Trane supplier in Romania
From the Trane range we quote CenTraVac centrifugal chillers (CVHE, CVHG), Voyager rooftop units, air handling units and industrial heat pumps; the code on the unit's nameplate is enough for us to quote.
Founded in 1885 · Headquarters: Swords, Ireland (American head office: Davidson, North Carolina, USA)
Who is Trane and what does it make?
Trane is a global manufacturer of HVAC (Heating, Ventilation, Air Conditioning) systems for commercial and industrial applications. From centrifugal chillers of several megawatts for high-rise buildings, to custom air handling units (AHU) for pharma clean rooms, to industrial heat pumps for energy recovery, Trane covers a wide range of thermal applications. The Trane brand is present in commercial and industrial HVAC.
Trane equipment is specified and integrated in many different applications — centrifugal-compressor chillers for office buildings, rooftop package units for retail stores, air handling units for hospitals. Trane CenTraVac centrifugal compressors have a single rotating shaft supported by two bearings and a refrigerant-cooled motor, and the Tracer Summit automation system allows the whole building to be controlled and monitored from a single interface.
But Trane does not offer only equipment — it also offers energy audit and building optimisation services (analysis of consumption and retrofit proposals to reduce energy use), BMS integration (into BACnet, Modbus and LonWorks systems) and energy optimisation services, according to the manufacturer's offer. A Trane investment also includes continuous long-term support, not just the equipment.
What do we supply from the Trane range?
| Product | Description |
|---|---|
| Centrifugal chillers - CenTraVac series | Trane CenTraVac centrifugal chillers are advanced refrigeration units for large buildings (over 1 MW of cooling capacity). Multistage centrifugal compressor (2-3 stage compression) for efficient high compression ratios, driven by a refrigerant-cooled electric motor with a single shaft supported by two bearings. Condenser and evaporator made of copper tubes with heat-transfer enhancements (rifled tubes) for a compact surface. Refrigerant R-514A or R-1233zd (CDHH and CVHH models), both with ultra-low GWP. Full-load and part-load efficiency depend on the model and the operating conditions and are confirmed from the manufacturer's catalogue. Capacities between approximately 450 and over 14,000 kW (120 – over 4,000 tons). Integrated Tracer AdaptiView controller: automatic optimisation according to load, outdoor temperatures and energy tariff (demand response), predictive diagnostics with remote alerting. Applications: high-rise buildings (office towers), hospitals, universities, airports, malls, data centres. Installation: in the basement plant room or on the roof; separate cooling towers or dry-coolers are required. |
| Rooftop package units - Voyager series | Trane Voyager rooftop units are complete roof-mounted HVAC packages (all-in-one: cooling, heating, ventilation, filtration) for medium-sized commercial spaces (shops, restaurants, offices up to 500-1000 m²). The cooling capacity of the Voyager I series is approximately 16.7–31.7 kW; gas heating (YSD/YSH) or heat pump (WSD/WSH). Refrigerant R-410A. Indoor airflow is approximately 2,720–8,160 m³/h, depending on size. Standard 50 mm filters, with optional washable EU4 filters. Control: wall thermostat or integrated into the BMS via BACnet/Modbus. Galvanised steel casing with a thermally cured painted finish. Configurations: single-zone (a single thermal zone) or multi-zone with motorised dampers for differentiated distribution by zone. Applications: retail (shops, supermarkets), open-plan offices, restaurants, sports halls, industrial spaces with moderate thermal load. Advantages: fast installation (factory pre-assembled), low total cost, simplified maintenance (access from the roof), easy replacement (standardised footprint). |
| Air handling units (AHU) | Trane air handling units are built to order for applications that need fine control of air quality: hospitals (operating theatres, tuberculosis wards), pharma (clean rooms class A/B/C/D), laboratories (fume hoods, safety cabinets), food production (aseptic zones). Modular construction: fresh air/recirculation mixing sections, staged filtration (G4 pre-filter, F7-F9 fine filter, H13-H14 terminal HEPA), cooling coils (chilled water) and heating coils (hot water, steam, electric heaters), humidifier (steam, atomising), heat recovery unit (rotary, plate, run-around), supply fan and optionally return fan with EC-VSD motors. Casing with 50-100 mm thick sandwich panels (thermal and acoustic insulation), air tightness class L1 or L2 according to EN 1886, mechanical strength D1/D2, thermal bridging TB2/TB3. Airflow 500-100,000 m³/h, available static pressure up to 2500 Pa. Control: DDC (Direct Digital Control) with custom sequences - maintaining positive/negative pressure, outdoor temperature compensation, free-cooling where possible, demand-controlled ventilation according to CO2/occupancy. Critical applications: operating theatres (25+ air changes/hour, +15 Pa pressure, HEPA filtration), pharma clean rooms (laminar flow, particle classification according to EU GMP), bio-containment laboratories (cascaded negative pressure, HEPA exhaust filters). Compliance with GMP or HTM requirements is checked per project, from the manufacturer's documentation. Manufacturing lead time and factory tests are confirmed by the manufacturer for each configuration. |
| Industrial heat pumps | Trane heat pumps recover waste heat from industrial processes (equipment cooling water, exhaust air) and "pump" it to a higher temperature for reuse (building heating, domestic hot water, ventilation air preheating) - with the aim of reducing primary energy consumption. Principle: reversed refrigeration cycle with a compressor (scroll, screw or centrifugal), an evaporator (extracts heat from the cold source at 5-30°C) and a condenser (releases heat at the useful temperature of 40-90°C). COP (Coefficient of Performance) 3-5 depending on the temperature difference - for every kWh of electricity consumed you produce 3-5 kWh of heat. High-temperature refrigerants: R-134a, R-245fa, R-1233zd (low GWP) for condensing up to 90°C. Heat outputs depend on the model. Applications: heat recovery from data centre chillers for building heating, recovery from air compressors for DHW (domestic hot water), recovery from industrial washing processes. Integration: the Trane control automatically optimises between heat sources (pump + auxiliary boiler) according to energy cost and availability. The investment payback period varies with the application and the cost of energy. Compliance with EU directives on energy efficiency and CO2 emission reduction. |
Why Trane?
- CenTraVac centrifugal chillers with a single-rotating-shaft compressor and refrigerant-cooled motor
- High energy efficiency - good IPLV (Integrated Part Load Value) thanks to VSD and multiple stages
- Reliability and long service life - high MTBF, long-term service contracts available
- Smart automation - the Tracer platform for building control, monitoring and optimisation
- HVAC range - from chillers to AHUs, fan-coils, VRF and heat pumps in one unified ecosystem
Which Trane codes and series are requested most often?
| Code | Description |
|---|---|
| CVHE | CenTraVac centrifugal chiller, single shell, small-medium capacity |
| CVHF | CenTraVac centrifugal chiller, EarthWise generation, medium capacity |
| CVHG | CenTraVac centrifugal chiller, single shell, large capacity |
| CDHF | CenTraVac Duplex centrifugal chiller, two circuits, medium capacity |
| CDHG | CenTraVac Duplex centrifugal chiller, two circuits, large capacity |
| CVHH | Medium-voltage CenTraVac centrifugal chiller, E series |
| CDHH | Medium-voltage CenTraVac Duplex centrifugal chiller, E series |
| TSD060 | Voyager rooftop, cooling only, vertical installation, capacity step 60 |
| TSD090 | Voyager rooftop, cooling only, vertical installation, capacity step 90 |
| TSD120 | Voyager rooftop, cooling only, vertical installation, capacity step 120 |
| TSH060 | Voyager rooftop, cooling only, horizontal installation, capacity step 60 |
| TSH090 | Voyager rooftop, cooling only, horizontal installation, capacity step 90 |
| WSD060 | Voyager rooftop with heat pump, vertical installation, step 60 |
| WSH060 | Voyager rooftop with heat pump, horizontal installation, step 60 |
| YSD060 | Voyager rooftop with gas heating, vertical installation, step 60 |
| YSH060 | Voyager rooftop with gas heating, horizontal installation, step 60 |
Where is Trane equipment used?
- Commercial buildings (office buildings, malls, hotels)
- Healthcare (hospitals, clinics, medical centres)
- Pharmaceutical (factories with GMP clean rooms)
- Data centres (cooling high-density IT equipment)
- Education (universities, schools, campuses)
- Retail (shops, supermarkets, restaurants)
- Industry (factories with process air-conditioning requirements)
- Airports (passenger terminals, hangars)
- District heating/cooling (urban heat networks)
- Food production (aseptic zones, refrigerated warehouses)
How do we supply Trane in Romania?
We supply Trane HVAC equipment (chillers, rooftop units, air handling units, heat pumps) to order. We rely on the manufacturer's technical documentation for selection and sizing. As a general rule, some accessories or common parts can ship in 24–72 h when the item is in stock, locally or at the supplier, but custom AHU units or large chillers are complex systems, with lead times that can be longer depending on the specification, confirmed by the supplier for each configuration. For an accurate study, send us the heating/cooling requirement, the floor area or volume of the space and the air quality requirements. We come back with a technical proposal and the lead time confirmed by the supplier.
Availability of custom-built AHU units is checked on each request; Trane on-site service contracts are outside our offer.
Frequently asked questions about Trane
Which Trane CenTraVac chiller suits a medium-capacity office building?
A model from the CVHF family, single shell and medium capacity, covers most ordinary commercial buildings. For higher thermal loads or for operational redundancy, the CDHF Duplex version, with two independent refrigeration circuits, allows partial operation even if one circuit is shut down for maintenance.
What is the difference between Trane Voyager rooftop units with the TSD and TSH codes?
Both codes designate the same capacity step in cooling, but they differ in the rooftop installation orientation: TSD is intended for installation with vertical connections, and TSH for installation with horizontal connections. The choice depends on the layout of the building's air ducts.
Do you supply Trane equipment in Romania?
Yes, we order Trane chillers and rooftop units on the basis of the manufacturer's technical documentation; availability and lead time are confirmed in the quotation. For chillers the lead times can be longer, and for rooftop units usually 1–4 weeks to order, depending on the model and the options requested; the unit code must be confirmed before the order is placed.
What information should I send for a Trane Voyager rooftop quotation?
Useful details are the cooling capacity required, the type of heating wanted (electric, gas or heat pump) and the rooftop installation orientation. From these the suitable family follows: TSD/TSH for cooling only, WSD/WSH with heat pump or YSD/YSH with gas firing.
What do the Trane CDHF and CDHG series mean for CenTraVac chillers?
Both are Duplex versions, with two separate refrigeration circuits in the same casing, which gives partial-operation reserve in the event of a fault. CDHF covers the medium capacity step of the range, and CDHG is intended for projects with a higher cooling requirement.
How do I request a Trane quotation?
Send the Trane code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Trane Technologies, Wikipedia (manufacturer documentation)

