Heron Instruments supplier in Romania
For Heron Instruments we offer the dipper-T2, dipper-Tough and Water Tape level probes, the H.OIL interface probe, conductivity+ and dipper-Temp, the dipper-See camera and dipper-Log dataloggers, based on the series, the tape length and the pressure range.
Headquarters: Dundas, Canada
Who is Heron Instruments and what does it make?
In Dundas (Ontario), Heron Instruments makes field instruments for groundwater monitoring: level probes with graduated tape, oil–water interface probes, conductivity and temperature probes, borehole inspection cameras and level loggers (dataloggers) with a pressure sensor. The level probes have a tape with a stainless steel core and a polymer coating, marked in metric scale or in hundredths of a foot, and a 16 mm IP68 probe that signals contact with water by sound and light.
The dipper-T2 series measures the depth to water and allows the drawdown to be followed during pumping; LongLiner has an electric motor and tapes of up to 1200 m, while dipper-Tough has the tape embedded in the probe, for aggressive media. The H.OIL probe from the 1600 series has intrinsically safe variants, according to the manufacturer's documentation, and distinguishes floating product (LNAPL) from sinking product (DNAPL), in layers down to 1 mm. The dipper-Log loggers measure level and temperature with a typical accuracy of ±0.05 % of full scale and operate between −20 and 80 °C. The dipper-Temp series profiles temperature between −45 and 135 °C, and conductivity+ displays conductivity up to 250,000 µS.
Such instruments are used in observation well networks, at industrial sites under remediation, at landfill sites and at stations with fuel tanks. The offer starts from the tape length, the probe type, the measured medium and, for loggers, the pressure range and the vented or absolute variant.
What do we supply from the Heron Instruments range?
| Product | Description |
|---|---|
| dipper-T2 (series 1200), dipper-Tough (1400), Water Tape (1900), SKINNY DIPPER (1300) | Level probes with graduated tape for measuring the depth to water, with an electronic panel with sound and light signal. dipper-Tough has the tape embedded in the probe and a Kynar coating, for aggressive media, and SKINNY DIPPER has a 6.5 mm tape and probe, for narrow piezometers. |
| H.OIL (series 1600) and Leachate+ (series 3000) | H.OIL measures the interface between two liquids and signals water, LNAPL and DNAPL differently, with intrinsic safety. Leachate+ has a shielded 24.5 mm probe for landfill leachate, avoiding false readings caused by foam or deposits. |
| conductivity+ (series 1700) and dipper-Temp (series 1800) | conductivity+ displays conductivity up to 250,000 µS and temperature between −20 and 70 °C, useful for saltwater intrusion. dipper-Temp profiles temperature from −45 to 135 °C, with an accuracy of ±0.05 °C, and also works as a level probe. |
| dipper-Log Tough+, dipper-Log 128+, dipper-Log Vented+ and barLog | Level, pressure and temperature loggers for groundwater, with ranges of 10, 30, 60 or 120 m of water column, typical accuracy ±0.05 % of full scale and 128,000 data sets. The vented variant compensates for atmospheric pressure, and barLog measures barometric pressure. |
Why Heron Instruments?
- Level probe with permanently marked tape — the tape has a stainless steel core and a polyethylene or Kynar coating, resistant to stretching
- Oil–water interface probe in a version for explosive atmospheres, according to the manufacturer's documentation — H.OIL detects layers of 1 mm
- Tape of up to 1200 m on the motorised model — LongLiner reduces the effort of measuring deep wells
- Loggers with a titanium or 316 steel sensor — dipper-Log Tough+ and 128+ store 128,000 data sets, with a battery life of up to 15 years, depending on use
- Temperature and conductivity probe on the same tape — conductivity+ reads up to 250,000 µS, which helps detect saltwater intrusion
Which Heron Instruments codes and series are requested most often?
| Code | Description |
|---|---|
| 1202 | dipper-T2, level probe with field-replaceable probe |
| 4002 | LongLiner, motorised level probe, tape 450–1200 m |
| 1402 | dipper-Tough, level probe for aggressive media |
| 1902 | Water Tape, level probe with polyethylene tape |
| 1302 | SKINNY DIPPER, level probe with 6.5 mm tape and probe |
| 1500 | dipper-Tag, probe with acoustic level detection |
| 1602 | H.OIL, oil–water interface probe, intrinsically safe |
| 1702 | conductivity+, level, temperature and conductivity |
| 1802 | dipper-Temp, level and temperature, −45…135 °C |
| 3000 | Leachate+, probe for landfill leachate |
| 2000 | dipper-See EXAMINER, borehole inspection camera |
| dipper-Log 128+ | Absolute level, pressure and temperature logger |
| dipper-Log Vented+ | Vented level, pressure and temperature logger |
| barLog | Barometric pressure logger |
Where is Heron Instruments equipment used?
- Hydrogeology and water boreholes — measuring the static level and the drawdown during pumping
- Remediation of contaminated sites — detecting floating and sinking petroleum products
- Landfills — measuring the leachate level in monitoring wells
- Oil, gas and petrochemicals — oil–water interface in explosive atmospheres
- Coastal areas — detecting saltwater intrusion by conductivity
How do we supply Heron Instruments in Romania?
From the Heron range we can offer tape level probes, oil–water interface probes, conductivity and temperature probes, dipper-See cameras and dipper-Log dataloggers, supplied to order. The equipment is supplied to order, usually in 1–4 weeks, and the lead time may be longer depending on the specification. The request for quotation should include the series (for example 1202 or 1602), the tape length in metres or feet, the probe type and the measured medium; for loggers, add the pressure range and the vented or absolute variant. Spare parts are identified by the part number on the tape or on the panel.
Repairs and recalibration of the probes are outside our equipment offer.
Frequently asked questions about Heron Instruments
What does Heron Instruments make?
Heron Instruments makes field instruments for groundwater: tape level probes, oil–water interface probes, conductivity and temperature probes, borehole inspection cameras and level loggers with a pressure sensor. The headquarters are in Dundas, Ontario, Canada.
How do I choose the tape length and the type of level probe?
The tape length must exceed the maximum depth of the well with a margin, and the type is chosen by medium: polyethylene for clean water, Kynar coating for temperatures or aggressive substances, a motor for great depths. Tell us the depth, the well diameter and the liquid, and we will check the suitable series.
Can Heron equipment be brought to Romania, and how fast?
The equipment is brought in to order, usually in 1–4 weeks; it can ship in 24–72 h when the item is in stock, locally or at the supplier. Depending on the specification, the lead time may be longer, and the exact value appears in the quotation.
Can I replace the tape or the probe of an older Heron instrument?
The replacement tape and the detachable probe are ordered by the instrument series and the tape length, and the quick-connect (link) parts must match the electronic panel. Send a photo of the nameplate and the length; we check, before quoting, whether the current part fits.
What data should I send for a quotation on a dipper-Log level logger?
Send the maximum immersion depth, so that we can set the range of 10, 30, 60 or 120 m, whether you want a vented or absolute variant, the mounting method (suspended, with direct cable or on a reel) and whether you need a barometric logger for compensation.
How do I request a Heron Instruments quotation?
Send the Heron Instruments code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Heron Instruments Inc. (manufacturer documentation)