McCrometer supplier in Romania
V-Cone, electromagnetic and propeller flow meters
Headquarters: Hemet, California, USA
Who is McCrometer and what does it make?
McCrometer is an American flow meter manufacturer based in Hemet, California. The company builds differential pressure flow meters (V-Cone and Wafer-Cone), electromagnetic flow meters, propeller flow meters for water and open channel instruments, with registers, transmitters and telemetry devices. The company has over 70 years of activity (since 1955).
The distinctive part is the V-Cone, a conical element mounted on the axis of the pipe, patented by the company in 1985 and installed in over 75,000 units. The cone conditions the flow profile by itself, so it needs little or no straight run upstream and downstream, and the declared accuracy is up to ±0.5% of reading. The Wafer-Cone uses the same principle for small diameters, in a flangeless design, with a reduced straight run.
On the electromagnetic side, the Ultra Mag 5000 is a wafer-type model for water, wastewater, sludge and conductive liquids, with an UltraLiner liner, for which hygiene approvals are stated in the manufacturer's documentation; it can operate with one diameter upstream and zero downstream, with accuracy of up to ±0.5%, or ±0.2% in the high-accuracy option. For Romania, the range is of interest to treatment plants, water networks and process installations where there is no space for long straight runs. The order is based on pressure, temperature, flow rate, the properties of the fluid and the inside diameter of the pipe.
What do we supply from the McCrometer range?
| Product | Description |
|---|---|
| V-Cone | Differential pressure flow meter for liquids, steam and gases, with a central cone, accuracy of up to ±0.5% of reading and custom variants in special materials, such as Hastelloy. |
| Wafer-Cone | Flangeless version for small pipes, with a reduced straight run and accuracy of up to ±1% (compared with ±0.5% for the V-Cone); replaceable element, no moving parts. |
| Ultra Mag 3000 and 5000 | Wafer-type electromagnetic flow meters for conductive liquids and sludge, associated with transmitters from the ProComm family; the 5000 version has a high-accuracy option of ±0.2%. |
| McPropeller | Propeller flow meters for measuring water with impurities or large flows in irrigation, industry and municipal networks, with a mechanical register and a six-digit totaliser. |
Why McCrometer?
- V-Cone element with its own flow conditioning — requires a reduced straight run, useful in retrofits in narrow spaces
- Over 75,000 V-Cones installed — in oil, gas, industry and water applications
- Flangeless Wafer-Cone — the version for small diameters, with a replaceable element when flow conditions change
- Ultra Mag 5000 with UltraLiner (hygiene approvals according to the manufacturer's documentation) — for drinking water, wastewater and sludge with no obstruction in the pipe
- In-house calibration laboratory, with accreditation stated in the manufacturer's documentation
Which McCrometer codes and series are requested most often?
| Code | Description |
|---|---|
| V-Cone | Differential pressure flow meter, central cone |
| Wafer-Cone | Flangeless V-Cone for small pipes |
| Ultra Mag 3000 | Wafer electromagnetic flow meter with 3000 series transmitter |
| Ultra Mag 5000 | Wafer electromagnetic flow meter, ±0.2% option |
| Field Mag 3000 | Electromagnetic flow meter for pipes with Victaulic connection |
| Field Mag 5000 | Electromagnetic flow meter for pipes with Victaulic connection, 5000 series |
| Vera Mag 5000 | Electromagnetic flow meter for high temperatures |
| FPI Mag 3000 | Insertion electromagnetic flow meter |
| SPI Mag 5000 | Insertion electromagnetic flow meter, SPI system |
| McPropeller | Propeller flow meter for water |
| FS100 | Flow straightener |
| FL900 | Flow recorder for open channels |
| FLO-DAR | Radar and ultrasonic flow sensor for channels |
| ProComm Max | Transmitter for electromagnetic flow meters |
Where is McCrometer equipment used?
- Water and wastewater treatment — measurement at plants, mains and channels
- Oil and gas — onshore and offshore pipelines, where there is no space for straight runs
- Energy — steam and process water in power plants
- Food and pharmaceutical — small pipes with the Wafer-Cone
- Irrigation — water with particles, measured with a propeller
How do we supply McCrometer in Romania?
From the McCrometer offer we can prepare quotations for V-Cone and Wafer-Cone flow meters, Ultra Mag and Field Mag electromagnetic models, McPropeller propellers, transmitters and accessories. The equipment is supplied to order, usually in 1–4 weeks; for V-Cone elements configured to a specification, the lead time may be longer. It helps to have: the fluid, the minimum and maximum flow rate, the pressure, the temperature, the inside diameter of the pipe, the flange class and, for replacements, the series from the nameplate of the existing instrument.
The compatibility of a V-Cone element with a transmitter or flow computer of another make is checked for each configuration.
Frequently asked questions about McCrometer
What does McCrometer make?
McCrometer makes V-Cone and Wafer-Cone differential pressure flow meters, Ultra Mag, Field Mag and Vera Mag electromagnetic flow meters, McPropeller propellers, open channel instruments and transmitters.
When should you choose a V-Cone instead of an orifice plate?
The V-Cone has its own flow conditioning and needs little straight run, so it is chosen for retrofits with little space, for dirty fluids or with a disturbed profile. We need the fluid, the pressure, the temperature, the flow rate and the inside diameter of the pipe.
Within what lead time do you supply McCrometer flow meters in Romania?
We can supply McCrometer equipment in Romania, to order. To order, usually 1–4 weeks; V-Cone elements made to a specification may need a longer lead time, which we communicate in the quotation.
Can I replace an old McCrometer flow meter with a current model?
It depends on the diameter, the flange class, the model of the transmitter and the outputs used. Equivalences are confirmed after checking. Send a photograph of the nameplate and the series, and we check the right current version.
What data do you need for a quotation on a V-Cone?
The process properties (pressure, temperature, minimum and maximum flow rate, density or viscosity) and the pipe data: inside diameter, schedule and flange class. Also state the material wanted, for example stainless steel or Hastelloy.
How do I request a McCrometer quotation?
Send the McCrometer code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: McCrometer (manufacturer documentation)

