Krohne supplier in Romania
For Krohne we quote OPTIFLUX and WATERFLUX electromagnetic flowmeters, OPTIMASS Coriolis flowmeters, OPTISONIC ultrasonic flowmeters and OPTISWIRL vortex flowmeters; we start from the code on the nameplate.
Founded in 1921 · Headquarters: Duisburg, Germany
Who is Krohne and what does it make?
Krohne is a German manufacturer specialised in industrial flowmeters, with an international presence. For over 100 years it has developed and produced electromagnetic, Coriolis, ultrasonic, vortex and variable area flowmeters for the accurate measurement of liquids, gases and steam in process applications. Krohne combines a century of expertise with constant innovation.
The Krohne portfolio covers a wide range of flow rates, temperatures and pressures.
Krohne equips critical measuring systems in the chemical, oil and food industries, where flow accuracy directly affects process costs.
What do we supply from the Krohne range?
| Product | Description |
|---|---|
| OPTIFLUX series electromagnetic flowmeters | Electromagnetic flowmeters measure the flow of conductive liquids (>5 µS/cm) with no pressure loss and no moving parts. Faraday principle: the conductive liquid passes through the magnetic field and generates a voltage proportional to its velocity. Accuracy of ±0.2% of the measured value on OPTIFLUX 4300. Sizes from DN2.5 to DN3000, operating temperature up to +180°C; nominal pressure depends on the model (for example PN40 / ASME Cl. 300 on OPTIFLUX 5100). Electrodes in Hastelloy C, tantalum, platinum or titanium for any aggressive fluid. PTFE, PFA, hard rubber or polyurethane liner. Compact or remote versions with a 30 m cable. Output 4-20mA, pulse, HART, PROFIBUS, Modbus, Foundation Fieldbus. |
| OPTIMASS series Coriolis mass flowmeters | Coriolis technology measures mass (kg/h, t/h) and liquid density directly, without temperature or pressure compensation. The vibrating measuring tube is deformed by the Coriolis force when the fluid flows, and the measured phase shift is proportional to the mass. Accuracy depends on the model (for example ±0.05% for OPTIMASS 6400, ±0.1% for OPTIMASS 7400). Measures viscous liquids, pastes, slurries and gases; the temperature range reaches -200...+400°C on OPTIMASS 6400. Sizes from DN10 to DN400, depending on the model; OPTIMASS 6400: DN10-300, pressure up to PN160 / ASME 1500. Sanitary versions with tri-clamp connection for food/pharma. Output 4-20mA, HART, PROFIBUS, EtherNet/IP, integrated batch controller. |
| OPTISONIC series ultrasonic flowmeters | Ultrasonic flowmeters use the transit time of ultrasonic signals through the liquid to calculate the average velocity. Zero pressure loss, installation on an existing pipe (clamp-on) or in-line with flanges. Accuracy 0.5% or 1% of the measured value, bi-directional. Sizes DN15 to DN4000, temperature -40°C to +200°C. Applications: drinking water, wastewater, hydrocarbons, acids, bases. ATEX/IECEx zone 1 explosion-proof versions. Advanced diagnostics detect entrained gas, turbulence and uneven velocity profile. Power supply 85-260VAC or 20-55VDC. |
| OPTISWIRL series vortex flowmeters | The vortex principle: a bluff body placed in the flow generates Kármán vortices with a frequency proportional to the velocity. Piezoelectric sensors detect the frequency and calculate the flow. Measures liquids, gases and saturated/superheated steam. The permitted temperature depends on the model (OPTISWIRL 4200: up to +240°C; OPTISWIRL 5080: up to +427°C and PN160 / ASME 1500 at the flange). Sizes DN15-DN300. No moving parts, zero maintenance. Integrated temperature and pressure compensation for gases and steam - measures mass in kg/h or Nm³/h directly. Output 4-20mA, pulse, HART, PROFIBUS. Versions with functional safety and for explosion-risk areas, according to the manufacturer's documentation. |
Why Krohne?
- Accuracy depends on the technology and the model (for example ±0.2% for OPTIFLUX 4300, ±0.05% for OPTIMASS 6400)
- Calibration and certificates
- No moving parts in the flow on electromagnetic flowmeters - no mechanical wear and no pressure loss
- Direct mass measurement (Coriolis) - kg/h, t/h without calculating density
- Bi-directional - measures flow in both directions without reconfiguration
- Advanced diagnostics - detection of cavitation, entrained gas, empty pipes, electrode coating
Which Krohne codes and series are requested most often?
| Code | Description |
|---|---|
| OPTIFLUX 1050 | compact electromagnetic flowmeter for general applications |
| OPTIFLUX 2100 | electromagnetic flowmeter for water and wastewater |
| OPTIFLUX 4300 | precision electromagnetic flowmeter for industry |
| OPTIFLUX 4400 | electromagnetic flowmeter for safety instrumented systems (SIS) and advanced process applications |
| OPTIFLUX 5100 | electromagnetic flowmeter with ceramic measuring tube, for aggressive and abrasive media |
| WATERFLUX 3070 | electromagnetic flowmeter for water distribution networks |
| WATERFLUX 3100 | electromagnetic flowmeter for measuring water consumption |
| POWERFLUX 4300 | electromagnetic flowmeter for nuclear industry applications |
| POWERFLUX 5300 | electromagnetic flowmeter for nuclear industry applications |
| ENVIROMAG | electromagnetic flowmeter for the water and wastewater industry |
| TIDALFLUX 2300 | electromagnetic flowmeter for partially filled pipes |
| AF-E 400 | electromagnetic flowmeter for utilities and industrial automation |
Where is Krohne equipment used?
- Oil & Gas - custody transfer measurement, production allocation, fiscal metering
- Chemical & Petrochemical - batch reactors, continuous distillation, blending
- Water & Wastewater - drinking water billing, wastewater plant control
- Food & Beverage - ingredient dosing, CIP, pasteurisation, fermentation
- Pharmaceutical - sterile reactors, WFI, API dosing
- Power Generation - measurement of fuel, feedwater and steam
- Pulp & Paper - white/black liquor, coating, waste water
- Mining & Metals - sulphuric acid, mineral slurries, leaching
- HVAC - thermal energy, cooling, district heating
- Marine & Offshore - fuel consumption, ballast, cargo
How do we supply Krohne in Romania?
We source Krohne flowmeters to order, and availability for each measuring technology is checked on each request. Technical parameters are taken from the manufacturer's technical documentation, and the actual delivery time is confirmed after checking with the supplier. As a general rule, common electromagnetic or vortex flowmeters can arrive in 24–72 h when the item is in stock, locally or at the supplier, while specially configured Coriolis or ultrasonic instruments go through the order flow, usually 1–4 weeks. Send us the measured fluid, the pipe diameter and the flow range for a quick check of suitable options. DAkkS-accredited calibrations are outside our offer, and commissioning for custody transfer applications requires the manufacturer's direct involvement.
Commissioning for custody transfer applications requires the manufacturer's direct involvement, and DAkkS-accredited calibrations are outside our offer.
Frequently asked questions about Krohne
What is the difference between the Krohne OPTIFLUX and WATERFLUX flowmeters?
OPTIFLUX is the family of electromagnetic flowmeters, with versions for basic applications, water and wastewater, advanced processes or aggressive and abrasive media, depending on the model. WATERFLUX is dedicated specifically to drinking water and distribution networks, often with buried installation and low power consumption. The right choice depends on the type of application and the installation conditions in the field.
What is the difference between the Krohne OPTIFLUX 1050 and ENVIROMAG flowmeters?
OPTIFLUX 1050 is an electromagnetic flowmeter for basic applications with conductive liquids, while ENVIROMAG is an electromagnetic flowmeter for the water and wastewater industry. The choice depends on the application: a general industrial process or a water network. We confirm the exact version from the code on the nameplate and the nominal size.
What details should I send for a Krohne flowmeter quotation?
Specify the nominal pipe diameter, the minimum and maximum flow, the fluid type and its conductivity, the operating pressure and temperature, and the electrical output type required. If you are replacing an existing flowmeter, the code on the nameplate and the flange diameter help identify the equivalent version in the current range quickly.
When is the TIDALFLUX flowmeter used instead of a Krohne OPTIFLUX?
TIDALFLUX 2300 is designed for pipes that are not always completely full, such as gravity sewers, where an ordinary electromagnetic flowmeter would not measure the partial level correctly. OPTIFLUX requires the pipe to be permanently full of liquid for a correct reading. The choice depends on how full the pipe actually is at the installation point.
How do I request a Krohne quotation?
Send the Krohne code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Krohne, KROHNE Messtechnik GmbH (manufacturer documentation)