M&C TechGroup supplier in Romania
Sample conditioning for analysers: probes, coolers, filters, pumps
Founded in 1985 · Headquarters: Ratingen, Germany
Who is M&C TechGroup and what does it make?
M&C TechGroup is a German company based in Ratingen, founded in 1985, that makes everything between the process gas sampling point and the analyser: sampling probes, filters, gas coolers, pumps, lines, sample monitoring systems and analysers. Some of the special systems are designed and manufactured in Ratingen and Aach, with an in-house engineering department.
The reason a gas analyser works or not in a real installation is usually sample conditioning. If dust, water or corrosive compounds reach the analyser, the measurement is spoiled. Heated probes prevent dust from sticking to water vapour, universal filters and aerosol filters stop fine particles, and coolers lower the dew point of the sample: on most models the outlet dew point is adjustable between 2 and 15 °C, while deep coolers reach -20…-30 °C. The Peltier ECP4X/ECP5X series expands modularly from 1 to 4 independent cooling modules, at ambient temperatures of up to +50 °C.
As analysers, the company makes modular GenTwo multigas units for a 19 inch rack or an IP54 wall enclosure, and the ILA1-X000-EX in-situ laser for oxygen or SO2, with a single process flange. For Romania, the range is of interest to suppliers of emission analysis systems, refineries, power plants and steelworks, as well as to the maintenance of existing sampling systems. In a quotation, the gas, the temperature and pressure, the dust load, the target dew point and the area classification matter.
What do we supply from the M&C TechGroup range?
| Product | Description |
|---|---|
| SP180-H (heated sampling probes) | Electrically heated probe for continuous extraction of gas from dust-laden processes. There is the SP180-H EX T2/T3/T4 version for zone 1 and SP180H-MA for marine applications. |
| Gas coolers (ECP4X/ECP5X, ECP2000C) | Modular Peltier coolers that lower the dew point of the sample before the analyser, with condensate alarm and potential-free relays, used in extractive emission and process systems. |
| PSS5C | Portable sample conditioning system, in a case with trolley and strap, revised for EN 15267-4:2017 (IP42, monitored gas temperature), intended for mobile measurements. |
| GenTwo and ILA1-X000-EX | Modular multigas analysers for rack or wall, with variable sensors, and an in-situ laser analyser for oxygen or sulphur dioxide in explosive atmospheres. |
Why M&C TechGroup?
- The sample path from a single company — from the SP180-H heated probe, through filters and coolers, to pumps, lines and the analyser
- SP180-H probe with a version for Ex zone 1, according to the manufacturer's documentation, with low volume and short response time
- Modular Peltier coolers ECP4X/ECP5X — from 1 to 4 channels, with independent modules and alarms for liquid sensors
- PSS5C portable conditioning system — adapted to the requirements of EN 15267-4:2017, useful for temporary emission measurements
- ILA1-X000-EX laser analyser — measures O2 or SO2 in-situ without sampling and sample conditioning
Which M&C TechGroup codes and series are requested most often?
| Code | Description |
|---|---|
| SP180-H | Electrically heated sampling probe |
| SP180-H EX T2/T3/T4 | Heated probe for Ex zone 1, according to the manufacturer's documentation |
| SP180H-MA | Heated probe for marine applications |
| ECP4X | Modular Peltier gas cooler, 1–4 channels |
| ECP5X | Modular Peltier gas cooler |
| ECP2000C | Peltier gas cooler |
| PSS5C | Portable conditioning system according to EN 15267-4:2017 |
| PSS5 | Portable sample conditioning system |
| PSP4000 | Sampling probe, compatible with the PSS5C portable system |
| GenTwo V2.4 | Modular multigas analyser, 19 inch rack or IP54 enclosure |
| ILA1-X000-EX | In-situ laser analyser for O2 or SO2, Ex zone |
Where is M&C TechGroup equipment used?
- Power plants and incineration — extractive emission monitoring systems
- Refineries and petrochemicals — sample conditioning and process analysis
- Steel and cement — gases laden with dust and moisture
- Inerting and controlled combustion — oxygen monitoring in pipes
- Maritime transport — systems for exhaust gas analysis
How do we supply M&C TechGroup in Romania?
We can quote M&C components and systems for the gas sample path, from probes, filters and coolers to pumps and analysers. Supplied to order, usually in 1–4 weeks for standard items; panels and special systems designed for the application may have a longer lead time, confirmed in the quotation. To identify the right part, the code from the nameplate of the existing device helps or, for a new system, the gas, the temperature and pressure, the dust and moisture concentration, the desired dew point and the Ex zone class. We also ask for the type of analyser that follows the conditioning.
The probe or filter is chosen from the process gas data, and the design of a complete conditioning system is confirmed only after the application has been analysed.
Frequently asked questions about M&C TechGroup
What product range does M&C TechGroup have?
The German company from Ratingen makes gas analysis equipment: heated sampling probes, filters, gas coolers, analysis pumps, lines, sample monitoring systems and multigas or laser analysers. It also supplies conditioning panels designed for the application.
How do I choose a gas cooler for an analyser?
The choice starts from the dew point required at the analyser inlet and from the flow and humidity of the sample. Standard coolers reach an adjustable dew point between 2 and 15 °C, and deep coolers -20…-30 °C. The ambient temperature also matters, up to +50 °C on the ECP4X/ECP5X series.
Do you supply M&C equipment in Romania and within what lead time?
Yes, components are supplied to order. Standard parts usually take 1–4 weeks; special conditioning panels, systems in heated enclosures or those for Ex zones may have longer lead times. The exact lead time appears in the quotation, after the gas and the certification requirements have been clarified.
Can I replace an older M&C probe or cooler?
Compatibility is confirmed once the exact model is known. Send the type (for example SP180-H or ECP), the series, the supply voltage, the length and the process connection, plus photos of the nameplate. We check the current successor or the wear parts needed.
What data should I send for a quotation on a sample conditioning system?
The gas composition and the corrosive components, the temperature and pressure in the pipe, the dust load, the humidity, the flow required by the analyser, the target dew point, the Ex zone class and the type of analyser. For mobile emission measurements, also state whether the system has to comply with EN 15267-4.
How do I request a M&C TechGroup quotation?
Send the M&C TechGroup code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: M&C TechGroup (manufacturer documentation)