Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

STULZ supplier in Romania

For STULZ we quote CyberAir 3PRO DX and CW air conditioners, Explorer WPA, WSW and WS chillers, CyberCool WaterTec and Indoor, as well as parts, by unit name and nameplate code.

Founded in 1947 · Headquarters: Hamburg, Germany

Request a quote

Who is STULZ and what does it make?

STULZ started in 1947 in Hamburg, under the name "Electro AS GmbH Hamburg", and came to focus on precision air conditioning. In 1977 it launched modular precision air conditioning systems, and in 2003 the CyberAir 1 model, fitted as standard with high-efficiency EC fans. Today the range includes air conditioners for technical rooms, air-cooled or water-cooled chillers, air handling units, liquid cooling, humidifiers and monitoring systems.

STULZ units are found in a server room, a data centre, a laboratory or a telecommunications shelter. CyberAir 3PRO DX air conditioners cover 22–150 kW, the chilled water version CyberAir 3PRO CW goes from 22 to 260 kW, and CyberAir Mini and CyberLab serve small technical spaces. For chilled water, CyberCool Indoor offers 20–100 kW for indoor installation, Explorer WPA is an air-cooled chiller with two independent refrigeration circuits, and Explorer WSW is water-cooled.

At large capacities, CyberCool WaterTec with Turbocor technology and R1234ze refrigerant works between 350 and 1,510 kW, and CyberCool Explorer WS covers 280–1,860 kW and withstands inlet water temperatures of up to +32 °C, which allows Free Cooling operation for most of the year. CyberCool Free Cooling Booster adds the Free Cooling function (cooling without a compressor) to water-cooled chillers, together with a dry cooler.

What do we supply from the STULZ range?

ProductDescription
CyberAir precision air conditionersCyberAir 3PRO DX (22–150 kW) with direct expansion and CyberAir 3PRO CW (22–260 kW) with chilled water, for data centres, plus CyberAir Mini for small technical spaces and CyberLab for laboratories and industrial environments.
Water-cooled chillersCyberCool WaterTec (350–1,510 kW, 5 models in 4 sizes, Turbocor compressors), CyberCool Explorer WS (280–1,860 kW, ErP2021 compliant) and Explorer WSW, with electronic expansion valve and the option of Free Cooling.
Air-cooled chillersExplorer WPA for industrial process cooling, with two independent circuits and microchannel condensers, plus CyberCool Indoor of 20–100 kW for indoor installation.
Free Cooling BoosterA module that brings Free Cooling and mixed mode to water-cooled chillers, such as Explorer WSW, when low outdoor temperatures allow cooling without a compressor, in combination with a dry cooler installed outdoors.

Why STULZ?

  • Precision air conditioning developed since 1977 — CyberAir 3PRO DX and CW for technical rooms, from 22 kW up to 260 kW
  • Chillers with Free Cooling — Explorer WS works with inlet water up to +32 °C, and Free Cooling Booster complements water-cooled chillers
  • Turbocor technology for partial load — CyberCool WaterTec reduces the refrigerant charge and uses R1234ze
  • Redundancy in the same unit — Explorer WPA has two independent refrigeration circuits and microchannel condensers
  • Capacities from 20 to 1,860 kW — from CyberCool Indoor for indoor installation to Explorer WS for large data centres

Which STULZ codes and series are requested most often?

CodeDescription
CyberAir 3PRO DXPrecision air conditioner with direct expansion, 22–150 kW
CyberAir 3PRO CWPrecision air conditioner with chilled water, 22–260 kW
CyberAir MiniAir conditioner for small technical spaces
CyberLabAir conditioner for laboratories and technical environments
CyberCool WaterTecWater-cooled chiller with Turbocor, 350–1,510 kW
CyberCool Explorer WSWater-cooled chiller, 280–1,860 kW
Explorer WSWWater-cooled chiller, R513A refrigerant
Explorer WPAAir-cooled chiller, two refrigeration circuits
CyberCool IndoorIndoor chiller, 20–100 kW
CyberCool Free Cooling BoosterFree Cooling module for water-cooled chillers
CyberAir 1Precision air conditioner with EC fans as standard, launched in 2003

Where is STULZ equipment used?

  • Data centres — WaterTec and Explorer WS chillers and CyberAir 3PRO air conditioners
  • Telecommunications — air conditioning for shelters and technical rooms
  • Manufacturing industry — process chilled water from Explorer WPA chillers
  • Laboratories and technical environments — CyberLab and CyberCool Indoor units
  • Energy and transport — technical rooms air-conditioned with CyberAir

How do we supply STULZ in Romania?

We can quote STULZ precision air conditioners and chillers, as well as parts for installed units. We supply to order; usually 1–4 weeks for parts, while for chillers the lead time may be longer, depending on the specification. For a correct quotation we need the full unit name (for example CyberAir 3PRO CW or Explorer WPA), the nameplate code, the cooling capacity, the cooling type and, for parts, the part number and a photo of the component.

The compatibility of a part is confirmed from the exact unit name and the photo of the component.

Frequently asked questions about STULZ

What does STULZ make?

STULZ, from Hamburg, has been active since 1947 and makes precision air conditioners for technical rooms and data centres, air-cooled or water-cooled chillers, air handling units, liquid cooling, humidifiers and monitoring systems, for critical infrastructure and industrial processes.

How do I choose between a DX air conditioner and a chilled water one?

The DX version has its own refrigeration circuit and is used when no chilled water is available, while the chilled water version (CW) needs a cold water source but increases the capacity per unit. Tell us the thermal load in kW, the type of room and the available cooling source.

Do you supply STULZ equipment in Romania, and how quickly?

Yes, we supply to order; parts usually arrive in 1–4 weeks, while configured chillers and air conditioners may have a longer lead time. We give the exact lead time in the quotation, after checking the unit name.

Can an older STULZ chiller or air conditioner be replaced or repaired?

For repair parts, the full unit name and the serial number from the nameplate help. An equivalent replacement is established from data: we check the capacity, the refrigerant, the connections and the electrical supply from the data sent, then establish whether a current series, such as CyberAir 3PRO or Explorer, is suitable.

What data should I send for a chiller or air conditioner quotation?

Send the cooling capacity in kW, the supply and return water temperatures, the cooling type you want (air-cooled or water-cooled), the presence of a dry cooler for Free Cooling, the supply voltage and, for a technical room, the area and the thermal load of the equipment.

How do I request a STULZ quotation?

Send the STULZ code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: STULZ GmbH (manufacturer documentation)