Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Lindab supplier in Romania

For Lindab we quote circular ducts and fittings from the Safe system, control and shut-off dampers (DRU, DSU, DTU), constant or variable flow units (DAU, FTCU) and WH25 circular fire dampers; we need the diameter, the damper type and the actuation.

Request a quote

Who is Lindab and what does it make?

Lindab makes ventilation systems for buildings and industrial installations: circular ducts and fittings, control and shut-off dampers, flow measuring and control units and fire dampers.

The Safe system is a circular duct system with a double EPDM gasket, factory-fitted, Eurovent-certified in airtightness class D. The dimensions follow EN 1506, and the Click function exists, in principle, on all Safe products in diameters Ø80–315. They are made of galvanised steel, 304 or 316L stainless steel, aluminium and other materials. The dampers are grouped into control (DRU, DIRU), shut-off (DSU, DTU, DTMU, DTBU), constant or variable flow units (DAU, DAVU, FTCU, VRU) and flow measuring units (FRU, FMU).

The dampers are supplied with manual, electric or pneumatic actuation, and the WH25 circular fire dampers have a 25 mm closing blade and diameters from 100 to 315 mm; they are tested to EN 1366-2 and classified to EN 13501-3. When choosing, what matters is the diameter, the function, the material, the airtightness class and the type of actuation. Dampers with a Safe or Safe Click connection are part of the same Eurovent-certified system.

What do we supply from the Lindab range?

ProductDescription
Safe circular ducts and fittingsDucts, bends, tees, reducers, end caps and couplings, with a double EPDM gasket and dimensions to EN 1506. They are made of galvanised steel, stainless steel, aluminium and other materials; the Click function exists on diameters Ø80–315.
Control and shut-off dampers (DRU, DIRU, DSU, DTU)Circular dampers for balancing the installation or for shut-off. Control dampers do not close tightly, while shut-off dampers have rubber gaskets on the blade. They can come with an electric or pneumatic motor.
Flow units (DAU, DAVU, FTCU, VRU, FRU)Automatic units for constant or variable flow and flow measuring units, with electric actuation. They are chosen according to the diameter, the flow range and the control signal.
WH25 circular fire dampersDampers for ducts that pass through fire-rated walls or floors, with a 25 mm closing blade, in diameters from Ø100 to Ø315. The versions have manual or motorised control.

Why Lindab?

  • Safe system with a double EPDM gasket: sealant-free installation, with Eurovent-certified class D airtightness
  • Click function on most Safe products in Ø80–315: the duct is fixed into the fitting by clicking, during installation
  • Control, shut-off and flow dampers in the same connection system: they fit directly on Safe ducts
  • Manual, electric or pneumatic actuation: the version is chosen according to the control method in the installation
  • Special materials (304 and 316L stainless steel): for environments with high hygiene or corrosion requirements

Which Lindab codes and series are requested most often?

CodeDescription
SafeCircular duct system with a double EPDM gasket, airtightness class D
DRUCircular control damper
DIRUCircular control damper
DSUCircular shut-off damper
DTUCircular shut-off damper, high airtightness
DAUAutomatic constant flow unit
DAVUAutomatic variable flow unit
FTCUActuated flow control unit
VRUFlow control unit
FRUFlow measuring unit
WH25Circular fire damper, 25 mm blade

Where is Lindab equipment used?

  • Industrial ventilation: airtight circular ducts and control dampers
  • Hospitals and clean rooms: Safe system in stainless steel or with a special coating
  • Food and beverage industry: stainless steel ducts and dampers
  • Marine installations: dampers and ducts for shipboard ventilation
  • Buildings with fire compartmentation: circular fire dampers

How do we supply Lindab in Romania?

We can quote Lindab ventilation components: Safe ducts and fittings, control and shut-off dampers, flow units and circular fire dampers. For a correct quotation, send the code or type of damper (for example DRU, DTU, DAU, WH25), the nominal diameter, the material, the airtightness class required and the type of actuation. For a fitting, specify the shape and the angle. Ventilation items are supplied to order. To order, the lead time is usually 1–4 weeks, and an item can ship in 24–72 h when the item is in stock, locally or at the supplier; depending on the specification, the lead time may be longer. The exact lead time is confirmed in the quotation.

For fire dampers we check the type, diameter and actuation in the quotation, and installation remains as per the instructions in the technical documentation of the model.

Frequently asked questions about Lindab

What Lindab ventilation components are there, from Safe ducts and fittings to circular fire dampers?

Safe circular ducts and fittings, control and shut-off dampers, constant or variable flow units, flow measuring units and circular fire dampers. The Safe system has a double EPDM gasket and Eurovent-certified airtightness class D.

How do I choose a control or shut-off damper?

Control dampers (DRU, DIRU) serve to balance the flow and do not close tightly. Shut-off dampers (DSU, DTU and versions) have higher airtightness classes. Send the diameter, the function required and whether you need an electric or pneumatic motor.

Do you supply Lindab in Romania and how quickly?

Lindab items are brought in to order. To order, the lead time is usually 1–4 weeks, and an item can ship in 24–72 h when the item is in stock, locally or at the supplier. Dampers with a motor or with special materials may take longer, depending on the specification.

Can I replace an old damper with a current model?

We check the replacement on the basis of the code on the damper, the diameter and the type of actuation. For motorised ones, we need the voltage and the type of motor. A photo of the nameplate or the damper helps us identify the current model.

What should I send for a quotation on a WH25 fire damper?

The nominal diameter between Ø100 and Ø315, the type of control (manual or magnet-operated, with motor), whether position microswitches are present and the supply voltage of the magnet or motor. Also specify the type of wall or floor penetrated.

How do I request a Lindab quotation?

Send the Lindab code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote