ICEoxford supplier in Romania
For ICEoxford we quote DRY ICE dry cryostats (3 K, 1 K, dilution) and WET ICE wet cryostats (77 K, 1.5 K, dilution), with or without a magnet; for a quotation we need the base temperature, the sample space and the optical access.
Founded in 2004 · Headquarters: Witney, United Kingdom
Who is ICEoxford and what does it make?
ICEoxford is a British maker of cryostats for research at very low temperatures, based in Witney, near Oxford, and active since 2004. The systems are designed and built in two families. DRY ICE dry cryostats cool the sample without liquid nitrogen or helium: a cryocooler liquefies helium at about 4 K, and pumping the helium allows the temperature to drop below 1 K. WET ICE wet cryostats use a reservoir of liquid cryogen, nitrogen or helium, around the sample.
The DRY ICE series starts with base systems of 3 K, 8 K or 10 K, in versions with optical access, compatible with ultra-high vacuum or with a magnetic field. Next come the 1 K systems, including a benchtop version and one with a cooling power of 320 mW at 1 K, and the Eden (10 mK) and Mini-Eden (50 mK) dilution cryostats, with automatic cool-down. On the wet side there are liquid nitrogen cryostats at 77 K, the 1.5 K WET ICE models with a sample space of 42, 70 or 100 mm, and the D ICE DIPPER, EASIFIT and UHV dilution cryostats.
The range matters in materials physics, spectroscopy, measurements in a magnetic field, quantum optics and ion traps, where the sample must be cooled reproducibly and with low vibration. The choice starts from the base temperature, the diameter of the sample space, optical or electrical access (wiring), the desired magnetic field and the laboratory's ability to provide liquid cryogen or only electrical power and compressed air.
What do we supply from the ICEoxford range?
| Product | Description |
|---|---|
| DRY ICE 3K and 10K | Cryostats without liquid cryogen, with a base temperature of 3 K, 8 K or 10 K: 3K ION for ion traps, compatible with ultra-high vacuum, 3K OPTI MAGNETO with optical access and a benchtop design, 3K FLEXI, upgradeable to 1 K, 3K INV with an inverted structure and DRY ICE 4K for Mössbauer spectroscopy. |
| DRY ICE 1K | The 1 K family includes DRY ICE 1.0K, the compact 1K Benchtop version, 1K High Cooling Power (320 mW at 1 K), 1K ARPES with side loading for angle-resolved photoemission spectroscopy and ICE-Q 1K for molecular spin qubits. The wiring is customised. |
| Eden and Mini-Eden dilution cryostats | Eden DRY ICE reaches 10 mK, with a flexible sample space and customisable wiring; Mini-Eden reaches 50 mK, and is compact and light. Both cool down automatically. The ICE CP 20 mK cold probe completes the offer for measurements on an insert. |
| WET ICE wet cryostats | Systems with liquid cryogen: WET ICE 77K OPTI with nitrogen and optical access, a calibration cryostat for LNG, 1.5 K models with MAGNETO magnet (70 or 100 mm), OPTI (42 mm), for radiation beams and with VTI, plus D ICE DIPPER, EASIFIT and UHV dilution cryostats. |
Why ICEoxford?
- DRY ICE systems without liquid nitrogen or helium — cooling with a cryocooler, without the logistics of liquid cryogens in the laboratory
- Base temperatures from 77 K down to 10 mK — the programme includes liquid nitrogen, 3 K, 1 K and dilution cryostats
- Cooling power of 320 mW at 1 K on the DRY ICE 1K High Cooling Power model — large sample space and dense wiring
- Optical access on many models (3K OPTI MAGNETO, 1K, WET ICE 1.5K OPTI) — suitable for spectroscopy and quantum optics
- MAGNETO versions with a sample space of 70 or 100 mm — cryostats with a magnet for measurements in a magnetic field
Which ICEoxford codes and series are requested most often?
| Code | Description |
|---|---|
| DRY ICE 3K ION | Cryostat without liquid cryogen, 3 K, compatible with ultra-high vacuum, for ion traps |
| DRY ICE 3K OPTI MAGNETO | Benchtop cryostat with optical access and magnet |
| DRY ICE 3K FLEXI | 3 K cryostat, upgradeable to 1 K |
| DRY ICE 3K INV | 3 K cryostat with an inverted structure |
| DRY ICE 4K | 4 K cryostat for Mössbauer spectroscopy |
| DRY ICE ACTIVE SORB | Dry cryostat with active sorption |
| DRY ICE 1.0K | 1 K cryostat with optical access and magnetic field |
| DRY ICE 1K Benchtop | Compact benchtop cryostat, 1 K |
| DRY ICE 1K High Cooling Power | 1 K cryostat with 320 mW at 1 K |
| DRY ICE 1K ARPES | 1 K cryostat with side loading for ARPES |
| DRY ICE 10mK Eden | Dilution cryostat, 10 mK |
| DRY ICE 50mK Mini-Eden | Compact dilution cryostat, 50 mK |
| ICE CP 20mK | 20 mK cold probe |
| WET ICE 77K OPTI | Liquid nitrogen cryostat with optical access |
| WET ICE 1.5K 70mm MAGNETO | 1.5 K wet cryostat with magnet, 70 mm sample space |
| D ICE EASIFIT | Wet dilution cryostat, 250 mm sample space |
Where is ICEoxford equipment used?
- Materials physics — measurements at low temperature and in a magnetic field
- Quantum technologies — dilution cryostats for qubits and quantum optics
- Spectroscopy — Mössbauer, ARPES and measurements with optical access
- Ion traps — systems compatible with ultra-high vacuum
- Cryogenic calibration — cryostats for liquid nitrogen and LNG
How do we supply ICEoxford in Romania?
From the ICEoxford programme we can quote DRY ICE and WET ICE cryostats, dilution inserts, cold probes and accessories for existing systems. For a correct quotation, send the desired base temperature, the diameter of the sample space, the optical or electrical access (windows, number of wires), the magnetic field and the laboratory's utility data. For a system that is already installed, the model name and the serial number help us. ICEoxford systems are supplied to order, usually in 1–4 weeks. Depending on the specification, the lead time may be longer, especially for custom configurations. The exact lead time appears in the quotation.
The custom cryostat configuration (windows, wiring, magnet) is set on the basis of the full specification of the experiment.
Frequently asked questions about ICEoxford
What does ICEoxford make?
ICEoxford builds cryostats for very low temperatures at Witney: DRY ICE systems without liquid cryogen, from 10 K down to 10 mK with dilution, and WET ICE systems with liquid nitrogen or helium, with or without a magnet. They are used in physics, spectroscopy and quantum technology laboratories.
How do I choose between a dry and a wet cryostat?
The dry system does not use liquid nitrogen or helium, but it needs electrical power and the cryocooler's utilities, and in a power cut it has no hold time like a liquid reservoir. The wet cryostat keeps the sample cold as long as there is cryogen in the reservoir. Tell us the temperature and the duration of the experiment.
Can you supply ICEoxford cryostats in Romania, and in what lead time?
Yes. Systems are supplied to order: usually 1–4 weeks. Depending on the specification, the lead time may be longer, especially for custom configurations. For small parts: 24–72 h when the item is in stock, locally or at the supplier. We confirm the exact lead time in the quotation.
I have an older ICE cryostat; what data do you need for a part or an upgrade?
The model name from the system nameplate (for example DRY ICE 1.0K), the serial number, a photo of the part concerned and, for upgrades, the desired temperature or magnetic field. With these we request confirmation of the part for your system.
What do I need to specify for a dilution cryostat quotation?
The base temperature required (10 mK for Eden, 50 mK for Mini-Eden), the size of the sample space, the number of wires and filters required, the optical access, the magnetic field and whether the laboratory has power for the cryocooler and pumps. On this basis we determine the model.
How do I request a ICEoxford quotation?
Send the ICEoxford code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: ICEoxford (manufacturer documentation)

