Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

BROAD Group supplier in Romania

For BROAD we quote BH, BDH, BS, BDS, BZ and BE absorption chillers, BD heat pumps and model C magnetic-compressor chillers; for a quotation we need the capacity, the heat source with its temperature and the water regime.

Founded in 1988 · Headquarters: Changsha, China

Request a quote

Who is BROAD Group and what does it make?

BROAD Group is a Chinese manufacturer of absorption chillers and absorption heat pumps, founded in 1988 and based in Changsha. The offer covers only the equipment for producing chilled and hot water: lithium bromide solution absorption chillers, absorption heat pumps, magnetic centrifugal compressor chillers and pre-assembled pump systems. The company's other activities are outside our offer.

An absorption chiller produces cooling from heat, not with an electric compressor. The BH and BDH series, single-effect and double-effect, use hot water or superheated hot water: the standard hot water temperature is 98–88 °C, and that of the superheated water is 180–165 °C. The BS and BDS series use steam from industrial processes, from cogeneration, from biomass combustion or from turbine exhaust steam. BZ is the direct-fired chiller, supplied with natural gas or another fuel and fitted with a low-NOx gas–fuel oil dual-fuel burner, which can also produce 65 °C hot water in winter. The BE series uses hot gases from engines, turbines, fuel cells, industrial furnaces and incinerators, and the BHE and BZHE models combine several heat sources. BD heat pumps recover heat from steam, hot water or flue gases and raise it to a higher temperature; from low-temperature, solar or geothermal sources, they can heat water up to 90 °C.

Model C is a chiller with a centrifugal compressor on magnetic bearings, oil-free. Such equipment is found at cogeneration plants, district heating, industrial platforms with waste heat and process water cooling installations.

What do we supply from the BROAD Group range?

ProductDescription
BH, BDH, BS and BDSSingle-effect or double-effect absorption chillers. BH and BDH use hot or superheated water (98–88 °C standard, 180–165 °C), and BS and BDS use steam. They have a 2-way or 3-way control valve to reduce the heat input at partial loads.
BZ, BE and multi-energy (BHE, BZHE)BZ runs on natural gas or another fuel and with a dual-fuel burner; BE is a double-effect chiller and heater fed with hot gases and with a bypass valve; BHE and BZHE combine hot water and flue gases, with or without direct firing.
BD absorption heat pumpsHeat pumps that capture heat from steam, hot water and flue gases and supply it at a higher temperature to heating networks, and can cool a circuit at the same time. Used for preheating make-up water and for process heat recovery.
Chiller C and pre-assembled pump systemChiller with a magnetic centrifugal compressor, oil-free, supplied pre-assembled with a water distribution system, a metal enclosure and remote monitoring. The pump system is supplied pre-assembled.

Why BROAD Group?

  • Absorption chillers on several heat sources — hot water (BH, BDH), steam (BS, BDS), gas or fuel oil (BZ), flue gases (BE) and combinations (BHE, BZHE)
  • Use of waste heat — cogeneration, industrial processes, solar energy, district heating, biomass and incineration can feed the chiller, so cooling is obtained from heat, not from an electric compressor
  • Direct-fired BZ — gas–fuel oil dual-fuel burner, NOx below 10 ppm and production of 65 °C hot water in the cold season
  • BD absorption heat pumps — recover heat from steam, hot water or flue gases; from solar or geothermal sources they heat water up to 90 °C
  • Model C with magnetic centrifugal compressor, oil-free and frictionless — pre-assembled system with water distribution and remote monitoring

Which BROAD Group codes and series are requested most often?

CodeDescription
BHHot water absorption chiller, single effect
BDHHot water absorption chiller, double effect
BSSteam absorption chiller, single effect
BDSSteam absorption chiller, double effect
BZDirect-fired absorption chiller
BEChiller and heater with flue gases, double effect
BHEMulti-energy chiller: hot water and flue gases
BZHEMulti-energy direct-fired chiller
BDAbsorption heat pump
CMagnetic centrifugal compressor chiller, oil-free

Where is BROAD Group equipment used?

  • Cogeneration and trigeneration — absorption chillers fed with flue gases or hot water from engines and turbines
  • District heating and power plants — absorption heat pumps for recovering condensation heat
  • Process industry — use of steam and waste heat for water cooling
  • Incineration and biomass — cooling produced from the heat of burning waste or biomass
  • Solar and geothermal energy — absorption heat pumps that use low-temperature sources

How do we supply BROAD Group in Romania?

We can quote BROAD absorption chillers and heat pumps, magnetic-compressor chillers and pre-assembled pump systems. For a quotation we need the cooling or heating capacity, the available heat source (hot water, steam, flue gases, natural gas) with its temperature and pressure, the chilled water and cooling water regime, as well as the installation space. Supplied to order, typically in 1–4 weeks for parts; depending on the specification, the lead time may be longer, especially for complete units. The exact lead time is confirmed in the quotation.

The useful capacity of an absorption chiller is established on the basis of the temperature and flow of the heat source and the chilled water regime.

Frequently asked questions about BROAD Group

What does BROAD Group make in the field of chillers?

BROAD makes lithium bromide absorption chillers (BH, BDH, BS, BDS, BZ, BE and the multi-energy models), BD absorption heat pumps and magnetic centrifugal compressor chillers, model C, plus pre-assembled pump systems for water distribution.

How do I choose between BH, BS, BZ and BE?

The choice starts from the heat source. BH and BDH use hot water, BS and BDS steam, BZ natural gas or fuel oil, and BE the hot gases from engines, turbines or furnaces. Send us the available source, its temperature and the cooling capacity wanted.

Can you bring BROAD equipment to Romania and within what time?

Yes, to order. For parts the lead time is typically 1–4 weeks, and complete chillers and heat pumps have a longer lead time, confirmed in the quotation once the capacity, the heat source and the water regime are set.

Can an absorption chiller replace an existing electric chiller?

It depends on the existence of a usable heat source (hot water, steam, flue gases or gas) and on the installation space. For an analysis we need the cooling capacity, the water regime, the available heat source and the nameplate of the current unit, and then we identify the suitable variant.

What data is needed for a BD absorption heat pump?

We need the heat source (steam, hot water, flue gases) with its temperature and flow, the heating capacity wanted, the desired temperature of the delivered water and, where applicable, the need to cool a circuit at the same time. With them we request the configuration.

How do I request a BROAD Group quotation?

Send the BROAD Group code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: BROAD (manufacturer documentation)