C.I.B. Unigas supplier in Romania
For C.I.B. Unigas we quote burners from the MINIFLAM, IDEA, B, C and N series, as well as spare parts for installed burners; for a quotation we need the series, the fuel, the output and the furnace pressure.
Founded in 1972 · Headquarters: Campodarsego (Padua), Italy
Who is C.I.B. Unigas and what does it make?
C.I.B. Unigas is an Italian manufacturer of industrial burners, a privately owned company founded in 1972, with its factory in Campodarsego, near Padua. The company designs, assembles and tests all its burners in Italy, and the catalogue lists about 1,400 models. The range covers burners for gas, diesel, heavy fuel oil and mixed gas/diesel fuel, used on steam, hot water and thermal oil boilers, in heating plants and in industrial processes. The burner is the component that sets efficiency, emissions and multi-fuel operation.
The range is divided into series, defined by minimum and maximum output in kW and by fuel type: MINIFLAM, IDEA, A, B, C, E, TECNOPRESS, NOVANTA, CINQUECENTO and N. The range starts at a few tens of kW (the IDEA series covers 19–570 kW) and continues with series for thousands of kW, such as the N series, at 1,200–13,000 kW, which includes heavy-fuel versions. The NOVANTA and CINQUECENTO series are the high-output burners, and the N series is intended for large industrial outputs. The same family can be ordered in versions for gas, for diesel or for mixed fuel.
The range aims at lower pollutant emissions and energy saving. When replacing an existing burner, the series and output are read from the nameplate, together with the fuel type, the combustion chamber pressure and the mounting dimension at the boiler.
What do we supply from the C.I.B. Unigas range?
| Product | Description |
|---|---|
| MINIFLAM, IDEA and A series | Low and medium output burners, from 19 kW to a few hundred kW, with diesel, gas or mixed gas/diesel versions. They are used on small boilers and in heating plants. |
| B, C and E series | Medium output burners, from hundreds of kW up to about 2,000 kW, with gas, diesel and mixed versions. They are fitted to medium-capacity hot water and steam boilers. |
| NOVANTA and CINQUECENTO series | High-output burners for industrial boilers, with outputs in the thousands of kW. They are chosen by the minimum and maximum output in kW and by the boiler fuel. |
| N series and TECNOPRESS series | The N series brings together heavy-fuel burners for large industrial outputs, up to 13,000 kW. TECNOPRESS is a separate series in the burner catalogue, also chosen by the output required and the fuel type. |
Why C.I.B. Unigas?
- Series defined by output and fuel, from tens of kW (IDEA, 19–570 kW) to thousands of kW (N, 1,200–13,000 kW) — the series is chosen to suit the load, not a universal model
- Versions for gas, diesel, heavy fuel oil and mixed gas/diesel — flexibility when the fuel changes
- High-output series NOVANTA, CINQUECENTO and N — for industrial steam and thermal oil boilers
- Production, assembly and testing at the Campodarsego factory — documentation and parts are identified by series
- The company's Unitech technical service — first firing and adjustments are handled separately from the burner supply
Which C.I.B. Unigas codes and series are requested most often?
| Code | Description |
|---|---|
| MINIFLAM | Low-output burner series |
| IDEA | Burner series, 19–570 kW |
| Series A | Low and medium output burner series |
| Series B | Medium-output burner series |
| Series C | Burner series, 200–1200 kW |
| Series E | Burner series, 250–2050 kW |
| TECNOPRESS | Burner series from the catalogue |
| NOVANTA | High-output burner series |
| CINQUECENTO | High-output series, 600–8000 kW |
| Series N | Heavy-fuel series, 1200–13000 kW |
| Unitech | Company technical service |
Where is C.I.B. Unigas equipment used?
- Industrial heating plants — burners for hot water and steam boilers
- Food and beverage industry — process steam
- Chemical and petrochemical industry — thermal oil and steam boilers
- District heating and large buildings — medium output burners
- Processes with fuel changeover — plants running on gas, diesel or heavy fuel
How do we supply C.I.B. Unigas in Romania?
We can prepare quotations for C.I.B. Unigas burners and spare parts, starting from the series and output on the nameplate of the existing burner or from the thermal load of the boiler. We supply them to order; usual parts generally in 1–4 weeks, while high-output burners can have a longer lead time, depending on the specification. For a correct quotation, send us the series and model, the fuel, the output required, the furnace pressure and the mounting dimensions at the boiler.
Matching a burner to a boiler is established from the real output, the furnace pressure and the fuel, and first firing and adjustment remain operations separate from the supply of the equipment.
Frequently asked questions about C.I.B. Unigas
What does C.I.B. Unigas make?
C.I.B. Unigas makes industrial and civil burners for gas, diesel, heavy fuel oil and mixed fuel, in about 1,400 models organised in series such as MINIFLAM, IDEA, A, B, C, E, NOVANTA, CINQUECENTO and N. The factory is in Campodarsego, near Padua, Italy.
How do I choose the right series for a boiler?
Start from the boiler output, the fuel and the furnace pressure. The series are defined by minimum and maximum output in kW and by fuel type. Send us the data from the boiler and existing burner nameplates, so we can identify the series that fits.
How soon can you supply C.I.B. Unigas burners or parts in Romania?
Supply is to order. Usual parts generally take 1–4 weeks, and can ship in 24–72 h when the item is in stock, locally or at the supplier. High-output burners can have a longer lead time; the exact date is confirmed in the quotation.
Can I replace an older C.I.B. Unigas burner with a current series?
It can be checked, but the output, the fuel, the mounting flange and the electrical control matter. Send the series and model from the nameplate, a photo of the burner and the flange dimensions at the boiler, so we can see whether a current series with the same mounting exists.
What data should I send for a gas and diesel burner quotation?
We need the thermal output required, the fuels used (natural gas, diesel or both), the combustion chamber pressure, the boiler type, the supply voltage and the mounting dimensions. If a burner is installed, add the series from its nameplate.
How do I request a C.I.B. Unigas quotation?
Send the C.I.B. Unigas code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: C.I.B. Unigas S.r.l. (manufacturer documentation)