Wesper supplier in Romania
For Wesper we quote PREMIAIR, AIRTWIN and Wespak air handling units, WESTHERM unit heaters, TEC and HPL fan coil units, finned coils and LAWC/LAWH air conditioners; we need the airflow and the type of heat-transfer medium.
Founded in 1948 · Headquarters: Pons, France
Who is Wesper and what does it make?
Wesper is a company from France with experience in air conditioning and air handling equipment since 1948. The plant at Pons, with 6,000 m² of production on an industrial site of 55,000 m², makes unit heaters, coil heat exchangers and air handling units for commercial, industrial and tertiary applications.
The PREMIAIR air handling units come in ten sizes, from 1,000 to 40,000 m³/h, with a modular self-supporting structure, single or double flow, and AIRTWIN has five sizes, from 20,000 to 100,000 m³/h, with an aluminium structure. Wespak is the compact version, in three sizes (1.39, 2.69 and 3.99), from 500 to 4,400 m³/h, with horizontal or vertical mounting and coils with hot water, cold water, steam, direct expansion or electric. Finned coils are made to order, for hot water, cold water, steam or direct expansion.
The WESTHERM unit heaters cover 740–18,000 m³/h, in six three-phase 400 V models and four single-phase 230 V models, with hot water, chilled water, steam or electric heating. The TEC and HPL fan coil units have nine sizes between 105 and 1,500 m³/h. The LAWC and LAWH air conditioners range from 2 to 41 kW, the RLCE chiller units from 6 to 50 kW and the LGAC/LGAH units from 20 to 190 kW. What matters for a quotation is the airflow and the type of heat-transfer medium.
What do we supply from the Wesper range?
| Product | Description |
|---|---|
| PREMIAIR, AIRTWIN and Wespak air handling units | Modular units with a self-supporting structure, single or double flow. PREMIAIR: 1,000–40,000 m³/h, AIRTWIN: 20,000–100,000 m³/h with an aluminium structure, compact Wespak of 500–4,400 m³/h. |
| WESTHERM unit heaters | Unit heaters with an airflow of 740–18,000 m³/h, in six three-phase 400 V models and four single-phase 230 V models with an ECM fan, with hot water, chilled water, steam or electric heating, for ceiling or wall mounting. |
| Finned coils | Coil heat exchangers made to order, small or large, for hot water, cold water, steam or direct expansion, with different surface treatments, for air handling units, fan coil units and process installations. |
| Fan coil units, air conditioners and chiller units | TEC and HPL fan coil units (105–1,500 m³/h), FHW wall cassettes, LAWC/LAWH air conditioners of 2–41 kW with water condensing, RLCE/RLCA chiller units and LGAC/LGAH chilled water units of 20–190 kW. |
Why Wesper?
- PREMIAIR from 1,000 to 40,000 m³/h and AIRTWIN up to 100,000 m³/h — the same type of modular unit for small and very large airflows
- Compact Wespak, from 500 to 4,400 m³/h, with horizontal (under ceiling) or vertical (wall) mounting — it adapts to the installation location
- Finned coils made to order for hot water, cold water, steam or direct expansion — a worn coil is replaced by dimensions
- WESTHERM unit heaters of 740–18,000 m³/h, with hot water, chilled water, steam or electric — heating for halls and workshops
- TEC and HPL fan coil units with AC (alternating current) or EC (electronically commutated) fan versions and available pressure of up to 80 Pa — chosen by operating regime
Which Wesper codes and series are requested most often?
| Code | Description |
|---|---|
| PREMIAIR | Air handling unit, 1,000–40,000 m³/h |
| AIRTWIN | Unit with aluminium structure, 20,000–100,000 m³/h |
| Wespak | Compact unit, 500–4,400 m³/h |
| WESTHERM | Unit heaters of 740–18,000 m³/h |
| TEC | Fan coil unit, 105–1,500 m³/h |
| HPL | Fan coil unit for air ducts |
| FHW | Wall cassette, 205–790 m³/h |
| K7W | Ceiling cassette, 310–1,820 m³/h |
| LAWC / LAWH | Horizontal monobloc air conditioners with water condensing, 2–41 kW |
| RLCE | Chiller unit with water condensing, 6–50 kW |
| RLCA | Chiller unit with air condensing, 8–20 kW |
| LGAC / LGAH | Chilled water unit and air-to-water heat pump, 20–190 kW |
Where is Wesper equipment used?
- Industrial and commercial spaces — heating with WESTHERM unit heaters
- Industrial and tertiary buildings — PREMIAIR and AIRTWIN air handling units
- Process cooling and heating installations — made-to-order finned coils
- Tertiary buildings — TEC fan coil units and K7W cassettes
- Chilled water production — LGAC units for installations requiring 20–190 kW
How do we supply Wesper in Romania?
We can quote Wesper equipment for heating, cooling and air handling installations. For an accurate quotation, send the airflow, the type of heat-transfer medium (hot water, cold water, steam, direct expansion or electric), the temperature regime and the dimensions of the coil or of the existing unit. For replacement coils, add the frame dimensions, the number of tube rows and the fin pitch; for unit heaters, the voltage (400 V or 230 V). Equipment is supplied to order for each project, usually in 1–4 weeks, and the lead time can be longer, depending on the configuration requested; the exact date is given in the quotation.
Made-to-order coils and units are confirmed in the quotation, based on the dimensions and thermal regimes received.
Frequently asked questions about Wesper
What does Wesper make?
Since 1948, Wesper has made unit heaters, coil heat exchangers, air handling units, fan coil units, air conditioners, chiller units and heat pumps. The plant is at Pons, in France, and the equipment is used in commercial, industrial and tertiary buildings.
How do I choose between PREMIAIR and AIRTWIN?
PREMIAIR covers airflows of 1,000–40,000 m³/h, and AIRTWIN 20,000–100,000 m³/h, with an aluminium structure. The choice depends on the airflow, the installation space and the configuration required. Send the airflow and the heat-transfer media, and we identify the suitable series.
Is Wesper equipment supplied in Romania, and how quickly?
Delivery is usually within 1–4 weeks of the order, but made-to-measure coils and units can take longer. An item can ship in 24–72 h when the item is in stock, locally or at the supplier. The exact lead time is given in the quotation.
Can I replace an old heating or cooling coil with a Wesper one?
Yes, if we have the data of the old coil: coils are made to order, so we need the frame dimensions, the number of rows, the fin pitch, the type of medium (water, steam, direct expansion) and the connections. With a photo and the measurements we confirm the suitable version.
What do I need to send for a quotation on a TEC or HPL fan coil unit?
Send the airflow required (105–1,500 m³/h), the two-pipe or four-pipe installation type, the fan version (AC or EC), the mounting type (wall or ceiling) and the available pressure at the ducts, if applicable. A simple drawing shortens the check.
How do I request a Wesper quotation?
Send the Wesper code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Wesper (manufacturer documentation)