Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

SINGLE Temperiertechnik supplier in Romania

For SINGLE Temperiertechnik we quote WT3 and WT4 water temperature control units, Oil Advanced D0–D4 oil units, Chill Advanced chillers and Variotherm ATT systems, based on the temperature, heating power and flow required.

Founded in 1968 · Headquarters: Hochdorf, Germany

Request a quote

Who is SINGLE Temperiertechnik and what does it make?

SINGLE Temperiertechnik was founded in 1968; its first temperature control unit had been developed in 1955. It is based in Hochdorf, Germany, with its own companies in Europe, North America and Asia. The company builds water and oil temperature control units, chillers and variable temperature control systems, used where a process requires a stable fluid temperature.

The temperature control unit is often the piece next to the mould of an injection moulding machine or a press, or next to a test bench. The water units run from the 90 °C class of the compact WT3 and WT4 series up to 200 °C, while the oil units reach 350 °C without overpressure, with the Oil Advanced families D0 (180–300 °C) and D1–D4 (300–350 °C). The Chill Advanced C-14, C-20, C-25 and C-40 chillers have average capacities of 14, 20, 25 and 40 kW at a flow temperature of 10 °C, in air-cooled or water-cooled versions.

The Variotherm ATT system, in the H (200 °C), N1 and S (180 °C) versions, alternates hot and cold water through the mould, which allows differences of over 100 °C in critical zones. Semiconductors, batteries, plastics, chemicals and pharmaceuticals, packaging and the food industry are sectors where these units are frequently found, and the company also has maintenance and inspection services for pressure equipment.

What do we supply from the SINGLE Temperiertechnik range?

ProductDescription
Water temperature control unitsUnits for temperatures from 90 to 200 °C, with compact WT3 and WT4 series of the 90 °C class and versions with overpressure for higher temperatures, which shorten cycles through fast heat transfer, with intelligent controllers.
Oil temperature control unitsThe Oil Advanced family: D0 for 180–300 °C and D1, D2, D3, D4 for 300–350 °C, with no overpressure in the circuit, for high-temperature processes where water is no longer an option.
Chill Advanced chillersCooling systems with their own refrigeration circuit, with average capacities of 14, 20, 25 and 40 kW at a flow temperature of 10 °C, a temperature range from −5 to +30 °C, air-cooled (L) or water-cooled (W) versions, plus the compact CT3 series.
Variotherm ATTVariable temperature control system for injection and pressing moulds, in the ATT H (200 °C), ATT N1 and ATT S (180 °C) versions, which alternate hot and cold circuits through the same heat transfer fluid.

Why SINGLE Temperiertechnik?

  • Water, oil and cooling in one programme — temperature control units from 90 to 350 °C and chillers, without combining equipment from several makers
  • Oil without overpressure — the Oil Advanced D0–D4 families run without pressure in the circuit up to 350 °C, so no pressurisation equipment is needed
  • Variotherm ATT — two circuits with the same water at different temperatures, for differences of over 100 °C in the mould
  • Compact WT3 and WT4 series — 90 °C units, with intelligent control, careful thermal insulation and a housing with optimised flow
  • Configurations to order — besides standard units, the company builds systems for OEMs and for test benches

Which SINGLE Temperiertechnik codes and series are requested most often?

CodeDescription
WT3 / 90 °CCompact water temperature control unit, 90 °C class
WT4 / 90 °CCompact water temperature control unit, 90 °C class
Oil Advanced D0Oil temperature control unit, 180–300 °C
Oil Advanced D1Oil temperature control unit, 300–350 °C
Oil Advanced D2Oil temperature control unit, 300–350 °C
Oil Advanced D3Oil temperature control unit, 300–350 °C
Oil Advanced D4Oil temperature control unit, 300–350 °C
Chill Advanced C-1414 kW chiller, air-cooled or water-cooled
Chill Advanced C-2020 kW chiller, air-cooled or water-cooled
Chill Advanced C-2525 kW chiller, air-cooled or water-cooled
Chill Advanced C-4040 kW chiller, air-cooled or water-cooled
Chill Compact CT3Compact chiller, recently announced series
Variotherm ATT HVariable temperature control system, 200 °C
Variotherm ATT N1Variable temperature control system, 180 °C
Variotherm ATT SVariable temperature control system, 180 °C

Where is SINGLE Temperiertechnik equipment used?

  • Plastics and elastomers — temperature control of injection and pressing moulds
  • Chemicals and pharmaceuticals — temperature control of high-temperature processes
  • Semiconductors and batteries — exact temperature control in sensitive processes
  • Automotive and electromobility — test benches with variable temperature control
  • Packaging and food — process cooling with chillers

How do we supply SINGLE Temperiertechnik in Romania?

We can quote SINGLE water or oil temperature control units, Chill Advanced chillers and parts for existing units, starting from the unit nameplate or from a process requirement. Supply is to order, usually 1–4 weeks for standard units; depending on the specification, the lead time may be longer. For a quotation we need the fluid, the maximum temperature, the heating and cooling power, the pump flow and pressure, the type of cooling (air or water) and the dimensions of the mould or of the consumer.

The replacement of an old unit is confirmed in the quotation, on the basis of the nameplate and the process data (fluid, temperature, flow, pressure).

Frequently asked questions about SINGLE Temperiertechnik

What does SINGLE Temperiertechnik make?

The company from Hochdorf, active since 1968, builds water and oil temperature control units, industrial chillers, Variotherm ATT variable temperature control systems, water manifolds and installations for test benches, intended for processes with strict temperature requirements.

When do I choose an oil unit instead of a water unit?

Water units cover processes up to 200 °C, while oil goes beyond 200 °C and reaches 350 °C without overpressure. Tell us the working temperature, the power required and the material in the circuit; the suitable family is then identified, for example Oil Advanced D0 or D1–D4.

Do you supply SINGLE units in Romania, and how quickly?

Yes, to order; usually 1–4 weeks for standard units. For configured systems or for test benches the lead time may be longer, and the exact value appears in the quotation issued after the request is checked.

Can I replace an old temperature control unit with a current one?

It depends on the fluid, the heating power, the flow, the pump pressure and the connections. Equivalence is established after checking: send us the unit nameplate, a photo and the process data, and we then see whether a current series, such as WT3 or Oil Advanced, fits.

What data do I need to send for a chiller quotation?

Send the cooling power in kW at the flow temperature wanted, the temperature range, the type of cooling (air or water), the flow and pressure required, the fluid and the supply voltage. For the Chill Advanced series, also say whether you prefer the C-14, C-20, C-25 or C-40 version.

How do I request a SINGLE Temperiertechnik quotation?

Send the SINGLE Temperiertechnik code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: SINGLE Group GmbH (manufacturer documentation)