Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Thermal Care supplier in Romania

For Thermal Care we quote Slim SCA and SCW compact chillers, CW central chillers, Easytherm temperature controllers and Aryacool+ adiabatic coolers; we need the nameplate model, the power in kW and the medium temperature.

Request a quote

Who is Thermal Care and what does it make?

Thermal Care makes cooling and temperature-control equipment for industrial processes: portable and compact chillers, water-cooled or air-cooled central chillers, cooling towers and adiabatic coolers, mould temperature controllers and pumping units. The equipment keeps the temperature of water or oil in the circuits of injection moulding machines and extruders, heat treatment and induction installations, plating lines and chemical or food processes. For a quotation, send us the model and serial number from the nameplate, the cooling power required in kW and the working temperature of the medium.

The compact chillers cover small and medium capacities: the CH series (6.6–57 kW), Accuchiller NQA (24–47 kW), the air-cooled Slim SCA (11–120 kW) and the water-cooled Slim SCW (12–68 kW). For central installations there are the CAPchiller CCW (9–50 kW) and the water-cooled CW series, with models CW 0621–1921 (74–230 kW), CW 2442–3942 (290–460 kW) and CW 4222–8822 (511–1060 kW), the latter with screw compressors and two refrigeration circuits. Outdoor installations use the air-cooled CA, KSA, Ecosmart CA and Easycool+ ECA chillers, while the Aryacool+ adiabatic coolers and towers handle 190–1300 kW.

The temperature controllers have pumps of 0.75–4 kW, heaters of 6–36 kW, a cooling valve and a PID controller, and are chosen by heat-transfer medium: water, oil or vacuum operation. The Easytherm EP, EW and EO series cover these variants, Easytherm Flow works with high water flow rates up to 140 °C, and DigitempEVO combines the temperature controller with a water-cooled chiller. Vacuum units stop water losses from a cracked mould without drawing air into the circuit. Production holds certifications as stated in the manufacturer's documentation.

What do we supply from the Thermal Care range?

ProductDescription
CH, NQA, SCA and SCW compact chillersChillers for a single machine or work cell: the CH series of 6.6–57 kW, Accuchiller NQA of 24–47 kW, air-cooled Slim SCA of 11–120 kW and water-cooled Slim SCW of 12–68 kW.
CW central chillersWater-cooled chillers for low-temperature process water: CW 0621–1921 of 74–230 kW, CW 2442–3942 of 290–460 kW and CW 4222–8822 of 511–1060 kW, with screw compressors and two refrigeration circuits on the large models.
Easytherm temperature controllersUnits with a 0.75–4 kW pump, a 6–36 kW heater and a PID controller, in the EP, EW and EO series, plus Easytherm Flow for high water flow rates up to 140 °C, used for mould temperature control.
Aryacool+ and outdoor chillersAryacool+ adiabatic coolers and cooling towers of 190–1300 kW and air-cooled CA, KSA, Ecosmart CA and Easycool+ ECA chillers, installed outdoors for central circuits. Sizing is based on the total circuit power and the outdoor air temperature.

Why Thermal Care?

  • Range from 6.6 kW (CH series) to over 1000 kW (CW 4222–8822) — from a single machine to a central circuit
  • Large CW chillers with screw compressors and two refrigeration circuits — for central circuits of 511–1060 kW
  • Temperature controllers for water, oil or vacuum — the heat-transfer medium is chosen by the mould temperature
  • DigitempEVO with integrated chiller — temperature control and cooling in one unit next to the machine
  • Aryacool+ towers and adiabatic coolers — the cooling circuit is completed from the same list of codes

Which Thermal Care codes and series are requested most often?

CodeDescription
CH50–480CH series compact chillers, 6.6–57 kW
NQAAccuchiller chillers, 24–47 kW
SCA 1111Air-cooled Slim chiller, 11 kW
SCA 6411–8711Air-cooled Slim chillers, 64–87 kW
SCW 1211–4511Water-cooled Slim chillers, 12–45 kW
CCW 09–50CAPchiller central, 9–50 kW
CW 0621–1921Water-cooled central chillers, 74–230 kW
CW 4222–8822Central screw chillers, 511–1060 kW
CA 4222–7622Outdoor air-cooled chillers, 432–910 kW
Aryacool+Adiabatic cooler and cooling tower, 190–1300 kW
Easytherm FlowHigh water flow temperature controller, up to 140 °C
DigitempEVOTemperature controller combined with a water-cooled chiller

Where is Thermal Care equipment used?

  • Plastics processing — cooling of moulds and extruders
  • Die casting — temperature control of moulds with water or oil
  • Heat treatment and induction — cooling of inductors and power sources
  • Plating and anodising — bath temperature control
  • Food and beverage industry — glycol chillers for processes

How do we supply Thermal Care in Romania?

We can quote Thermal Care chillers, temperature controllers and adiabatic coolers, as well as spare parts for existing units. It helps us to have the model and serial number from the nameplate, the cooling or heating power required, the medium temperature, the condenser cooling type (air or water) and the mains voltage. We supply them to order; usual spare parts typically take 1–4 weeks, while for large central chillers the lead time may be longer, depending on the specification. The exact lead time is confirmed in the quotation.

A central chiller is sized from the heat balance of the machines served and the cooling-water temperature available on site.

Frequently asked questions about Thermal Care

What does Thermal Care make?

Thermal Care makes equipment for process cooling and temperature control: portable and compact chillers, water-cooled or air-cooled central chillers, cooling towers and adiabatic coolers, mould temperature controllers and pumping units, used mainly in the plastics industry and in industrial processes.

How do I choose the capacity of a Thermal Care chiller?

We start from the heat removed from the machines served, the process water temperature, the ambient or condenser cooling-water temperature and any planned extensions. For a single machine the CH or Slim series fit, while for a central circuit the CW or the outdoor CA and Easycool+ chillers fit.

How soon do we get spare parts or a Thermal Care chiller?

Spare parts can ship in 24–72 h when the item is in stock, locally or at the supplier, and the others are supplied to order, usually in 1–4 weeks. For central chillers or large adiabatic coolers the lead time may be longer, depending on the specification.

What can I do if my temperature controller no longer holds the temperature?

Send us the model and serial number from the nameplate and a description of the fault (pump, heater, cooling valve, controller). We check the available spare parts; if the unit is old, we suggest an Easytherm or DigitempEVO model with the same power and the same heat-transfer medium.

What data should I send for a quotation on a Thermal Care central chiller?

The total cooling power, the outlet water temperature, the circuit flow rate, the condenser type (air or water), the available space, the mains voltage and whether you want a reserve on separate refrigeration circuits. For replacing an existing chiller, its nameplate and the current circuit flow rate help us keep the connections.

How do I request a Thermal Care quotation?

Send the Thermal Care code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Thermal Care (manufacturer documentation)