Raychem supplier in Romania
Electric tracing: BTV, QTVR, VPL cables, Elexant controllers
Who is Raychem and what does it make?
Raychem is a brand of electrical heat tracing systems, with more than 50 years of activity in thermal and electrical sensing solutions. The brand may still be found on older products and documentation under a previous name. The systems maintain or raise the temperature of pipes, tanks and equipment: freeze protection, process temperature maintenance, tank heating, heating of long pipelines, plus leak detection. A complete system has cable, connection kits, thermostats or controllers and design tools.
Cables are chosen by technology. Self-regulating ones adapt their output to the pipe temperature, power-limiting ones are suited to high output and high exposure temperatures, and mineral-insulated ones to high outputs, high exposure temperatures or very corrosive environments. The industrial families include BTV, QTVR, XTV(R), HTV and VPL. QTVR, for example, holds a process temperature of up to 110 °C and can be installed at −60 °C. On very long pipelines, integrated systems have circuits of up to 50 km, and skin effect heating (STS) works up to 260 °C and at voltages of up to 10 kV.
Controllers, from the Elexant 3500i thermostat to the Elexant 4020i controller, add monitoring and DCS integration. Electric tracing is used on water and product lines that freeze in winter, on tanks with viscous fluids and on process lines in the chemical and oil and gas industries. Sizing is done on length, insulation, maintained temperature and Ex zone, while design, installation and commissioning remain the responsibility of a designer or installer.
What do we supply from the Raychem range?
| Product | Description |
|---|---|
| BTV and QTVR self-regulating cables | Parallel self-regulating cables for tracing pipes and vessels. QTVR maintains process temperatures of up to 110 °C, has a fluoropolymer jacket and is supplied in output versions such as 10QTVR2-CT, 15QTVR2-CT and 20QTVR2-CT. |
| XTV(R), HTV and VPL cables | XTV(R) and HTV are self-regulating families from the same range, while VPL is a power-limiting cable. At 480 V, VPL must be used only with controllers that provide ground-fault protection, such as 920, Elexant 4020i, NGC-30 or NGC-40. |
| Elexant controllers | The Elexant 3500i electronic thermostat, with RS-485 and Bluetooth communication options and ground-fault detection, and the Elexant 4020i controller, for monitoring and DCS integration. |
| Solutions for long pipelines and tanks | Complete systems for long pipelines with skin effect heating, optical fibre for a continuous temperature profile and Pipeline Supervisor software, plus tank heating solutions with cables or heating plates. |
Why Raychem?
- Four cable technologies — self-regulating, power-limiting, mineral-insulated and skin effect, chosen according to the required output and exposure temperature
- Maintained temperatures of up to about 650 °C — for demanding processes, with exposure of up to about 1000 °C, depending on the technology chosen
- Very long pipelines — integrated systems with circuits of up to 50 km, and skin effect heating (STS) reaches 260 °C
- Scalable control and monitoring — from a simple thermostat to controllers with DCS integration, early warnings and preventive maintenance
- Design tools — TraceCalc Net for simple systems and TraceCalc Pro for large projects
Which Raychem codes and series are requested most often?
| Code | Description |
|---|---|
| BTV-CR | Parallel self-regulating cable for industrial tracing |
| BTV-CT | Parallel self-regulating cable, CT version |
| LBTV | Self-regulating cable, LBTV version |
| 10QTVR2-CT | Self-regulating cable, maintenance up to 110 °C, 230 V AC |
| 15QTVR2-CT | Self-regulating cable, maintenance up to 110 °C, 230 V AC |
| 20QTVR2-CT | Self-regulating cable, maintenance up to 110 °C, 230 V AC |
| XTV(R)-CT | Self-regulating cable, XTV(R) family |
| HTV-CT | Self-regulating cable, HTV family |
| VPL-CT | Power-limiting cable, high output |
| Elexant 3500i | Electronic thermostat for tracing |
| Raychem 920 | Controller with ground-fault protection |
| Elexant 4020i | Controller for tracing circuits |
| NGC-30 / NGC-40 | Controllers for tracing circuits |
| TraceCalc Pro | Design software for large tracing projects |
Where is Raychem equipment used?
- Chemicals and petrochemicals — process temperature maintenance and freeze protection on process lines
- Oil and gas, LNG — tracing for pipelines and equipment, including explosive atmosphere areas
- Power generation — electric tracing for plant installations
- Food and pharmaceutical — maintaining fluid temperature in pipes and tanks
- Buildings and infrastructure — freeze protection, snow melting and leak detection
How do we supply Raychem in Romania?
For Raychem electric tracing we can prepare quotations for cables, connection kits, thermostats and controllers. Items are supplied to order, usually in 1–4 weeks, and systems sized per project may have a longer lead time. For a correct quotation, the following are useful: the length and diameter of the pipe, the thickness and type of insulation, the maintained temperature and the minimum ambient temperature, the supply voltage, the Ex zone and, for replacements, the cable designation from the junction box (for example BTV or QTVR).
The sizing of a tracing circuit and the approvals for a given area are confirmed on the basis of the design calculation.
Frequently asked questions about Raychem
What does Raychem make?
Raychem makes electrical heat tracing systems: self-regulating, power-limiting, mineral-insulated or skin effect cables, connection kits, thermostats and controllers, leak detection solutions and design software. The brand may still be found under a previous name.
How do I choose between a self-regulating cable and a power-limiting one?
A self-regulating cable reduces its output as the pipe warms up, so it suits temperature maintenance with a low risk of overheating. A power-limiting cable is chosen for high output and high exposure temperatures. Tell us the maintained temperature, the maximum exposure and the circuit length.
Can you supply Raychem electric tracing in Romania, and within what lead time?
Yes, to order. To order, the lead time is usually 1–4 weeks, and systems sized per project may need longer. Items can ship in 24–72 h when the item is in stock, locally or at the supplier; the exact lead time appears in the quotation.
Can I replace an existing BTV or QTVR cable?
We confirm equivalences only after checking, as each family has a different output and a different temperature limit. QTVR holds up to 110 °C and can be installed down to −60 °C. We need the full designation from the cable (with the output figure and the suffix), the voltage and the type of the existing connection kit.
What details do you need for a quotation on a tracing system?
For a quotation, the useful details are the length and diameter of the pipe, the thickness and material of the insulation, the maintained temperature, the minimum ambient temperature, the fluid, the available voltage, the Ex zone and the number of circuits. For replacements, add the designation of the existing cable and controller.
How do I request a Raychem quotation?
Send the Raychem code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Chemelex, Chemelex Raychem (manufacturer documentation)