Aermec supplier in Romania
For Aermec we quote NSM and NSMJ screw chillers, NSM_F and NRB free-cooling units, NRL and ANL scroll chillers and NRK, NXW and WRL heat pumps; for a quotation we need the capacity, refrigerant, water temperatures and the series from the nameplate.
Founded in 1961 · Headquarters: Bevilacqua (Verona), Italy
Who is Aermec and what does it make?
Aermec is an Italian manufacturer of air-conditioning equipment, founded in 1961, based at Bevilacqua, in the province of Verona. The range includes air-to-water and water-to-water chillers and heat pumps for large installations, from commercial and industrial buildings to process cooling: screw compressor units, free-cooling chillers, scroll compressor units and reversible heat pumps.
At large capacities, Aermec offers the NSM chillers, with two or three circuits, twin-screw compressors and R134a or R513A refrigerant, for cooling capacities between 302 and 2100 kW. NSMJ uses variable-speed screw compressors with an integrated inverter, for R513A and 293.6–1417 kW. The free-cooling versions, NSM_F and NRB, use low outdoor air temperature to limit or eliminate compressor operation; NRB covers 212–967 kW with scroll compressors and a plate heat exchanger. For medium and small capacities there are NRL (53–82.8 kW) and ANL (5.7–43 kW), both with scroll compressors and R410A refrigerant. The NRK reversible air-to-water heat pump produces hot water up to 65 °C and works with outdoor air down to -20 °C, while NXW and WRL are water-side reversible heat pumps for indoor installations.
Such units appear in office buildings, shopping centres, production halls and data centres, where the chillers cool the building or process water. For parts and accessories, the unit type and the series from the nameplate matter.
What do we supply from the Aermec range?
| Product | Description |
|---|---|
| NSM and NSMJ | Air-cooled chillers for outdoor installation, with twin-screw compressors. NSM has two or three circuits and 302–2100 kW; NSMJ has variable speed with an integrated inverter, R513A and 293.6–1417 kW. Both have axial fans, microchannel coils and a shell-and-tube heat exchanger. |
| NSM_F and NRB free-cooling chillers | Chillers with an additional free-cooling coil, which uses the low outdoor air temperature to cool the return water from the installation. NSM_F has 309–1752 kW in free cooling; NRB has 212–967 kW, scroll compressors and microchannel coils. |
| NRL and ANL with scroll compressors | Air-to-water chillers for outdoor installation, with R410A refrigerant. ANL has one circuit and 5.7–43 kW, NRL has two circuits and 53–82.8 kW. Heat recovery, a pump kit, a water tank and network operation are available as options. |
| NRK, NXW and WRL heat pumps | NRK is a reversible air-to-water heat pump of 18–148 kW in cooling and 21–175 kW in heating, with hot water up to 65 °C. NXW (111.6–510.2 kW) and WRL (6.7–43.7 kW) are water-side reversible units, for indoor installation. |
Why Aermec?
- Screw chillers for 300–2100 kW — NSM with two or three circuits, with R134a or R513A refrigerant, air cooling and a shell-and-tube heat exchanger
- NSMJ with variable-speed screw compressors — integrated inverter and R513A refrigerant, for part-load operation
- Free cooling on NSM_F and NRB — using cold outdoor air to limit compressor operation, with free-cooling capacities of up to 1752 kW (NSM_F)
- Scroll from 5.7 to 82.8 kW — ANL with one circuit and NRL with two circuits, with heat recovery, pump kit and water tank options
- Reversible heat pumps — NRK for hot water at 65 °C and outdoor air down to -20 °C, NXW and WRL for applications with a geothermal source
Which Aermec codes and series are requested most often?
| Code | Description |
|---|---|
| NSM | Screw chiller, 302–2100 kW, R134a or R513A |
| NSM_F | Screw chiller with free cooling, free-cooling capacity 309–1752 kW |
| NSMJ | Screw chiller with inverter, R513A, 293.6–1417 kW |
| NRB | Scroll chiller with free cooling, 212–967 kW |
| NRL | Scroll chiller with two circuits, 53–82.8 kW, R410A |
| ANL | Scroll chiller with one circuit, 5.7–43 kW, R410A |
| NRK | Reversible air-to-water heat pump, 18–148 kW |
| NXW | Water-side reversible heat pump, 111.6–510.2 kW |
| WRL | Water-side reversible heat pump, 6.7–43.7 kW |
Where is Aermec equipment used?
- Commercial buildings and offices — NSM, NRL and ANL chillers for cooling the building water
- Data centres — high-capacity and free-cooling chillers
- Public buildings — heat pumps and chillers for comfort and hot water
- Industry — process water cooling with NSM, NSMJ and NRB units
- Hotels and service buildings — heat pumps and chillers for heating and cooling
How do we supply Aermec in Romania?
We can quote Aermec units from the NSM, NSMJ, NRB, NRL, ANL, NRK, NXW and WRL families, as well as parts and accessories for units in service. For a quotation we need the required cooling or heating capacity, the refrigerant, the water temperature regime, the installation environment (outdoor or indoor), the options wanted (heat recovery, pump kit, low-noise version) and, for an existing unit, the series from the nameplate. We supply to order; usually 1–4 weeks for parts, while for complete units, depending on the specification, the lead time may be longer. The exact lead time is confirmed in the quotation.
The availability of an option or a part for an older Aermec unit is established from the series on the nameplate and the configuration code.
Frequently asked questions about Aermec
Which Aermec products are covered here?
Chillers and heat pumps are covered: the NSM, NSMJ, NSM_F, NRB, NRL and ANL series for water cooling and the NRK, NXW and WRL series for reversible heat pumps. The company's terminal units and air handling units are outside our offer.
How do I choose between an NSM and an NSMJ screw chiller?
NSM has two or three circuits and works at 302–2100 kW with R134a or R513A refrigerant. NSMJ has variable-speed compressors and an integrated inverter, uses R513A and covers 293.6–1417 kW. Send us the cooling capacity, the water temperatures and the load profile.
Can you bring Aermec units to Romania, and how long does it take?
Yes, to order. Parts usually arrive in 1–4 weeks, while a complete unit has a longer lead time, which we set in the quotation once the capacity, options and temperature regime are fixed.
What does free cooling mean, and when is an NRB or an NSM_F worthwhile?
Free cooling uses the low outdoor air temperature to cool the water in the installation, so the compressors work less or not at all. The choice depends on the water temperature and the number of hours with cold air. Send us the operating regime of the installation.
What data do I need to send for parts for an existing Aermec chiller?
We need the unit model (for example NRL or NSM), the series from the nameplate, the refrigerant and the approximate year. With these we request the parts list and check the required reference. We confirm the compatibility of a part on the basis of this data.
How do I request a Aermec quotation?
Send the Aermec code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Aermec (manufacturer documentation)