Leiden Cryogenics supplier in Romania

For Leiden Cryogenics we quote CF-CS110, CF-CS-XXL and Quper dilution refrigerators, RF and DC wiring and cold insertable probes, based on the cooling power at 100 mK, the minimum temperature and the number of cable lines.

Founded in 1992 · Headquarters: Leiden, the Netherlands

Request a quote

Who is Leiden Cryogenics and what does it make?

Leiden Cryogenics is a Dutch manufacturer of cryogen-free dilution refrigerators, based in Leiden, active since 1992. These systems bring the temperature down to millikelvin without liquid helium, using pulse tubes and a helium-3 dilution circuit, and serve research at extremely low temperatures and the testing of quantum devices.

The CF-CS110 family has a 490 mm mixing chamber plate, 160 l of sample space, three 120 mm side ports and a 110 mm central port for the cold insertable probe. There are three versions: CF-CS110-500 with more than 500 µW at 100 mK and a minimum temperature below 10 mK, CF-CS110-1000 with more than 1000 µW and below 9 mK, and CF-CS110-1500 with more than 1500 µW and below 8 mK, with two pulse tubes. The CF-CS-XXL model has a 1 m plate, weighs over 2.5 tonnes, delivers over 3000 µW at 120 mK, has a minimum temperature of 5 mK and four pulse tubes. Quper is an inverted dilution refrigerator, with tabletop access, a minimum temperature below 25 mK, more than 300 µW at 100 mK and a full warm-cold-warm cycle under 24 hours, with no liquid nitrogen. All can be equipped with RF wiring up to 18 GHz (extendable to 40 GHz), DC wiring, a motorised lift table, a cold insertable probe and superconducting magnets up to 14 T.

For a researcher or a laboratory manager, what matters is the cooling power at 100 mK, the minimum temperature, the number of cable lines and the plate size. Identifying a spare part starts from the system type and its serial number.

What do we supply from the Leiden Cryogenics range?

ProductDescription
CF-CS110-500, -1000 and -1500A cryogen-free dilution refrigerator, with a 490 mm mixing chamber plate, 160 l of sample space, a minimum temperature between 10 and 8 mK and 500, 1000 or 1500 µW of power at 100 mK, with one or two pulse tubes.
CF-CS-XXLA large system, with a 1000 mm mixing chamber plate, over 2.5 tonnes, 12 ports of 120 mm, a minimum temperature of 5 mK, over 3000 µW at 120 mK, four pulse tubes and a liquid nitrogen pre-cooling circuit (listed in the model specifications).
QuperAn inverted dilution refrigerator, with tabletop access, a minimum temperature below 25 mK, over 300 µW at 100 mK, less than 10 l of helium-3, up to 36 semi-rigid RF lines and over 100 high-density RF lines; full cycle under 24 hours.
Wiring, insertable probe and magnetsRF wiring with SMA, SMP or K connectors up to 18 GHz, DC wiring with Thermocoax or high voltage, a cold insertable probe for samples, a motorised lift table and compatibility with superconducting magnets up to 14 T.

Why Leiden Cryogenics?

  • Tiered cooling power at 100 mK — CF-CS110 in three versions of 500, 1000 and 1500 µW, plus CF-CS-XXL with 3000 µW at 120 mK
  • No liquid nitrogen on the Quper — a full warm-cold-warm cycle under 24 hours, with a 200 mm mixing chamber plate and tabletop access
  • Room for quantum wiring — more than 300 SMA lines or 1000 high-density RF lines on the CF-CS110 and more than 600 SMA or 2000 RF on the CF-CS-XXL
  • Fast sample exchange — a cold insertable probe, inserted from the top, from room temperature to base temperature in 6 hours
  • Handling by a single person — the vacuum can and the shields are lifted with the motorised table in less than 20 minutes

Which Leiden Cryogenics codes and series are requested most often?

CodeDescription
CF-CS110-500Dilution refrigerator, over 500 µW at 100 mK, below 10 mK, one pulse tube
CF-CS110-1000Dilution refrigerator, over 1000 µW at 100 mK, below 9 mK
CF-CS110-1500Dilution refrigerator, over 1500 µW at 100 mK, below 8 mK
CF-CS-XXLDilution refrigerator, over 3000 µW at 120 mK, 5 mK
QuperInverted dilution refrigerator, below 25 mK, cycle under 24 hours
Cold insertable probeSample exchange from room temperature to base temperature in 6 hours
Lift tableLifting of the vacuum can and shields by a single person
Cablaj RFSMA, SMP or K lines up to 18 GHz, extendable to 40 GHz
Cablaj DCTwisted and shielded lines, Thermocoax, flexible coaxial or high voltage
Nitrogen pre-cooling circuitCooling from room temperature to base temperature in less than 24 hours

Where is Leiden Cryogenics equipment used?

  • Quantum computing — testing qubits in CF-CS110, CF-CS-XXL and Quper refrigerators
  • Condensed matter physics — measurements at millikelvin temperatures
  • Research with superconducting magnets — systems compatible with magnets up to 14 T
  • Scanning probe microscopy — low vibration level, with mounting in the insertable probe
  • University research — extremely low temperature laboratories

How do we supply Leiden Cryogenics in Romania?

We quote Leiden Cryogenics systems and parts: CF-CS110, CF-CS-XXL and Quper dilution refrigerators, RF and DC wiring, cold insertable probes and accessories, supplied to order. The lead time for series parts is usually 1–4 weeks, while complete refrigerators are configured per project and have a much longer lead time. For a quotation we need the type of the existing system and its serial number, or the requirements of the new system: the cooling power at 100 mK, the minimum temperature, the number and type of cable lines, the magnet wanted, the sample size.

The performance of a new system depends on the cooling power required at 100 mK, on the thermal load of the wiring and on the installation conditions in the laboratory.

Frequently asked questions about Leiden Cryogenics

What does Leiden Cryogenics make?

Leiden Cryogenics makes cryogen-free dilution refrigerators for millikelvin temperatures in Leiden, the Netherlands: the CF-CS110 and CF-CS-XXL series and the Quper model, with RF and DC wiring, cold insertable probes and compatibility with superconducting magnets. The company has worked in this field since 1992.

How do I choose between CF-CS110-500, -1000 and -1500?

They differ in cooling power at 100 mK, of over 500, 1000 or 1500 µW, in minimum temperature (below 10, 9 or 8 mK) and in the number of pulse tubes. The choice depends on the thermal load of the wiring and of the sample. Send us the number of RF and DC lines and the temperature requirements.

Can you bring Leiden Cryogenics systems to Romania, and how fast?

We supply the systems to order, and the lead time for series parts is usually 1–4 weeks. Complete refrigerators, with wiring and magnet, are configured per project and have a much longer lead time, stated in the quotation once we establish the laboratory's requirements.

Can I replace or add to the wiring of an existing refrigerator?

This is checked from the system type, the plates available, the connector type (SMA, SMP, K), the frequency band (18 or 40 GHz) and the thermal load allowed. Compatibility is confirmed on the basis of these data; send us the type of refrigerator and the current list of lines.

What data do I send for a quotation on a dilution refrigerator?

Send the cooling power required at 100 mK, the minimum temperature, the number and type of RF and DC lines, whether you need a cold insertable probe, a superconducting magnet (up to 14 T) or wiring for cryo-CMOS, the sample size and the installation space in the laboratory.

How do I request a Leiden Cryogenics quotation?

Send the Leiden Cryogenics code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.