Advantage Engineering supplier in Romania
Chillers, temperature control units, cooling towers
Founded in 1977 · Headquarters: Greenwood, Indiana, USA
Who is Advantage Engineering and what does it make?
Advantage Engineering was founded in 1977 and operates at Greenwood, near Indianapolis, in Indiana, on a campus with three production buildings and a warehouse, with more than 100,000 square feet (about 9,300 m²) under cover. The company designs and manufactures heat transfer equipment for industry: portable and central liquid chillers, temperature control units, evaporative cooling towers, pumping stations and tanks, filters and heat exchangers. Annual production is more than 1,200 portable chillers, 120 central chillers and 3,500 temperature control units.
Portable chillers cover from a quarter of a ton to 40 tons of cooling, with process fluid between about -7 and +27 °C (20–80 °F), for indoor installation. The central ones range from 5 to 180 tons, in air-cooled or water-cooled versions, as complete systems with a pumping station or as stand-alone modules; the Titan series is a central system on a single frame, with an integrated tank and pumps, expandable with APT or WPT modules. The temperature control units (TCU, also called Thermolator) recirculate water up to about 150 °C (300 °F) or oil up to 260 °C (500 °F), in the SR (SRV, SRG, SRT), G, T300, VE and Temptender series.
The evaporative cooling towers are non-metallic (fibreglass casing, PVC fill, TEFC motor) and can reach 270 tons. For injection moulding, extrusion, heat treatment, distillery or brewery plants, they cool moulds, hydraulic oil or processes.
What do we supply from the Advantage Engineering range?
| Product | Description |
|---|---|
| Portable chillers | Compact, self-contained systems with compressor, pump, tank and controls, from ¼ to 40 tons, air-cooled or water-cooled. Typical process fluid between 20 and 80 °F, for indoor installation. |
| Titan central chillers and APT modules | Titan: a complete system with tank and pumps on a common frame, air-cooled (with a remote condenser) or water-cooled, expandable. The multi-zone controller controls up to 6 independent refrigeration circuits, and the dual pump separates distribution from internal recirculation. |
| SR, G, T300 and VE temperature control units | The SR series with V controller has 10–34 kW heaters, ¾–7½ HP pumps, flow rates of 35–100 GPM and process temperatures of up to 250 °F. The immersion heater brings the water to the set temperature, and a modulating valve meters the cooling water. |
| Evaporative cooling towers | Fully non-metallic construction, with a fibreglass casing, PVC fill and TEFC motor, on a structural steel base. Sized for water at 85 °F at a wet bulb temperature of 78 °F, with anti-clog ABS nozzles. |
Why Advantage Engineering?
- A range in three capacity steps — portable chillers from ¼ to 40 tons, central chillers from 5 to 180 tons, towers of up to 270 tons
- Temperature control units with water up to 150 °C and with oil up to 260 °C — the SR, G, T300, VE and Temptender series, for moulds and processes
- Titan series — a central chiller with tank and pumps on a single frame, expandable with APT or WPT modules, with a controller for up to 6 refrigeration circuits
- Industrial construction, made in a single place — design, production and service from Greenwood
- Related equipment from the same source — pumping stations, 5,000 gallon tanks, filters and heat exchangers
Which Advantage Engineering codes and series are requested most often?
| Code | Description |
|---|---|
| Titan | Central chiller with tank and pumps on a common frame |
| APT | Central chiller module |
| SRV | Temperature control unit with V controller |
| SRG | Temperature control unit with G controller |
| SRT | Temperature control unit with T controller |
| SRV-1035 | SR model with V controller |
| SRG-300 | Temperature control unit series |
| SRT-300 | Temperature control unit series |
| VE series | Temperature control unit series |
| G series | Temperature control unit series |
| Temptender | Temperature control unit series |
| Hot Oil Units | Hot oil TCU units |
Where is Advantage Engineering equipment used?
- Plastics injection and extrusion — chillers and temperature control units for moulds
- Breweries and distilleries — glycol chillers for fluid at 25 °F
- General industrial processes — portable chillers for cooling process water
- Processes with jacketed vessels — cooling and heating with TCU units
- Hydraulics and heat exchangers — water cooled by evaporative towers
How do we supply Advantage Engineering in Romania?
We can quote Advantage chillers, temperature control units, towers, pumps and accessories, supplied to order. The lead time to order is usually 1–4 weeks for standard equipment; central systems, those with special configurations or oversize transport may have a longer lead time, confirmed in the quotation. For a correct request we need the thermal load (kW or tons of cooling), the fluid temperature, the flow rate, the condensation type (air or water), the supply voltage and frequency, because the manufacturer works to American standards, and, for replacements, the nameplate of the existing equipment.
The equipment is built for the American market, so we check the voltage, the frequency and the approvals for the local grid on request, for each model, and the actual capacity depends on the ambient temperature and on the fluid.
Frequently asked questions about Advantage Engineering
What products does Advantage Engineering make?
Advantage makes portable and central chillers, temperature control units (TCU), evaporative cooling towers, pumping stations, tanks, filters and heat exchangers. It was founded in 1977 and operates at Greenwood, in the state of Indiana.
How do I size a chiller or a TCU for a mould?
Start from the thermal load (kW) of the process, the fluid temperature wanted and the flow rate. For moulds a TCU with water or oil is usually used; for cooling below ambient temperature, a chiller. We need the mass of material, the cycle and the ambient temperature.
Do you supply Advantage equipment in Romania, and how quickly?
Yes, to order, usually 1–4 weeks for standard equipment. Central systems and special configurations have a longer lead time, which we state in the quotation.
Can I replace an old TCU with a model from the SR series?
Equivalences are established after checking. Send the nameplate of the existing equipment, the heater power, the pump power, the flow rate and the voltage. We check which current model from the SR or G series has the same connections and capacity.
What information do you need for a chiller quotation?
The thermal load, the fluid temperature, the flow rate, the condensation type (air or water), the installation environment (indoor or outdoor), the voltage available and whether the fluid contains glycol. With this information we choose between a portable, a central or a brewery system.
How do I request a Advantage Engineering quotation?
Send the Advantage Engineering code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Advantage Engineering (manufacturer documentation)