Who is Cryogenic Limited and what does it make?

Cryogenic Limited is a British manufacturer of high-field superconducting magnets and low-temperature measurement systems that work without liquid helium. It makes its magnets in its own workshops in London, and the company is extending its production space: doubling the area of the main building, an in-house electronics area, a controlled-environment room and increased winding capacity. The reason is simple to understand: liquid helium is an expensive consumable, and in countries without their own sources it limits laboratory work.

The offer is divided into several lines. The cryogen-free measurement system (CFMS) combines a superconducting magnet with a dry cryostat and allows VSM measurements, AC susceptibility, resistivity, Hall effect, heat capacity, thermal conductivity and the Seebeck effect. The S700X SQUID magnetometer is an instrument for DC and AC measurements of magnetic properties as a function of field and temperature. Other categories: custom research systems with fields of over 20 T, magnets for NMR, MRI and ESR, ultra-low temperature systems and quantum Hall resistance standards.

In Romania, this equipment is of interest to physics institutes, magnetic materials laboratories and groups who want to avoid dependence on helium deliveries. The request is defined by the magnetic field required, the temperature range, the type of measurement and the sample space.

What do we supply from the Cryogenic Limited range?

ProductDescription
CFMSCryogen-free measurement system, with a high-field superconducting magnet and measurement options for VSM, resistivity, Hall effect, heat capacity and thermal conductivity.
S700X SQUIDSQUID magnetometer for DC and AC measurements of magnetic properties, with its own magnet, a mu-metal shield and a re-condensing version (S700X-R) with a 1 W cooler for zero helium loss.
Custom research systemsHigh-field superconducting magnets up to 20 T (NbSn), and over 25 T with HTS insert coils, and systems built to requirement, including configurations with optical access or for X-ray scattering.
NMR, MRI and ESR systemsHigh-resolution magnets and systems for NMR, MRI and ESR, with gradient coils, RF probes and consoles.

Why Cryogenic Limited?

  • Operation without liquid helium — magnet and measurement systems that remove the consumption and logistics of liquid helium
  • In-house magnets — coils of copper-stabilised filamentary conductor, vacuum-impregnated with epoxy resin
  • S700X SQUID magnetometer — input sensitivity of the order of 10⁻³⁰ J/√Hz, with a mu-metal shield for low residual field
  • High fields — research systems with superconducting magnets up to 20 T (NbSn) and over 25 T with HTS insert coils
  • A range of measurements on the same platform — VSM, AC susceptibility, Hall effect, heat capacity and thermal conductivity

Which Cryogenic Limited codes and series are requested most often?

CodeDescription
CFMSCryogen-free measurement system
S700XSQUID magnetometer
S700X-RS700X version with re-condensing cryostat and 1 W cooler
VSMMeasurement option with vibrating sample magnetometer
AC susceptibilityAC susceptibility measurement option
Hall effectHall effect measurement option
Heat capacityHeat capacity measurement option
Thermal conductivityThermal conductivity measurement option
ULT systemCryogen-free system at ultra-low temperatures
NMR / MRI / EPR magnetHigh-resolution magnet for NMR, MRI and ESR
QHR standardQuantum Hall resistance standard system
Custom research magnetCustom superconducting magnet, up to 20 T (NbSn) or over 25 T with HTS insert

Where is Cryogenic Limited equipment used?

  • Magnetic materials physics — VSM and SQUID characterisation as a function of field and temperature
  • Superconductivity research — transport and Hall measurements at low temperatures
  • NMR and ESR spectroscopy — high-resolution magnets and systems
  • Electrical metrology — systems with a quantum Hall resistance standard
  • Scientific facilities — dedicated magnets for X-rays, microscopy and particle physics

How do we supply Cryogenic Limited in Romania?

For Cryogenic Limited equipment we receive technical requests and check them before the quotation. For a quotation, it helps to have the magnetic field wanted in tesla, the temperature range, the type of measurement (VSM, Hall, susceptibility), the sample size and any optical access requirements. The systems are built to order, and the lead time is usually much longer than 1–4 weeks, depending on the configuration. The lead time is stated in the quotation.

The systems are built per project, so the final configuration and the lead time are given from the detailed specification of the project.

Frequently asked questions about Cryogenic Limited

What does Cryogenic Limited make?

The British company builds high-field superconducting magnets and low-temperature measurement systems that work without liquid helium: CFMS systems, the S700X SQUID magnetometer, magnets for NMR and ESR and systems with a quantum Hall standard.

How do I choose between a CFMS system and a SQUID magnetometer?

CFMS is a measurement platform with several options (VSM, Hall, heat capacity, etc.), while S700X is a SQUID magnetometer for DC and AC magnetic properties. The choice depends on sensitivity, the field required and the temperature range of the sample.

Can you supply Cryogenic Limited systems in Romania, and within what lead time?

Yes, to order. As the systems are built per project, the lead time may be longer, depending on the specification; we confirm it in the quotation, once the manufacturer sets the configuration.

Can I adapt an existing system with a new magnet?

It depends on the existing cryostat and compressor, the inner diameter required and the field wanted. Compatibility is confirmed after checking; send the description of the system and the requirements of the experiment, and we pass them to the manufacturer.

What information do you need for a quotation on a superconducting magnet?

State the field in tesla, the homogeneity required, the diameter and geometry of the working space, the sample temperature, the type of access (optical, X-ray) and whether the system must be cryogen-free. For measurements, also specify their type.

How do I request a Cryogenic Limited quotation?

Send the Cryogenic Limited code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote