Gardner Cryogenics supplier in Romania
Containers and tanks for liquid helium and hydrogen
Who is Gardner Cryogenics and what does it make?
Gardner Cryogenics designs and manufactures tanks and containers for storing and transporting liquid hydrogen and helium, with over six decades of experience. The company has produced ISO containers for almost 60 years and has delivered over 2,200 tanks and containers since 1973, and one of the containers delivered at the start is still in service. Production capacity includes over 190,000 square feet of manufacturing and service workshops.
For helium, the transport range goes from 3,785 to 56,781 litres, and stationary storage from 12,870 to 128,000 litres, with larger or smaller variants on request. A typical product is the 41,640-litre UN portable tank in a 40-foot ISO frame. For hydrogen, the company builds semi-trailers and tanks in 300 series stainless steel on the inside and high-strength carbon steel on the outside; it presents a 64,352-litre hydrogen semi-trailer and UN tanks that can work with either helium or hydrogen. The containers comply with codes such as ASME, DOT, UN Portable, CSC, IMDG, ADR and European standards.
In Romania, these products may interest industrial gas operators, laboratories with high consumption of liquid helium and units that already have Gardner containers and look for parts, vacuum transfer lines or repairs. A request starts with the container type, the capacity, the required codes and the tank serial number.
What do we supply from the Gardner Cryogenics range?
| Product | Description |
|---|---|
| UN containers for liquid helium | 41,640 L UN portable tanks in a 40 ft ISO frame, for road and sea transport of liquid helium. |
| Helium transport and storage tanks | Transport tanks of 3,785–56,781 L and stationary storage of 12,870–128,000 L, with special variants on request. |
| Hydrogen semi-trailers and tanks | Semi-trailers, tanks and storage containers for liquid hydrogen, in 300 series stainless steel on the inside, including a 64,352 L semi-trailer. |
| Transfer lines and components | Transfer lines with or without vacuum insulation, containers and spare parts for helium and hydrogen installations. |
Why Gardner Cryogenics?
- 41,640 L UN container in a 40 ft ISO frame — the format commonly used for containerised transport of liquid helium
- Wide helium capacities — transport of 3,785–56,781 L and stationary storage of 12,870–128,000 L
- Tanks for helium or hydrogen — UN containers can work with either helium or hydrogen
- Complies with international codes — ASME, DOT, UN Portable, CSC, IMDG, ADR and European standards
- Repair and recertification — dedicated workshops for refurbishment, retesting and repair, supported by an in-house team
Which Gardner Cryogenics codes and series are requested most often?
| Code | Description |
|---|---|
| UN Portable 41.640 L | Container for liquid helium in a 40 ft ISO frame |
| Helium transport 3,785 L | Lower limit of helium transport tanks |
| Helium transport 56,781 L | Upper limit of helium transport tanks |
| Helium storage 12,870 L | Lower limit of stationary helium tanks |
| Helium storage 128,000 L | Upper limit of stationary helium tanks |
| Hydrogen semi-trailer 64,352 L | Semi-trailer for liquid hydrogen transport |
| UN Portable helium/hydrogen | UN tank that can work with helium or hydrogen |
| Vacuum transfer line | Transfer line with vacuum insulation |
| Non-vacuum transfer line | Transfer line without vacuum insulation |
| Spare parts | Components for containers and transfer lines |
Where is Gardner Cryogenics equipment used?
- Industrial gases — transport and distribution of liquid helium and hydrogen
- Large research laboratories — stationary storage of liquid helium
- Sea and road transport — UN containers in ISO frames and semi-trailers
- Hydrogen — storage and transport of liquid hydrogen
- Container fleet maintenance — repair, retesting and recertification
How do we supply Gardner Cryogenics in Romania?
We can take requests for Gardner Cryogenics parts, transfer lines and tanks if you send us the container type and series, the capacity, the fluid (helium or hydrogen) and the codes required for transport. For new containers, production is to order and the lead time depends on volume and configuration; we confirm it and state it in the quotation. For parts and transfer lines the lead time to order applies, usually 1–4 weeks. Tanks are supplied to order.
The transport approvals (ADR, IMDG) of a container for a given route are checked from the container documents.
Frequently asked questions about Gardner Cryogenics
What products does Gardner Cryogenics make?
Gardner Cryogenics makes tanks, ISO containers and semi-trailers for storing and transporting liquid helium and hydrogen, plus transfer lines and parts. The company has produced over 2,200 tanks and containers since 1973.
How do I choose a container for liquid helium?
The choice depends on the volume transported, the route (road or sea) and the applicable codes. The 41,640 L UN container in a 40 ft ISO frame is a usual format; for smaller volumes there are tanks from 3,785 L upwards. Send the quantity and the route.
How long does delivery to Romania take for Gardner Cryogenics products?
They are supplied to order. Parts and transfer lines usually take 1–4 weeks; for new containers the lead time is much longer, depends on the factory and is confirmed in the quotation.
Can I replace a part of an existing Gardner container?
Yes, usually the part is identified by the container series and the part number. Compatibilities between different series are confirmed after checking; send the series, photos of the part and, if available, the drawing, and we check the compatibility.
What data are needed for a quotation on a cryogenic tank?
State the fluid (helium or hydrogen), the capacity, the type (storage, road transport or containerised), the required codes and the series of an existing tank, if it is a replacement or a repair.
How do I request a Gardner Cryogenics quotation?
Send the Gardner Cryogenics code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Gardner Cryogenics (manufacturer documentation)