Jefferson supplier in Romania

For Jefferson we quote 2-way solenoid valves from the 1314, 1327, 1330 and 1342 series, general-purpose 2036 solenoid valves, 3-way and 4-way versions, and solenoid valves for fuel gas, for combustion and for cryogenic UC use; the item is identified by the series and the order code.

Request a quote

Who is Jefferson and what does it make?

Jefferson is a manufacturer of solenoid valves, with a range divided into four lines: general purpose, combustion, 3-way and 4-way, and special services. The series are identified by a number, for example 1314, 1327, 1330 or 1342, and suffixes indicate versions such as UC, for cryogenic use, or CL, for slow closing. The applications are those where an electrical signal has to open or close the flow of a fluid: water, air, steam, liquid and gaseous fuels.

Series 1314 is a 2-way, normally closed, pilot-operated solenoid valve, with a bronze or stainless steel body, BSP or NPT threaded connection and sealing depending on the fluid, in Buna N, EPDM, neoprene, FKM or PTFE. It is used for recirculation pumps, steam heating, laundries, irrigation, air dryers, water treatment and vacuum systems. Series 1330 and 2030 are 2-way solenoid valves for fuel gas and other gases, normally closed or normally open, direct-acting or pilot-operated, with a cast aluminium body. The series with the UC suffix are for cryogenic fluids, for example oxygen, argon, liquid nitrogen and liquid CO2, with a brass or bronze body and PTFE seals, at temperatures from −200 °C to 50 °C.

Series 1342CL is designed for slow closing, which reduces water hammer. The range also includes applications for steam and hot water, gas, CNG, diesel, heavy fuel oil, manual reset and filters. For a quotation, the series, fluid, differential pressure, coil voltage and connection matter.

What do we supply from the Jefferson range?

ProductDescription
Series 1314, general purpose2-way, normally closed, pilot-operated solenoid valve, with a bronze or stainless steel body, BSP or NPT thread. Used for water, air, steam and other fluids, with sealing chosen by fluid and with explosion-proof enclosure options.
Series 1330 and 2030, fuel gas2-way solenoid valves for fuel gas and other gases, normally closed or open, direct-acting or pilot-operated. Cast aluminium body and BSP or NPT connections. On series 2030, closing takes less than a second.
UC series, cryogenic useThe UC versions of series 1314, 1327 and 1390 are for oxygen, argon, nitrogen and liquid CO2. PTFE seals, cleaned and oil-free, with an operating temperature from −200 °C to 50 °C.
Series 1342CL, slow closingSolenoid valve designed to reduce water hammer, in normally closed and normally open versions. Used for water and low-viscosity liquids, in high-velocity or long pipelines.

Why Jefferson?

  • Series in four lines: general purpose, combustion, 3-way and 4-way, and special services: start from the type of application
  • Versions with Buna N, EPDM, neoprene, FKM or PTFE sealing: the fluid and temperature dictate the material
  • UC series for oxygen, argon, nitrogen and liquid CO2: cryogenic fluids have dedicated versions
  • Series 1342CL with slow closing: water hammer is reduced in long pipelines
  • Solenoid valves for fuel gas, diesel and heavy fuel oil: the same family covers combustion circuits

Which Jefferson codes and series are requested most often?

CodeDescription
13142-way, general-purpose, normally closed, pilot-operated solenoid valve
13272-way, general-purpose solenoid valve
13422-way, general-purpose solenoid valve
1342CLSlow-closing solenoid valve, against water hammer
1390General-purpose solenoid valve
2036Solenoid valve from the general-purpose range
1330Fuel gas solenoid valve, direct-acting or pilot-operated
2030Solenoid valve for fuel gas and other gases
1388Combustion solenoid valve, normally closed
1323Solenoid valve from the 3-way and 4-way line
1350Solenoid valve from the 3-way and 4-way line
1314-UCCryogenic version, fluids from −200 °C to 50 °C
1327-UCCryogenic version for oxygen, argon, nitrogen and CO2
1390-UCCryogenic version, brass piston

Where is Jefferson equipment used?

  • Combustion installations: solenoid valves for fuel gas, diesel and heavy fuel oil
  • Steam and hot water installations: solenoid valves for heating and recirculation
  • Industrial gas technology: cryogenic solenoid valves for oxygen, argon, nitrogen and CO2
  • Water treatment and irrigation: solenoid valves for water, with slow-closing versions

How do we supply Jefferson in Romania?

We can quote Jefferson solenoid valves from the general-purpose, combustion, 3-way and 4-way and special-service series. For an accurate quotation, send the series or order code, the fluid, the differential pressure, the temperature, the connection diameter, the thread type and the coil voltage. For spare parts, add the type of seal and piston. We supply to order, usually in 1–4 weeks; depending on the series and the specification the lead time may be longer, and the exact date is stated in the quotation.

The compatibility of a replacement item with an existing solenoid valve is checked in the quotation, by series, order code and a photo of the nameplate.

Frequently asked questions about Jefferson

What are the 1314, 1330, 1342CL and UC series at Jefferson?

Jefferson makes solenoid valves, divided into four lines: general purpose, combustion, 3-way and 4-way, and special services. The series are identified by numbers such as 1314, 1327, 1330 or 1342, and suffixes mark versions, for example UC for cryogenic fluids.

How do I choose between series 1314 and 1330?

Series 1314 is for general purpose, with a bronze or stainless steel body, for water, air and steam. Series 1330 and 2030 are for fuel gas and other gases, with a cast aluminium body. Send the fluid, the pressure and the temperature, and we check the suitable series.

Do you supply Jefferson solenoid valves in Romania, and how fast?

Yes. The solenoid valves are ordered and usually arrive in 1–4 weeks. A series can ship in 24–72 h when the item is in stock, locally or at the supplier. Depending on the series and the specification, the lead time may increase; the exact date is stated in the quotation.

Can I replace an old solenoid valve with a Jefferson version?

This can be checked from the series on the nameplate, the fluid, differential pressure, connection and coil voltage. We check equivalence between series against the data: send the data and a photo of the existing solenoid valve, and we check whether a suitable version exists in the range.

How do I specify the request for a 1327-UC or 1314-UC solenoid valve?

The 1314-UC version is cryogenic, and 1327-UC is the cryogenic version for oxygen. For a UC version, send the base series, for example 1327 or 1314, the cryogenic fluid, the temperature, the differential pressure, the connection diameter and the coil voltage. For liquid CO2, state whether the temperature drops below −60 °C. With these details we check the suitable version.

How do I request a Jefferson quotation?

Send the Jefferson code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Jefferson Solenoid Valves (manufacturer documentation)