Thermax supplier in Romania
Absorption chillers and heat pumps, boilers and cogeneration
Headquarters: Pune, India
Who is Thermax and what does it make?
Thermax is an Indian industrial company based in Pune, active in clean energy, water and clean air. For the European market, the main interest is the line of absorption chillers and heat pumps, marketed through the subsidiary Thermax Europe Ltd of Milton Keynes, in the United Kingdom, which handles delivery, design and commissioning. The company also makes boilers, cogeneration plants, water treatment and air pollution control equipment.
An absorption chiller produces chilled water using waste heat (steam, hot water, exhaust gases or fuel) instead of mechanical compression; the refrigerant is water, and the absorbent is a lithium bromide solution. The range has five versions: with low-pressure steam (single effect, 175–12,300 kW), with medium and high-pressure steam (double effect, 350–7,100 kW), direct-fired on gas or fuel oil (350–4,000 kW), with hot water at 70–120 °C (175–6,000 kW) and with exhaust gases from engines or turbines (700–10,000 kW). The absorption heat pumps cover 500 kW–40 MW, with hot water up to 95 °C (Type I) or 160 °C (Type II).
In district heating, cogeneration or process, these machines are project equipment, not off-the-shelf parts. They are worth considering where waste heat is available, especially at cogeneration units, in the food and pharmaceutical industries or at data centres.
What do we supply from the Thermax range?
| Product | Description |
|---|---|
| Low-pressure steam absorption chillers | Single-effect version, fed with dry saturated steam from 0.1 to 3.5 kg/cm². Capacity 175–12,300 kW, chilled water down to -5 °C, continuous regulation between 10 and 100% of load. |
| Double-effect chillers (steam or direct-fired) | Version with steam at 150–180 °C and 4–10 kg/cm², 350–7,100 kW, or direct-fired on gas, LPG, diesel or fuel oil, 350–4,000 kW, with a COP between 1.3 and 1.5 on steam and between 1.2 and 1.35 direct-fired (relative to the lower calorific value). |
| Hot water and exhaust gas chillers | Machines for hot water of 70–120 °C (175–6,000 kW), with solar or geothermal sources, and for gases from 280 to 600 °C from cogeneration engines and turbines (700–10,000 kW), with a COP of 0.7–0.8 on hot water and 1.3–1.5 on exhaust gases. |
| Absorption heat pumps | Type I and Type II machines, plus combined heat pump and chiller modules, for recovering low-grade heat into hot water of up to 95 °C and 160 °C respectively, with a COP of up to 1.75. |
Why Thermax?
- Cooling from waste heat — heat from steam, exhaust gases or hot water replaces the compressor and reduce the electricity used for cooling
- Chilled water down to -5 °C — the steam version allows cold storage and food processing applications
- Series flows for the lithium bromide — reduced risk of internal corrosion and a design without crystallisation
- Tube material matched to the cooling water — titanium or stainless steel, including for seawater circuits
- Absorption heat pumps of 500 kW–40 MW — heat recovery from exhaust gases for district heating networks
Which Thermax codes and series are requested most often?
| Code | Description |
|---|---|
| Steam chiller, single effect | 175–12,300 kW, steam of 0.1–3.5 kg/cm² |
| Steam chiller, double effect | 350–7,100 kW, steam of 150–180 °C |
| Direct-fired chiller | 350–4,000 kW, gas, LPG, diesel or fuel oil |
| Hot water chiller | 175–6,000 kW, hot water of 70–120 °C |
| Exhaust gas chiller | 700–10,000 kW, gases of 280–600 °C |
| Heat pump, Type I | 500 kW–40 MW, hot water up to 95 °C |
| Heat pump, Type II | Heat transformer, hot water up to 160 °C |
| Heat pump and chiller module | Combined heating and cooling unit |
Where is Thermax equipment used?
- District heating — heat pumps for recovering heat from exhaust gases
- Cogeneration and trigeneration — chillers using exhaust gases from engines and turbines
- Pharmaceutical, chemical and food industry — process chilled water from steam or waste heat
- Data centres — cooling from the heat of cogeneration units
- Large buildings — air conditioning from steam, hot water or gases
How do we supply Thermax in Romania?
We can take an enquiry for a Thermax absorption chiller or heat pump and pass it on for checking. As these are configured, high-capacity equipment, the lead time depends on the project and may be longer depending on the specification; we confirm it only after the specification. For an indicative quotation we need the cooling or heating capacity wanted, the available heat source (steam, hot water, gases, fuel) with its parameters, the chilled or heated water temperatures, the quality of the cooling water and the installation site. Spare parts by code are quoted on the basis of the machine number.
Thermax equipment is supplied to order, and the design and commissioning of a complete installation are handled separately from the supply of the equipment.
Frequently asked questions about Thermax
What does Thermax make for Europe?
The European line, under Thermax Europe Ltd of Milton Keynes, includes absorption chillers and heat pumps, from 175 kW to 12.3 MW for cooling and from 500 kW to 40 MW for heating. The Indian company also makes boilers, cogeneration, water treatment and pollution control.
How do I size an absorption chiller?
Sizing starts from the available heat (steam with its pressure, hot water with its temperature, exhaust gases with flow and temperature) and from the cooling capacity required. The cooling tower water and the chilled water temperatures wanted matter; the version is chosen according to the source.
Do you supply Thermax equipment in Romania and in how long?
We can take the enquiry and check it. As these are project machines, the lead time may be longer depending on the specification, including for parts, and is set after the technical specification.
Can I replace an existing absorption chiller?
It can be analysed if we receive the make and year of the machine, the capacity, the heat source and the hydraulic connections. Compatibility with an existing installation, as well as keeping the foundations or the pipe routes, is analysed once these details are received.
What data do I send for an indicative quotation?
Send the capacity wanted, the heat source with its parameters, the chilled or hot water temperatures, the quality of the cooling water, the available space and, if there is one, the annual load profile. Also state whether the project is a new build or a refurbishment.
How do I request a Thermax quotation?
Send the Thermax code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Thermax Europe Ltd, Wikipedia (manufacturer documentation)