Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

SHI Cryogenics supplier in Romania

Gifford-McMahon and pulse tube cryocoolers, cryopumps and helium compressors

Request a quote

Who is SHI Cryogenics and what does it make?

SHI Cryogenics is a Japanese maker of cryogenic systems. Production is at Tanashi in Japan, Allentown in Pennsylvania and Batangas in the Philippines. It also has subsidiaries in Europe. The products are used in medical systems, semiconductors, telecommunications, electronics, biochemical processes, vacuum deposition and laboratory equipment.

The range falls into three families. Gifford-McMahon cryocoolers come in two-stage versions (from the RDC-02K, with 0.02 W at 2.3 K, up to the RDK-415D2, with 1.5 W at 4.2 K, plus 10 K class models such as the CH-210) and single-stage versions for 20 K, 40 K and 77 K. Pulse tube cryocoolers, the RP series, are offered for 4 K. Cryopumps include the SICERA Smart KZ and Ultra KV series and the Marathon CP, in sizes of 8–20 in (200–500 mm), which can be serviced “hot” without breaking the vacuum. Helium compressors F-70, FA-70, F-40 or CNA-11 drive the cryocoolers and cryopumps.

The equipment is used in physics and materials laboratories and in vacuum installations for coatings and semiconductors. A typical request concerns replacing a cryocooler or a compressor, based on the nameplate model and the number of operating hours.

What do we supply from the SHI Cryogenics range?

ProductDescription
Two-stage Gifford-McMahon cryocoolersModels from the RDC-02K (0.02 W at 2.3 K) to the RDK-415D2 (1.5 W at 4.2 K), the RDE-418D4 (1.8/2.0 W at 4.2 K) and the CH-210, from the 10 K class. They cover laboratory and industrial cryogenic applications, from 2.3 K upwards.
Single-stage and pulse tube cryocoolersSingle-stage models for 20 K, 40 K and 77 K (RDK-500B2, RDK-400B, RD-125D, CH-104), plus the RJT-100 GM-JT for 4 K, and the pulse tube series RP-062B, RP-082B2 and RP-222B3S.
SICERA and Marathon CP cryopumpsSICERA Smart KZ (KZ-08 to KZ-20) and Ultra KV (KV-08 to KV-12) with cold traps, and Marathon CP-8, CP-8LP and CP-250LP for high-vacuum processes, with standard flanges and manual or automatic functions.
Helium compressorsThe F-70 and FA-70 families (water-cooled and air-cooled respectively), F-40, FA-40, FA-50, CNA-11 and EC-77N, in single-phase and three-phase versions, which drive the cryocoolers and cryopumps.

Why SHI Cryogenics?

  • Cryocoolers from 2.3 K to 77 K — the RDC-02K reaches 0.02 W at 2.3 K, and the single-stage models cover 20 K, 40 K and 77 K
  • Two cooling technologies — Gifford-McMahon, with one or two stages, and pulse tube, both available for 4 K
  • High-vacuum cryopumps — SICERA and Marathon CP, with “hot” servicing (hot swap) without interrupting the vacuum on the Marathon CP series
  • Helium compressors for different power supplies — water-cooled or air-cooled versions, single-phase and three-phase, for 240 V and below, and 380 V and above respectively
  • Production in three countries — plants in Japan, the USA and the Philippines, plus subsidiaries in Europe

Which SHI Cryogenics codes and series are requested most often?

CodeDescription
RDC-02KTwo-stage GM cryocooler, 0.02 W at 2.3 K
RDK-101DTwo-stage GM cryocooler, 4 K
RDK-408D2Two-stage GM cryocooler, 1.0 W at 4.2 K
RDK-415D2Two-stage GM cryocooler, 1.5 W at 4.2 K
RDE-418D4Two-stage GM cryocooler, 4 K
CH-210Two-stage GM cryocooler, 10 K
RDK-500B2Single-stage GM cryocooler, 20 K
RD-125DSingle-stage GM cryocooler, 77 K
RP-082B2Pulse tube cryocooler, 4 K
SICERA Smart KZ-08Cryopump from the Smart KZ series
SICERA Ultra KV-10Cryopump and cold trap from the Ultra KV series
Marathon CP-8Cryopump for high-vacuum processes
F-70Water-cooled helium compressor
FA-70Air-cooled helium compressor

Where is SHI Cryogenics equipment used?

  • Semiconductors — cryopumps for PVD, ion implantation and other high-vacuum processes
  • Research and laboratories — specialised laboratory equipment
  • Medical systems — equipment that uses cryogenic cooling
  • Vacuum coatings — cryopumps and cold traps for deposition chambers
  • Telecommunications and electronics — equipment that uses cryogenic cooling

How do we supply SHI Cryogenics in Romania?

From the SHI Cryogenics range we can quote cryocoolers, cryopumps, helium compressors and spare parts, based on the exact model. Items are supplied to order, usually in 1–4 weeks; for complete systems or special configurations the lead time may be longer, confirmed in the quotation. For a correct request, please send the nameplate model of the cryocooler or cryopump, the compressor model, the electrical supply (single-phase or three-phase, voltage), the cooling type (water or air), the number of operating hours and, for an existing system, the application and the target temperature.

Compatibility between a given cryocooler and compressor is confirmed from the data on the nameplates.

Frequently asked questions about SHI Cryogenics

What does SHI Cryogenics make?

SHI Cryogenics makes Gifford-McMahon and pulse tube cryocoolers, SICERA and Marathon CP cryopumps, helium compressors and accessories. The equipment serves semiconductors, research laboratories, medical systems and vacuum deposition.

How do I choose a cryocooler by temperature and cooling capacity?

Start from the target temperature and the thermal load. The RDC-02K offers 0.02 W at 2.3 K, the RDK-415D2 offers 1.5 W at 4.2 K, and the single-stage models work at 20 K, 40 K or 77 K. Tell us the temperature, the load in watts and whether vibration matters.

Do you supply SHI Cryogenics equipment in Romania, and how fast?

Yes, to order. Lead time is usually 1–4 weeks; complete systems may need longer. Items can ship in 24–72 h when the item is in stock, locally or at the supplier. The exact lead time is confirmed in the quotation.

Can I replace an existing SHI cryocooler or compressor?

Compatibility is confirmed after checking. We need the model from the cryocooler and compressor nameplates, the electrical supply, the cooling type and the number of operating hours. Compressors are available in single-phase and three-phase versions, for voltages up to 240 V or from 380 V upwards.

What information do you need for a cryopump quotation?

We need the model or size (for example 8, 10, 12, 16 or 20 in), the flange type, the series (SICERA Smart, Ultra or Marathon CP), the associated compressor, the process the cryopump works in (PVD, ion implantation, etc.) and the electrical supply. A photo of the nameplate helps with identification.

How do I request a SHI Cryogenics quotation?

Send the SHI Cryogenics code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Sumitomo Heavy Industries, Ltd. (manufacturer documentation)