Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Robur supplier in Romania

For Robur we offer GAHP A Plus, AR Plus, GS Plus and WS Plus absorption heat pumps, ACF and ACF HR chillers, Robur Hybrid systems and Next-G unit heaters, starting from the thermal load and the flow and return temperatures.

Headquarters: Verdellino/Zingonia (Bergamo), Italy

Request a quote

Who is Robur and what does it make?

Robur is an Italian manufacturer headquartered in Verdellino/Zingonia, near Bergamo, specialising in heating and cooling with natural gas. The range includes gas absorption heat pumps from the GAHP A Plus, AR Plus, GS Plus and WS Plus series, ACF and ACF HR gas absorption chillers, Robur Hybrid gas-electric hybrid systems, electric heat pumps, Next-G and Next-R gas unit heaters, gas convectors, AD evaporative coolers, air curtains, AY condensing boilers and cascade modules.

The GAHP heat pumps extract heat from air (A Plus and AR Plus), from the ground (GS Plus) or from water (WS Plus). A Plus is modulating, with a condensing burner, AR Plus is reversible for heating and cooling, GS Plus can cool in free-cooling mode, and WS Plus produces hot water and cold water simultaneously. All use a natural refrigerant, so they fall outside the scope of the F-Gas regulation, and can be managed remotely. The ACF HR chiller recovers heat for domestic hot water, up to 32 kW, during cooling; the ACF TK (processes), ACF LB (industrial refrigeration) and ACF HT (hot climate) variants cover special applications. The almost static absorption cycle does not need periodic refilling of the refrigerant.

The equipment is found in production halls, warehouses, commercial and public buildings, as a replacement for or complement to boilers and electric chillers. The offer starts from the heating and cooling load, the flow and return temperatures, the energy source (air, ground or water) and the installation location, indoors or outdoors.

What do we supply from the Robur range?

ProductDescription
GAHP A Plus and AR Plus absorption heat pumpsHeat pumps using natural gas and energy from air: A Plus, modulating with a condensing burner, for heating and domestic hot water; AR Plus, reversible, for heating and cooling. They are supplied in a standard or low-noise version.
GAHP GS Plus and WS Plus heat pumpsGS Plus uses geothermal energy through probes and can cool in free-cooling mode; WS Plus uses hydrothermal energy and produces hot and cold water simultaneously, or for process circuits. Both are available for indoor and outdoor installation.
ACF and ACF HR gas absorption chillersChillers for outdoor installation, with low electrical energy consumption, independent and modular. ACF HR recovers heat for domestic hot water, up to 32 kW; the TK, LB and HT variants are intended for processes, industrial refrigeration and hot climates.
Robur Hybrid, Next-G unit heaters and AD coolersGas-electric hybrid systems for heating and cooling, Next-G (condensing) and Next-R gas unit heaters for halls, and AD evaporative coolers, which cool the air by evaporating water and also work with the doors open.

Why Robur?

  • GAHP absorption heat pumps — variants for air (A Plus, AR Plus), ground (GS Plus) and water (WS Plus), in standard or low-noise versions
  • AR Plus reversible heat pump — heating and cooling with low electrical energy demand, for buildings with limited available electrical power
  • ACF chiller with heat recovery — ACF HR produces up to 32 kW of hot water during cooling; ACF TK, LB and HT for processes, industrial refrigeration and hot climates
  • Natural refrigerant — gas absorption falls outside the scope of the F-Gas regulation, and the almost static cycle does not need periodic refilling
  • Pre-assembled groups and centralised control — cascade modules, DDC controllers and remote management for higher-power configurations

Which Robur codes and series are requested most often?

CodeDescription
GAHP A PlusGas absorption heat pump, energy from air, modulating
GAHP A Plus 60 HzGAHP A Plus version for a 60 Hz network
GAHP AR PlusReversible gas absorption heat pump
GAHP GS PlusGas absorption heat pump, geothermal energy
GAHP WS PlusGas absorption heat pump, hydrothermal energy
GA ACFGas absorption chiller
GA ACF HRAbsorption chiller with heat recovery, up to 32 kW
ACF TKACF chiller for process applications
ACF LBACF chiller for industrial refrigeration
ACF HTACF chiller for hot climates
Robur HybridGas-electric hybrid system with heat pump
e-NextHydroElectric air-water system
Next-GGas unit heater, condensing, wall-mounted
Next-RGas unit heater from the Next-R series
ADEvaporative cooler for halls
AY CondensingCondensing boiler

Where is Robur equipment used?

  • Industrial halls and warehouses — heating with gas unit heaters and cooling with evaporative coolers
  • Commercial and public buildings — absorption heat pumps for heating, cooling and domestic hot water
  • Industrial processes — ACF TK chillers and WS Plus for simultaneous hot and cold water production
  • Industrial refrigeration — ACF LB chillers
  • Buildings with several energy sources — Robur Hybrid hybrid systems and cascade modules

How do we supply Robur in Romania?

From the Robur range we can offer GAHP heat pumps, ACF and ACF HR absorption chillers, Robur Hybrid systems, Next-G and Next-R unit heaters, AD coolers and spare parts for existing units. Robur units arrive to order, usually in 1–4 weeks; for pre-assembled groups, depending on the specification, the lead time may be longer. For a quotation, send the heating and cooling load, the flow and return temperatures, the energy source, the type of gas available, the installation location (indoors or outdoors) and, for a replacement, the code from the unit nameplate.

Connection to the gas network, approvals for gas installations and commissioning remain the responsibility of the customer and the certified gas installer.

Frequently asked questions about Robur

What does Robur make?

Robur makes natural gas heating and cooling equipment: GAHP absorption heat pumps, ACF absorption chillers, gas-electric hybrid systems, gas unit heaters, evaporative coolers and condensing boilers. The headquarters are in Verdellino/Zingonia, near Bergamo, in Italy.

How do I choose between GAHP A Plus, AR Plus, GS Plus and WS Plus?

The energy source decides: air for A Plus and AR Plus, ground for GS Plus, water for WS Plus. AR Plus is reversible and needs little electrical energy, and WS Plus produces hot and cold water simultaneously. Send the loads, the temperatures and the available source so that the series can be checked.

Do you supply Robur equipment in Romania, and how fast?

Yes. Items can ship in 24–72 h when the item is in stock, locally or at the supplier; units are usually brought in to order, in 1–4 weeks. Depending on the specification, the lead time may be longer for pre-assembled groups or special versions; we confirm it in the quotation.

Can I replace an old Robur chiller or heat pump with a current series?

Compatibility is checked case by case. What matters is the load, the source type, the hydraulic connections, the electrical supply and the installation location. Send a photo of the nameplate, the type and year of the unit, the power and the existing connections, and we check the suitable series before the final quotation.

What data should I send for a quotation on an ACF chiller?

We need the cooling capacity, the chilled water temperatures, the type of application (comfort, process or industrial refrigeration), the climate and the maximum outdoor air temperature, the gas available, whether you want heat recovery for hot water and any noise requirements.

How do I request a Robur quotation?

Send the Robur code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Robur S.p.A. (manufacturer documentation)