Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Hydac HYDAC D / DN (Betamicron pressure filter elements)

HYDAC type D and DN pressure filter elements with Betamicron BN4HC or BH4HC material, filtration rating 3–25 µm, for pressure filters in hydraulic installations.

D and DN elements are the HYDAC filter elements for pressure filters: D is the HYDAC pressure element, and DN is the pressure element to the DIN 24550 specification. The manufacturer's datasheet describes them with Betamicron material: BN4HC (Betamicron-N, low collapse resistance) and BH4HC (Betamicron-H, high collapse resistance). Flow is from outside to inside, the elements are disposable, and the temperature range is -30 … +100 °C.

The order code has the structure from the datasheet, for example "0660 D 005 BH4HC /V SO263": the size (0660), the element type (D or DN), the filtration rating in µm (005), the material (BH4HC or BN4HC), the seal (no letter = NBR, V = FKM) and additional details (for example SO263 for phosphate ester fluids of the Skydrol or HYJET type). For a quotation, please send us the complete code from the element or from the filter housing; codes with a material other than Betamicron (for example ON) are checked separately, in the corresponding HYDAC documentation.

Models and codes

CodeNote
0160 D 005 BH4HCBetamicron-H, 5 µm, NBR seal; in the HYDAC catalogue: outside diameter 69 mm, length 115 mm, inside diameter 34 mm, collapse resistance 210 bar.
0660 D 005 BH4HC /V SO263the code example from the datasheet: size 0660, 5 µm, Betamicron-H, FKM seal, design for Skydrol or HYJET fluids.
0240 DD element size from the datasheet list; the rating, material and seal are read from the complete code.
0330 DD element size from the datasheet list; the rating, material and seal are read from the complete code.
0110 DD element size from the datasheet list; the rating, material and seal are read from the complete code.
0160 DNDN element size (DIN 24550) from the datasheet list; the rating and material are read from the complete code.

Key specifications

D sizes0030, 0035, 0055, 0060, 0075, 0095, 0110, 0140, 0160, 0240, 0280, 0330, 0500, 0660, 0990, 1320, 1500
DN sizes (DIN 24550)0040, 0063, 0100, 0160, 0250, 0400, 0630, 1000
Filtration ratingBH4HC: 3, 5, 10, 20 µm; BN4HC on DN elements: 3, 6, 10, 25 µm (general datasheet: 3, 5, 10, 20 µm)
Collapse resistance210 bar for D with BH4HC; 20 bar for D/DN with BN4HC
Bypass valve (standard)D…BN: 6 bar; D…BH: no bypass
Temperature range-30 … +100 °C
Flow directionfrom outside to inside
SealsNBR (standard, no letter in the code); FKM (V)
Additional designsSO263 (Skydrol / HYJET fluids), SFREE (reduced electrostatic charge generation), SO376 (fire-resistant fluids HFA, HFB, HFC, HFD, on ON and W/HC elements)

The HYDAC datasheet "Filter Elements — Betamicron® Series" (PN#02081318, edition 04.26) is current on the manufacturer's website, with no withdrawal notice; the element 0160 D 005 BH4HC appears in the HYDAC online catalogue.

Frequently asked questions

How do I read "0160 D 010 BN4HC"?

0160 is the element size, D the type (HYDAC pressure element), 010 the filtration rating in µm, and BN4HC the Betamicron-N material. The absence of the letter V after the material means an NBR seal. We check the exact combination in the HYDAC documentation before the quotation.

What is the difference between BN4HC and BH4HC?

Both are Betamicron materials. The HYDAC datasheet gives for BH4HC (Betamicron-H) a collapse resistance of 210 bar on D elements and no standard bypass, and for BN4HC (Betamicron-N) 20 bar and a 6 bar bypass on D…BN.

What data do I send for a quotation?

The complete code from the element (size, type, rating, material, seal and any suffix), the working fluid and, if you have it, the filter housing code.

Other Hydac series

The dimensions, flows and pressure drops for each size are read from the HYDAC documentation for the exact code; the table gives the dimensions of a single element only (0160 D 005 BH4HC), taken from the manufacturer's catalogue.

Updated: 2026-11-23