IMI CCI supplier in Romania
DRAG® control valves, steam conditioning valves and desuperheaters
Who is IMI CCI and what does it make?
IMI CCI specialises in control valves for severe service, in power plants, oil and gas and petrochemicals. It starts from the DRAG® technology, introduced in 1967 to solve cavitation, vibration and noise in severe-service valves. The principle is to reduce the pressure drop in several stages, so that the fluid velocity stays below the threshold at which cavitation and erosion occur.
The 100D DRAG series is a multi-stage, multi-turn control valve for high pressure drops; the 860 series is an angle valve, for general and severe service, with top maintenance, while the 840 and AB200 cover general control, the AB200 for low and medium pressures, up to ANSI Class 600. For steam, the VLB is a conditioning valve with several pressure-reduction stages and a desuperheating stage by water injection, for turbine bypass, and the NBSE is a low-pressure bypass for ultra-supercritical plants. The two-stage DAM-D desuperheater replaces thermal liners. Newer technologies are Metamorphic Trim, EroSolve and Retrofit3D.
The practical interest is in thermal power plants, combined-cycle plants, refineries and gas installations, where a control valve with cavitation or noise has to be replaced or modernised. A correct quotation starts from the process data and from the drawing of the existing valve. For power plants there is also a seat upgrade (Q1 Seat Upgrade) for the VLB and VLR valves.
What do we supply from the IMI CCI range?
| Product | Description |
|---|---|
| 100D DRAG® | Multi-stage, multi-turn control valve for high pressure drops, with a DRAG® trim that reduces cavitation, noise and erosion; customised for the application. |
| Series 860, 840 and AB200 | The 860 is an angle valve for general and severe service, with optional DRAG® trim and top maintenance; the 840 is the single-stage version, cage-guided; the AB200 is a valve for low and medium pressures, up to ANSI Class 600. |
| VLB and NBSE | Steam conditioning valves for turbine bypass: the VLB, in an angle design, with pressure-reduction stages and desuperheating by injected water; the NBSE, for LP bypass in ultra-supercritical plants, with fast response. |
| DAM-D | Desuperheater with a manifold, with two stages: perforated cylinders for pressure reduction and spring-loaded atomising nozzles for water distribution; it reduces noise and vibration in the steam line. It can be customised for large capacities and high temperatures. |
Why IMI CCI?
- Multi-stage DRAG® technology — introduced in 1967, for high pressure drops with reduced cavitation, vibration and noise
- Steam conditioning in a single valve — the VLB combines several pressure-reduction stages and a desuperheating stage
- Low-pressure bypass for ultra-supercritical plants — NBSE, with a noise-absorbing cage and spring-loaded water nozzles
- DAM-D desuperheater — pressure reduction and temperature control, without thermal liners
- Upgrades — Q1 Seat Upgrade for VLB and VLR, Retrofit3D and anti-erosion trims
Which IMI CCI codes and series are requested most often?
| Code | Description |
|---|---|
| 100D | DRAG® multi-stage, multi-turn control valve |
| 860 Series | Angle valve for general and severe service |
| 840 Series | Single-stage, cage-guided valve |
| AB200 | Control valve for low and medium pressures, up to Class 600 |
| VLB | Steam conditioning valve, angle design |
| VLR | Valve from the VLB family, with Q1 Seat Upgrade |
| NBSE | LP turbine bypass valve for ultra-supercritical plants |
| DAM-D | Desuperheater with manifold, two stages |
| Metamorphic Trim | Trim technology for severe service |
| EroSolve | Anti-erosion solution |
| Retrofit3D | Upgrade solution for existing valves |
Where is IMI CCI equipment used?
- Thermal and combined-cycle power plants — turbine bypass, feedwater, steam conditioning
- Oil and gas — control valves for severe service
- Petrochemicals — control with a high pressure drop
- Plant start-up and shutdown — valves for transient regimes
- Upgrades — anti-cavitation and anti-erosion trims on existing valves
How do we supply IMI CCI in Romania?
We can quote IMI CCI control valves from the 100D, 840, 860, AB200, VLB, NBSE series and DAM-D desuperheaters, as well as upgrade components. Supplied to order; for severe-service valves configured to the process, the lead time can be longer, depending on the specification. For a correct quotation, send the series and nameplate of the existing valve, the fluid, the flow, the inlet and outlet pressures, the temperature, the noise permitted and the actuator type. We check the trim from the process data.
The number of DRAG® stages and the materials are selected at the factory from the process data, and a replacement is checked remotely from that data.
Frequently asked questions about IMI CCI
What does IMI CCI make?
IMI CCI makes severe-service control valves (100D DRAG®, 860, 840, AB200), steam conditioning valves (VLB, NBSE), desuperheaters (DAM-D) and upgrade solutions. They are used in power plants, oil and gas and petrochemicals.
How do I choose between a 100D DRAG® valve and one from the 860 series?
The 100D is a multi-stage, multi-turn valve, designed for very high pressure drops; the 860 is a more versatile angle valve, with optional DRAG® trim and top maintenance. Send the flow, the inlet and outlet pressures and the fluid, so that we can check the suitable stage.
Do you supply IMI CCI products in Romania and how fast?
Yes, IMI CCI products are supplied to order. A standard valve can be supplied to order, usually in 1–4 weeks, but severe-service valves are configured to the process and have a longer lead time, set in the quotation once we receive the process data.
Can I upgrade an existing VLB or VLR valve?
For VLB and VLR there is a Q1 Seat Upgrade, but compatibility depends on the series and age of the valve. A fit is confirmed from data, not from the name: send the nameplate of the valve, the drawing and the process data, and we check the fit before the quotation.
What do I need to send for a quotation on a severe-service control valve?
The fluid and its state (liquid, gas, steam), the minimum and maximum flow, the inlet and outlet pressures, the temperature, the diameter and class, the phenomena encountered (cavitation, flashing, noise, erosion), the material and the actuator type. Add the noise permitted in the pipe.
How do I request a IMI CCI quotation?
Send the IMI CCI code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: IMI Process Automation (manufacturer documentation)