For Messkonzept we quote FTC 320, FTC 320 EX, FTC 150 thermal conductivity gas analysers and the FTC 150-OEM and FTC 320-OEM OEM versions; we need the gas pair, the measuring range and the Ex zone requirement.
Founded in 2000 · Headquarters: Frankfurt am Main, Germany
Who is Messkonzept and what does it make?
Messkonzept, from Frankfurt am Main, Germany, has developed and manufactured gas detectors and analysers based on the thermal conductivity principle since 2000. The company has an in-house application laboratory, in which it reproduces customers' measuring tasks before the instrument is chosen.
The thermal conductivity detector (TCD) measures gases such as H2, He, N2, Ar, Ne, Kr and Xe, in binary or quasi-binary mixtures. The analyser range includes FTC 320, the new generation of analysers with improved electronics, FTC 320 EX, approved for zone 2 under ATEX directive 2014/34/EU, and the compact FTC 150 transmitter, in an IP65 housing, with a stainless steel gas path, resistant to pressures of up to 20 bar and with up to 16 stored mixture linearisations. The OEM versions, FTC 150-OEM and FTC 320-OEM, are detectors without housing, for the customer's own designs.
The instruments are found in gas analysis of combustion processes, in measuring helium in air, in flammable gases and in handling sample gas under vacuum. The limit of the principle matters when choosing: thermal conductivity works well when the two components of the mixture have very different conductivities, which is why the gas pair decides whether the analyser can be used. The company also offers consulting, adjustment and adaptation of existing hardware. For a quotation, send the gas pair, the measuring range and the process conditions.
What do we supply from the Messkonzept range?
| Product | Description |
|---|---|
| FTC 320 analyser | The new generation of thermal conductivity analysers, with improved electronics compared with FTC 300 and reduced noise in the trace range. Options include corrosion protection, measurement of combustible gases, compensation of cross-sensitivity and protection against condensate and dust. |
| FTC 320 EX analyser | FTC 320 with zone 2 approval under ATEX directive 2014/34/EU; the functions and measuring characteristics are those of FTC 320. The housings are tested for protection type nR. |
| FTC 150 transmitter | Small transmitter for extractive measurements, in an IP65 housing, without a local display. The stainless steel gas path withstands up to 20 bar, and the instrument stores up to 16 gas mixture linearisations. |
| FTC 150-OEM and FTC 320-OEM OEM detectors | Thermal conductivity detectors without housing, for customers who integrate them into their own instrument. They are intended for areas without explosion hazard. |
Why Messkonzept?
- Thermal conductivity principle — suited to binary or quasi-binary mixtures, for example H2 in air or He in Ar
- FTC 320 EX approved for ATEX zone 2 — used in areas with a potentially explosive atmosphere
- FTC 150 in an IP65 housing with a stainless steel gas path, resistant up to 20 bar — compact transmitter for extractive measurements, without a local display
- OEM versions without housing — the detector is integrated into the customer's own instrument
- In-house application laboratory — the measuring task is reproduced before the version is chosen
Which Messkonzept codes and series are requested most often?
| Code | Description |
|---|---|
| FTC 320 | Thermal conductivity gas analyser, new generation |
| FTC 320 EX | Version approved for ATEX zone 2 |
| FTC 150 | Compact IP65 transmitter for quasi-binary mixtures |
| FTC 150-OEM | OEM detector without housing |
| FTC 320-OEM | OEM detector without housing |
| FTC 300 | Previous series of thermal conductivity analysers |
| FTC 400 | Analyser from earlier generations, with infrared photometry combined with thermal conductivity |
| TCD | Thermal conductivity detector |
Where is Messkonzept equipment used?
- Combustion processes — analysis of combustion gas mixtures
- Measuring helium in air — detection with FTC analysers
- Flammable gases — versions with measurement of combustible gases
- Vacuum installations — measuring sample gas under vacuum
- Instrument building — OEM detectors integrated into the customer's equipment
How do we supply Messkonzept in Romania?
We can quote Messkonzept analysers from the FTC 320 and FTC 150 series, the FTC 320 EX version and OEM detectors. For a correct quotation we need the gas pair or the mixture to be measured, the concentration range, the process pressure and temperature, the presence of condensate or dust and any Ex zone requirement. If you are replacing an existing instrument, send the nameplate and the output configuration. The analysers are supplied to order, usually in 1–4 weeks; for special configurations or Ex versions the lead time may be longer. The exact lead time is stated in the quotation.
The measuring ranges and the options for each gas mixture are set in the quotation, after we receive the gas composition, the process pressure and the temperature.
Frequently asked questions about Messkonzept
What distinguishes FTC 320, FTC 320 EX and FTC 150 from Messkonzept?
FTC 320 is a thermal conductivity gas analyser, FTC 320 EX is the version approved for ATEX zone 2, and FTC 150 is a compact IP65 transmitter for quasi-binary mixtures. There are also OEM versions, without housing.
How do I choose between FTC 320 and FTC 150?
FTC 320 is the new generation of analysers, with options such as measurement of combustible gases, cross-sensitivity compensation and protection against condensate. FTC 150 is a compact IP65 transmitter, without a local display, for quasi-binary mixtures. Send the gases and the process conditions, and we confirm the version in the quotation.
Do you supply Messkonzept analysers in Romania and how fast?
The analysers are supplied to order in Romania, usually in 1–4 weeks, and can ship in 24–72 h when the item is in stock, locally or at the supplier. For special configurations or Ex versions the lead time may be longer; the exact lead time is confirmed in the quotation.
Can I measure any gas mixture with an FTC analyser?
The FTC analyser measures binary or quasi-binary mixtures, in which the gases have different thermal conductivities. This is why the choice depends on the gas pair, the concentration range and any accompanying gases. Send the composition of the sample gas, and we assess whether the measurement is possible.
What data do I send for an FTC 320 or FTC 150 analyser?
Send the gas to be measured and the carrier gas, the concentration range, the process pressure and temperature, the presence of condensate or dust and the Ex zone requirement. If you are replacing an existing analyser, add the type, for example FTC 300 or FTC 320, and the output configuration.
How do I request a Messkonzept quotation?
Send the Messkonzept code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.