Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Heat Trace supplier in Romania

Electric heat tracing cables, thermostats and terminations for pipes

Founded in 1974 · Headquarters: Helsby, United Kingdom

Request a quote

Who is Heat Trace and what does it make?

Heat Trace Limited is a British manufacturer of electric heat tracing equipment, founded in 1974 and based in Helsby, near Frodsham, in Cheshire. Heat tracing means a heating cable fitted along a pipe or tank, under the insulation, that compensates for heat losses: it either keeps a fluid at process temperature (for example viscous crude oil or a solution that crystallises) or prevents freezing. The company is present in more than 50 countries.

The range includes three families of cables. The self-regulating ones (FailSafe Ultimo FSU, Freezstop Extra FSE, Freezstop Regular and Micro, FailSafe Super) change their output with temperature and can be cut to length on site. FailSafe Ultimo has outputs of 15–75 W/m, the wide version 100 W/m, and withstands 250 °C. Constant-wattage cables (PowerHeat PHT, 30–70 W/m, at 285 °C) can replace mineral-insulated cables. MI cables reach 800 °C and 300 W/m, and the Longline LLR series-resistance cables serve circuits of up to 60 km. The range is completed by EXd thermostats, junction boxes, terminations and DESTU sealing kits.

The need arises on outdoor pipes and tanks, steam installations, wastewater and fuel pipes, loading ramps, roofs and access ramps. The cable, the circuit and the termination must be identified together, otherwise the installation cannot be closed out correctly.

What do we supply from the Heat Trace range?

ProductDescription
Industrial self-regulating cablesFailSafe Ultimo (FSU and the wide version FSUw), Freezstop Extra and Extra Wide (FSE, FSEw), Freezstop Regular and Micro, FailSafe Super. They are cut to length on site and used for frost protection or for maintaining the temperature of pipes and vessels.
Constant-wattage and MI cablesPowerHeat (PHT and AHT), MicroTracer, MiniTracer, HeatTracer RHT and mineral-insulated cables up to 800 °C and 300 W/m, for high temperatures, steam tracing of pipes and processes above 350 °C.
Longline cablesSeries-resistance cables for long pipes, which give constant power per metre without voltage drop along the length. The round LLR version serves circuits of up to 60 km, in single-phase or three-phase connection.
Control, terminations and kitsR series thermostats and junction boxes for EXd zones, thermostats for commercial installations, standard terminations, boxes with indicator light, DESTU connections and DS1–DS4 sealing kits.

Why Heat Trace?

  • Self-regulating cables cut to length on site — the circuit adapts to the pipe length, without special design per section
  • FailSafe Ultimo, 15–100 W/m, withstands 250 °C — covers keeping process temperature on steam pipes and hot fluids
  • Constant-wattage PowerHeat PHT, up to 70 W/m and 285 °C — can be used in place of mineral-insulated cables, but can be cut to length
  • MI cables up to 800 °C and 300 W/m, and Longline LLR for circuits of up to 60 km — for long pipes or extreme temperatures
  • EXd thermostats and boxes, plus terminations and sealing kits — a complete circuit is obtained

Which Heat Trace codes and series are requested most often?

CodeDescription
FSUFailSafe Ultimo, industrial self-regulating, 15–75 W/m, 250 °C
FSUwFailSafe Ultimo Wide, self-regulating, 100 W/m
FSEFreezstop Extra, self-regulating, 17 and 31 W/m
FSEwFreezstop Extra Wide, self-regulating
FSRFreezstop Regular, industrial self-regulating
FSMFreezstop Micro, industrial self-regulating
FSSFailSafe Super, industrial self-regulating
PHTPowerHeat, constant wattage, 30, 50 and 70 W/m, 285 °C
LLRLongline Round, series resistance, circuits of up to 60 km
FLVwFreezstop Low Voltage Wide, low voltage
R130/JBSTJunction box with EXd thermostat
R100/EOL/RTermination box with indicator light

Where is Heat Trace equipment used?

  • Oil and gas — overhead and buried pipes, maintaining fluid temperature
  • Process industry — tanks, vessels and instrumentation lines
  • Waste-to-energy — pipes and equipment at risk of freezing
  • Rail transport — heating of points and winter protection
  • Buildings and agriculture — pipes, gutters, roofs and fuel tanks

How do we supply Heat Trace in Romania?

We can quote Heat Trace heat tracing cables, plus terminations, boxes and thermostats, based on the circuit design or the code on the existing cable. We supply to order; for standard cables and accessories the lead time is usually 1–4 weeks, and for large reels, MI cables or long circuits it can be longer. For a correct quotation we need the pipe diameter and length, the insulation thickness, the maintenance temperature and the minimum ambient temperature, the output required in W/m, the voltage, the temperature class and the zone (EXd or normal). The exact lead time appears in the quotation.

A complete heat tracing circuit is sized from the pipe and insulation data, and the detailed design stays with the installation's designer.

Frequently asked questions about Heat Trace

What does Heat Trace make?

Heat Trace Limited, founded in 1974 in Helsby (Cheshire), manufactures electric heat tracing equipment: self-regulating, constant-wattage, mineral-insulated and Longline cables, plus thermostats, junction boxes and terminations for frost protection and temperature maintenance.

How do I choose between a self-regulating cable and a constant-wattage cable?

A self-regulating cable reduces its output as the pipe warms up and is cut to length, so it suits variable circuits up to 250 °C. A constant-wattage cable, such as PowerHeat, reaches 285 °C and up to 70 W/m. Send the maintenance temperature and the pipe data.

Can you supply Heat Trace cables in Romania, and within what lead time?

Products are supplied to order. Standard cables and accessories usually have a lead time of 1–4 weeks, and large reels, MI cables or long circuits can take longer. The exact lead time appears in the quotation.

Can I replace an existing heating cable with a Heat Trace one?

Only after comparing the type (self-regulating, constant or MI), the power per metre, the voltage, the maximum temperature and the terminations. Equivalences are confirmed on the basis of these data. Send the cable marking, a photo of the termination and the circuit length.

What information do you need for a quotation on a heat tracing circuit?

The pipe diameter and length or the tank dimensions, the insulation thickness and type, the maintenance temperature and the minimum ambient temperature, the voltage, the classified zone and the number of circuits. If there is a design, send the circuit diagram.

How do I request a Heat Trace quotation?

Send the Heat Trace code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Heat Trace Ltd (manufacturer documentation)