CIAT supplier in Romania
For CIAT we quote AQUACIAT and DYNACIAT chillers and heat pumps, CLIMACIAT FLOWAY air handling units, VECTIOS rooftop units, VEXTRA dry coolers and EXPAIR precision units; we need the capacity, the refrigerant and the airflow.
Who is CIAT and what does it make?
CIAT is a French brand of heating, ventilation and air conditioning equipment, with three production centres in Europe: Montluel, near Lyon, for chillers and heat pumps, Culoz for air handling equipment and Montilla, in Spain, for rooftop units and compact solutions. The equipment is used in commercial buildings, hotels, logistics facilities and industrial applications.
For cooling and heating, the programme includes AQUACIAT air-to-water chillers and heat pumps (for example AQUACIAT LD and ILD with R-32, rated 40–160 kW, and AQUACIAT POWER, up to 940 kW), EREBA 17-21 chillers with inverter compressor, the EREBA ACCESS range and DYNACIAT and HYDROCIAT water-cooled units of up to 1,756 kW. For air, there are CLIMACIAT FLOWAY air handling units (300–25,000 m³/h), AIR COMPACT and DFU, VECTIOS and VECTIOS POWER rooftop units, HELIOTHERME 4000 and TPL unit heaters, as well as EXPAIR and MAGISTER precision air conditioning units.
The European centre for control solutions and connected services for HVAC installations is located in Vence. Process installations also use OPERA and VEXTRA dry coolers and air-cooled condensers (up to 2,000 kW), as well as ITEX gasketed plate heat exchangers, up to 800 m³/h, 25 bar and 160 °C. For a replacement request, what matters is the series and the code on the unit nameplate, the capacity, the refrigerant (R-410A, R-32, R-290, R-134a or R-454B) and the air or water flow.
What do we supply from the CIAT range?
| Product | Description |
|---|---|
| AQUACIAT and EREBA chillers and heat pumps | Air-to-water units; the EREBA 17-21 models have an inverter compressor. AQUACIAT LD R-32 (40–160 kW) is a chiller, ILD R-32 (40–150 kW) a heat pump; AQUACIAT POWER covers 170–940 kW in cooling. They are selected by capacity and refrigerant. |
| DYNACIAT and HYDROCIAT water-cooled units | Water-to-water chillers and heat pumps: DYNACIAT LG (25–190 kW, R-410A, scroll), DYNACIAT POWER LG (200–700 kW) and HYDROCIAT LW (273–1,756 kW, R-134a, screw compressor). They are selected by cooling capacity and water temperature. |
| CLIMACIAT FLOWAY air handling units | Double-flow, plug and play air handling units of 300–25,000 m³/h, plus AIR COMPACT (1,500–6,000 m³/h) and DFU (500–3,200 m³/h). The quotation data are the airflow, the available pressure and the indoor or outdoor version. |
| Dry coolers and rooftop units | OPERA (up to 1,100 kW) is a dry cooler and air-cooled condenser, and VEXTRA (100–2,000 kW) a dry cooler. VECTIOS and VECTIOS POWER are air-to-air rooftop units of 20–280 kW, with R-410A, R-454B or R-454C. |
Why CIAT?
- Air-to-water and water-to-water chillers and heat pumps, from 15 kW to over 1,700 kW — from small buildings to large installations
- R-32, R-290, R-410A, R-134a or R-454B refrigerant, depending on the series — to suit the installation's regulatory requirements
- Air handling units from 300 to 25,000 m³/h and compact rooftop units — for ventilation and air conditioning
- Dry coolers and air-cooled condensers up to 2,000 kW — for process circuits and refrigeration installations
- Three production centres in Europe, at Culoz, Montilla and Montluel — each with an in-house research and design centre
Which CIAT codes and series are requested most often?
| Code | Description |
|---|---|
| AQUACIAT LD R-32 | Air-to-water chiller, 40–160 kW |
| AQUACIAT ILD R-32 | Air-to-water heat pump, 40–150 kW |
| AQUACIAT POWER ILD R-32 | High-capacity air-to-water heat pump, 170–940 kW in cooling |
| EREBA ACCESS | Air-to-water chiller and heat pump, 17–40 kW |
| DYNACIAT LG | Water-to-water scroll chiller, 25–190 kW |
| DYNACIAT POWER LG | Water-to-water scroll chiller, 200–700 kW |
| HYDROCIAT LW | Water-to-water screw chiller, 273–1,756 kW |
| CLIMACIAT FLOWAY | Double-flow air handling unit, 300–25,000 m³/h |
| VECTIOS | Compact air-to-air rooftop unit, R-410A |
| VECTIOS POWER | High-capacity air-to-air rooftop unit, 100–280 kW |
| OPERA | Dry cooler and air-cooled condenser, up to 1,100 kW |
| VEXTRA | Dry cooler, 100–2,000 kW |
| EXPAIR | Precision air conditioning unit, 5–27 kW |
| ITEX | Gasketed plate heat exchanger |
Where is CIAT equipment used?
- Commercial buildings and offices — chillers, heat pumps and air handling units
- Hotels and retail spaces — air conditioning with rooftop units and comfort units
- Logistics facilities — unit heaters and rooftop units
- Spaces with precise temperature control — EXPAIR and MAGISTER precision air conditioning units
- Industrial and process installations — dry coolers and ITEX plate heat exchangers (HVAC, data centres, food, chemical, pharmaceutical)
How do we supply CIAT in Romania?
We can quote CIAT chillers and heat pumps, air handling units, rooftop units, dry coolers, precision units and ITEX heat exchangers. For an accurate quotation, send the series and the code on the unit nameplate, the cooling or heating capacity, the refrigerant, the air or water flow and the supply voltage. CIAT units are brought in to order. Parts can ship in 24–72 h when the item is in stock, locally or at the supplier; a unit supplied to order usually takes 1–4 weeks, and for large units, depending on the specification, the lead time may be longer. The exact lead time is stated in the quotation.
For a large unit or one with a non-standard refrigerant, we confirm the available version from the nameplate and the process data before quoting.
Frequently asked questions about CIAT
What does CIAT make?
Air conditioning and air handling equipment: AQUACIAT, DYNACIAT and HYDROCIAT chillers and heat pumps, CLIMACIAT FLOWAY units, VECTIOS rooftop units, OPERA and VEXTRA dry coolers, EXPAIR and MAGISTER precision units.
How do I choose the capacity of a CIAT chiller?
By the cooling load in kW, the outlet water temperature and the type of condensing (air or water). The series overlap in steps: AQUACIAT LD R-32 at 40–160 kW, DYNACIAT LG at 25–190 kW and HYDROCIAT LW at over 270 kW.
What sound-level and hydraulic versions does the CIAT AQUACIAT LD R-32 series have?
AQUACIAT LD R-32 is a 40–160 kW chiller with R-32 refrigerant and scroll compressors, in 12 sizes (150R–600R). It comes in two sound-level versions, standard and very low noise (LN), and three hydraulic versions: no module, with pump, or with pump and water buffer tank (the last two optional). We confirm the exact variant with the quotation.
Can I replace an old CIAT unit with a current one?
We check the replacement from the series on the nameplate, the capacity, the refrigerant and the connections. Newer series use different refrigerants (R-32, R-454B), so we confirm the version in the quotation, without assuming direct compatibility.
What data do I send for a quotation on a CIAT VECTIOS rooftop unit?
The airflow in m³/h, the available pressure, the coils required (heating, cooling) and the voltage. For an existing VECTIOS unit, the code on the nameplate speeds up the check.
How do I request a CIAT quotation?
Send the CIAT code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: CIAT (manufacturer documentation)