Who is Cryofab and what does it make?

Cryofab is an American maker of cryogenic vessels and accessories, founded in 1971 and based at Kenilworth, New Jersey. It makes and repairs storage vessels, dewars, transfer lines and hoses, valves and bayonet couplings for helium, nitrogen, argon, oxygen, hydrogen and liquefied natural gas. The vessels have capacities from 1 litre to 5,000 litres, and the products are offered in versions with approvals as per the manufacturer’s documentation.

The range is divided by type of liquid. For liquid helium, the line includes CMSH portable dewars with vapour shielding and superinsulation, CSM/CVSM dewars for superconducting magnets, CFHT transfer hoses and C3000 valves. For nitrogen, oxygen and argon there are CL/CLPB tanks, CF open flasks, CFCL flexible lines and CH horizontal vessels. For liquid hydrogen, the CLH series starts at 100–400 litres. The Cryocomp line brings together vacuum-jacketed valves, vent components, bayonet assemblies and heaters.

For Romania, the range is useful to laboratories that supply superconducting magnets or NMR/MRI systems, to producers that handle liquid nitrogen or helium and to installations that need vacuum-insulated lines made to specification. A clear request starts from the liquid, the volume, the working pressure, the standards required (PED, ASME, DOT) and the diameter of the connections.

What do we supply from the Cryofab range?

ProductDescription
CMSHPortable dewars for storage, transport and distribution of liquid helium, with minimal losses thanks to vapour shielding technology and superinsulation; they have a roller base and interchangeable fitting bundles.
CLHPortable vessels for storage, transport and distribution of liquid hydrogen, in standard sizes of 100–400 litres, with a safety system and vacuum-insulated fill and drain connections.
CFOpen dewar flasks for nitrogen, oxygen or argon, with diameters of 4–96 inches and depths of up to 20 feet, made of double-wall stainless steel with multilayer insulation.
Transfer lines and hosesFlexible stainless steel hoses, with or without vacuum insulation (CFHT, CFCL, CFUL), for the transfer of liquid helium, nitrogen, argon and oxygen in the laboratory and in industry.

Why Cryofab?

  • Vessels from 1 to 5,000 litres — from laboratory dewars to industrial storage vessels
  • CMSH dewars for liquid helium — multilayer vapour shielding and superinsulation, without liquid nitrogen shielding and without circulation of helium gas
  • Approvals as per the manufacturer’s documentation — the CMSH dewars are also available in versions relevant for transport and use in the EU
  • The Cryocomp line of valves and bayonets — vacuum-jacketed valves for all cryogens, from ¼ to 2 inches
  • Made to order — the ability to produce vacuum-insulated lines to the customer’s specification, from ¼ to 2 inches outside diameter of the inner pipe

Which Cryofab codes and series are requested most often?

CodeDescription
CMSHPortable dewars for liquid helium
CSMDewars for superconducting magnets
CVSMDewars for superconducting magnets
CFHTTransfer hose/line for liquid helium
C3000Valves for liquid helium, ½ and 1 inch
C5000Vacuum-jacketed valves, ¼ to ½ inch
CB700Cryogenic bayonets for vacuum-insulated lines
CL / CLPBPortable tanks for liquid nitrogen
CFOpen dewar flasks for nitrogen, oxygen, argon
CFCLFlexible vacuum-insulated hose for liquid nitrogen
CFULFlexible non-insulated stainless steel line
CFNLow-pressure vessel for atmospheric storage
CHHorizontal cryogenic storage vessels
CLD / CHDVehicle-mounted cryogenic transport vessels
C2000Cryogenic valves from ¼ to 2 inches
CLHPortable vessels for liquid hydrogen

Where is Cryofab equipment used?

  • Medical imaging and MRI — liquid helium supply for superconducting magnets
  • Research laboratories — storage and transfer of liquid nitrogen and helium
  • Industrial gases — vessels, transport vessels and lines for distribution
  • Hydrogen energy — portable vessels for liquid hydrogen
  • OEM producers — cryogenic vessels made to order, in short or long runs

How do we supply Cryofab in Romania?

We can quote Cryofab dewars, transfer hoses, valves and couplings based on the liquid handled, the volume and the standards required by your installation. Send the series or code from the nameplate of the existing vessel (for example CMSH, CF or C3000) or the diameters and pressure for a new line. We supply to order, usually in 1–4 weeks; for vessels made to specification the lead time may be longer and we state it in the quotation. Spare parts for vessels are identified by series.

Local approvals of a vessel for a specific application are checked against the exact model and its documents.

Frequently asked questions about Cryofab

What product range does Cryofab have?

Cryofab makes and repairs cryogenic vessels: dewars, storage tanks, transfer lines and hoses, valves and bayonet couplings, for helium, nitrogen, argon, oxygen, hydrogen and liquefied natural gas. Capacities range from 1 litre to 5,000 litres.

How do I choose a dewar for liquid helium?

The choice depends on the capacity, the type of use (storage, transport, distribution or magnet refilling) and the standards required, for example TPED or PED for the EU. On the CMSH, the low losses come from the multilayer vapour shielding. Specify the volume and the place of use.

Can you supply Cryofab products in Romania, and in what lead time?

Yes, to order. For catalogue vessels and accessories the lead time is usually 1–4 weeks; for special manufacture, such as vacuum-insulated lines to specification, it may be longer. We give the exact lead time in the quotation.

Can I replace a valve or a transfer hose with a Cryofab model?

It depends on the liquid, the connection diameter, the bayonet type and the pressure. Equivalence is confirmed after checking; send photos, the dimensions and the series of the existing part, and we check the suitable version.

What information do you need for a quotation for a cryogenic vessel?

State the liquid, the volume needed, the working pressure, the standard required (PED, ASME, DOT), the type of connections and whether the vessel is moved often. For a spare part, add the serial number of the vessel.

How do I request a Cryofab quotation?

Send the Cryofab code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote