Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Lighthouse Instruments supplier in Romania

FMS laser headspace analysers, CCI Tester and PULSAR

Headquarters: Charlottesville, Virginia, USA

Request a quote

Who is Lighthouse Instruments and what does it make?

Lighthouse Instruments is an American company based in Charlottesville, Virginia, which makes optical, non-destructive systems for analysing the free space above the product (headspace) in sterile pharmaceutical containers. It introduced its first laser analysis platforms in 2000. Lighthouse systems check container integrity without opening or destroying the containers.

FMS-Oxygen measures oxygen in sealed containers by laser absorption and detects leaks, in glass or plastic, clear or amber. FMS-Carbon Dioxide uses carbon dioxide as a tracer gas for container closure integrity testing (CCIT) and for the inspection of media fill containers. FMS-Moisture/Pressure measures moisture and total pressure simultaneously in lyophilised vials and confirms that the vacuum is maintained. The CCI Tester conditions the samples in a vessel pressurised to 20 psig (1.38 barg) and detects defects from 0.1 microns up to large defects. PULSAR is the automated 100% inspection system for oxygen and pressure in the headspace, with rejection of non-conforming containers, and FMS-Water Activity completes the range.

For a quotation, the type of product, the container and the headspace parameter followed matter.

What do we supply from the Lighthouse Instruments range?

ProductDescription
FMS-OxygenHeadspace oxygen analyser for sealed containers, based on patented laser absorption, for quality control, process validation and closure integrity testing, on glass or plastic.
FMS-Carbon Dioxide and CCI TesterCO2 headspace analysis for CCIT and the inspection of media fill containers; the CCI Tester adds automatic conditioning of the samples in a pressurised vessel, in a deterministic and non-destructive system.
FMS-Moisture/Pressure and FMS-Water ActivityInstruments for lyophilised products: they measure moisture and total pressure directly through the container, confirming that the vacuum is maintained, and water activity.
PULSAR and IlluminatorPULSAR is the automated headspace inspection system at filling line speed, with automatic sorting; the Illuminator and the FMS automation module complete the automation range.

Why Lighthouse Instruments?

  • Non-destructive measurement through the container wall — without opening the vial and without losing product
  • CCI Tester with carbon dioxide as a tracer gas — detects defects from 0.1 microns up to large defects, deterministically
  • PULSAR for 100% inspection — oxygen and pressure in every container, with automatic rejection on the filling line
  • FMS-Moisture/Pressure for lyophilised products — moisture and total pressure measured simultaneously
  • Continuously verified calibration — PULSAR uses four permanently mounted reference vials, for checking the sensors during operation

Which Lighthouse Instruments codes and series are requested most often?

CodeDescription
FMS-OxygenHeadspace oxygen analyser
FMS-Carbon DioxideHeadspace CO2 analyser for CCIT
FMS-Moisture/PressureHeadspace moisture and pressure analyser
FMS-Water ActivityWater activity analyser
CCI TesterDeterministic container closure integrity testing system
PULSARAutomated headspace inspection system
IlluminatorInstrument from the Lighthouse automation range
FMS Automation ModuleAutomation module for FMS analysers

Where is Lighthouse Instruments equipment used?

  • Sterile parenteral products — control of oxygen and integrity
  • Lyophilised products — vacuum retention and residual moisture
  • Pharmaceutical plants — automated inspection of filled containers
  • Validation and quality — stability studies and batch release
  • Testing laboratories — headspace analysis on sealed samples, without opening the container

How do we supply Lighthouse Instruments in Romania?

We can quote Lighthouse analysers, standards, accessories and parts for existing instruments, supplied to order. Parts and consumables arrive to order, usually within 1–4 weeks; new analysers are equipment configured for the container and the product, with a longer lead time, confirmed in the quotation. For a correct quotation, send us the type of container (vial, syringe, ampoule), the material and volume, the parameter followed (oxygen, CO2, moisture, pressure), the working rate and, for parts, the model and series of the instrument.

The qualification of a method on a given container is established from the calibration curves made on that container.

Frequently asked questions about Lighthouse Instruments

What products does Lighthouse Instruments make?

Lighthouse Instruments, from Charlottesville, makes non-destructive laser headspace analysers for sterile pharmaceutical containers: FMS-Oxygen, FMS-Carbon Dioxide, FMS-Moisture/Pressure, FMS-Water Activity, the CCI Tester and the PULSAR automated system, plus laboratory services.

How do I choose between FMS-Oxygen, the CCI Tester and PULSAR?

FMS-Oxygen does spot laboratory analyses, the CCI Tester tests integrity with CO2 as a tracer in a pressurised vessel, and PULSAR automatically inspects every container on the line. The volume of containers and the stage of the product matter. Send us the type of container and the rate.

Can you supply Lighthouse analysers in Romania, and within what lead time?

Yes, supply is to order. Parts and consumables come to order, usually within 1–4 weeks, and new analysers, configured for the container, have a longer lead time, set in the quotation.

Can PULSAR replace dye testing?

The methods differ: PULSAR measures the oxygen and pressure in the headspace, while the dye test checks leakage probabilistically. Replacement is assessed case by case. Tell us the product and the regulatory requirement, and the assessment is confirmed after checking.

What data should I send for a quotation for a Lighthouse analyser?

The type, material and volume of the container, the product (liquid, lyophilised), the headspace parameter followed, the number of samples or the line rate and, for parts, the model and series of the instrument.

How do I request a Lighthouse Instruments quotation?

Send the Lighthouse Instruments code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Lighthouse Instruments LLC (manufacturer documentation)