation (for potentially explosive atmospheres). The 7658A and 7758A detonation arresters are for group D and groups C and D gases respectively.
Pilot-operated valves, combinations and 3000 regulatorsPilot valves 14F-TP0, 14E-TP0, 1400, 1420, 1430, 1460 and 1660A work with set pressures close to the tank limit. The 8800A and 8820A combinations bring together the valve and the flame arrester, and the 3000 series regulates the blanketing gas.

Why Groth Corporation?

  • Range organized by model — pressure-vacuum, emergency and pilot-operated valves, in aluminium, carbon steel, stainless steel and fibreglass designs
  • Flame and detonation arresters — 7618 and 7628, as well as 7588 and 7598 (with ATEX versions according to the manufacturer's documentation), 76E-UF and 76E-AF, 7661, 7658A (group D) and 7758A (groups C and D)
  • Valve and flame arrester combinations — 8800A, 8820A, 88F-HWW-D and 88E-HWW-C for tanks that need both functions in a single unit
  • Flow and flame testing in the manufacturer's laboratories — a flow laboratory to ASME PTC-25 and a deflagration laboratory with tests to ISO 16852
  • 3000 series blanketing gas regulators — for keeping the blanketing gas above the product in the tank

Which Groth Corporation codes and series are requested most often?

CodeDescription
1200APressure-vacuum valve for tanks
1220APressure-vacuum valve with piped discharge
12E-TSWSpring-loaded pressure-vacuum valve
17F-TWWWeight-loaded pressure-vacuum valve
2000AEmergency pressure vent, weight-loaded
2100Emergency pressure vent, spring-loaded
22EEmergency vent
14F-TP0Pilot-operated safety valve
1400Pilot-operated valve with vacuum breaker
7618Flame arrester for vertical mounting
7628Flame arrester for horizontal mounting
7588In-line vertical flame arrester, with versions for explosion-risk zones
76E-UF / 76E-AFFlame arrester for low-pressure tanks and gas pipelines
7658ADetonation arrester for group D gases
8800APressure-vacuum valve with flame arrester
3000 SeriesBlanketing gas regulators

Where is Groth Corporation equipment used?

  • Refineries — fixed-roof tanks for crude oil and petroleum products
  • Oil and gas — depots, loading stations and gas pipelines
  • Chemicals and petrochemicals — tanks for solvents and other flammable liquids
  • Biogas — pipelines and tanks with flame protection
  • Food, pharmaceutical and water treatment — protection of process tanks

How do we supply Groth Corporation in Romania?

We can quote Groth products for the protection of tanks and gas pipelines: pressure-vacuum valves, emergency vents, pilot-operated valves, flame and detonation arresters, free vents and blanketing gas regulators, supplied to order. The supply lead time is usually 1–4 weeks; large sizes, special materials and certifications can extend it. For a correct quotation send us the model on the nameplate, the connection diameter, the set pressure and vacuum, the product stored or the gas group, the material and whether ATEX certification is needed.

The set pressure and the gas group of an arrester are confirmed from the tank data and the product stored; the certifications required are established on the specific model.

Frequently asked questions about Groth Corporation

What does Groth Corporation make?

Groth, based in Stafford, Texas, makes protection equipment for low-pressure tanks: pressure-vacuum valves, emergency vents, pilot-operated valves, flame and detonation arresters, free vents, gauge hatches and blanketing gas regulators. Models are recognized by the numeric code on the nameplate, for example 1200A, 2000A or 7618.

How do I choose between a pressure-vacuum valve and an emergency vent?

The pressure-vacuum valve is fitted on the tank for ordinary breathing, during filling and emptying, while the emergency vent releases vapours in emergency situations. Usually both are used. Send us the tank diameter, the design pressure and the maximum flow.

Can you supply Groth products in Romania and how long does it take?

Groth valves and arresters are supplied to order. The usual lead time is 1–4 weeks; special materials, large sizes and certifications can extend the lead time, depending on the specification. Items can ship in 24–72 h when the item is in stock, locally or at the supplier. We confirm the exact lead time in the quotation.

Can I replace an old flame arrester with a current Groth model?

This is checked from the model on the nameplate, the connection diameter, the gas group, the mounting type (vertical, horizontal, in-line or end-of-line) and the certification required. A direct replacement is confirmed after comparing these data; send the nameplate and the pipeline data.

What data do I need to send for a quotation on a Groth valve or flame arrester?

Send the model or type wanted, the connection diameter, the set pressure and vacuum, the product stored or the gas group, the temperature, the body material (aluminium, carbon steel, stainless steel) and whether a version for explosion-risk zones is needed. For existing tanks add the data from the nameplate of the installed valve.

How do I request a Groth Corporation quotation?

Send the Groth Corporation code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Groth Corporation (manufacturer documentation)