Lovato supplier in Romania
From the Lovato range we quote BF series contactors, RF thermal relays, ADXN and ADXL soft starters and SM series motor protection switches; we start from the code on the device.
Founded in 1922 · Headquarters: Bergamo, Italy
Who is Lovato and what does it make?
Lovato is an Italian manufacturer of low-voltage electrical switchgear with over 100 years of activity, whose contactors are frequently found in industrial electrical installations - on motors, pumps, fans, compressors. A Lovato contactor rated for 1 million mechanical operations is built to this specification.
The Lovato range covers everything involved in controlling and protecting electric motors: contactors from 9A to 800A, thermal relays for overload protection, soft starters for smooth starting without current surges, motor circuit breakers, push-buttons and signalling. The design is practical: the contactors have clips for quick DIN-rail mounting, connection is made with automatic spring or screw terminals (your choice), and the coils are interchangeable without full disassembly. Control panels frequently use complete Lovato combinations: contactor, thermal relay, motor circuit breaker and push-buttons, all from the same family, with unified documentation.
The Lovato BF series covers 9A-95A modular contactors, and the B series heavy-duty contactors up to 800A, alongside RF thermal relays and ADXN/ADXL soft starters. For correct sizing of the protection devices, we recommend checking the Lovato catalogue and datasheets.
What do we supply from the Lovato range?
| Product | Description |
|---|---|
| BF series modular contactors | Lovato BF contactors are frequently used in small and medium industrial installations. The range covers 9A to 95A rated current, suitable for motors from 4kW to 45kW (at 400V AC3). The modular construction means a standard width for mounting on a 35mm DIN rail – a BF09 (9A) takes up only 45mm of width, which saves valuable space in panels. The main contacts are made of a silver alloy resistant to electric arcing, rated for 600,000 electrical operations in category AC-3 (motor starting). The coils are available in all standard voltages: 24V, 48V, 110V, 230V, 400V, both AC and DC – and are interchangeable without disturbing the power circuit. The coil can be replaced (for example from 230V to 24V) in a few minutes, with no rewiring. The auxiliary contact block is added on the side (1NO+1NC up to 4NO+4NC) with a simple clip. Standard IP20 protection, IP54 optional with a cover. |
| RF series thermal relays | Lovato RF thermal relays protect motors against overload and phase loss. They are not fuses – they do not interrupt the current directly, but command the contactor to open when they detect abnormal consumption. The bimetallic design with ambient temperature compensation ensures a tripping accuracy of ±5% whether the panel is at 20°C or 50°C. The current is set with a rotary knob on the front of the relay – the typical range is 30-50% adjustable (e.g. the RF38 is set between 23-32A). Trip class 10A means that at 7.2 x In the relay trips within 10 seconds at most - protection against overload, not short circuit (short circuit requires fuses or a protection switch). Manual test by pressing a button to check functionality. The NC (normally closed) contact is connected in series with the contactor coil – on tripping, the relay opens the contact and stops the contactor. Manual or automatic reset, as chosen. Mounts directly on Lovato contactors or separately on a DIN rail. |
| ADXN/ADXL series soft starters | A soft starter starts the asynchronous motor by gradually increasing the voltage, reducing the current and the mechanical shock of direct-on-line (DOL) starting. At Lovato, the ADXN (low and medium power) and ADXL (higher power) ranges cover this function. |
| SM series motor protection switches | Lovato switches in the SM range (for example SM1, SM3) are motor protection switches, with overload and short-circuit protection. |
Why Lovato?
- BF series modular contactors with a service life of 1 million mechanical operations / 600k electrical
- RF thermal relays with ambient temperature compensation and protection classes 10A/10/20
- Contactor coils with AC/DC voltages from 24V to 690V – interchangeable without full disassembly
- Utilisation categories AC-1 (resistive loads) and AC-3 (motors) certified to IEC 60947
- Modular auxiliary contacts that can be added on the side without disconnecting the main circuit
Which Lovato codes and series are requested most often?
| Code | Description |
|---|---|
| BF | range of modular contactors for motor control |
| BFS | range of safety contactors |
| BG | range of low-power contactors |
| RF9 | thermal relay for low motor protection currents |
| RF38 | thermal relay for medium motor protection currents |
| RF82 | thermal relay for high motor protection currents |
| RFE45 | electronic thermal relay for motor protection |
| ADXN | compact soft starter for low and medium power motors |
| ADXL | soft starter for higher power motors |
| VLB3 | variable frequency drive for motor control |
| SM1 | motor protection switch, SM range |
| SM3 | high-current motor protection switch, SM range |
| GA | load break switch for switching power circuits |
| P5ME | moulded case circuit breaker |
| LPC | range of control push-buttons and selectors |
| LPL | range of signalling lamps and monobloc devices |
| KX | range of limit switches |
| GX | range of rotary cam switches |
Where is Lovato equipment used?
- Process industry – control of pumps, mixers, conveyors
- HVAC – control of fans, air-conditioning compressors
- Water treatment – pumping stations, aeration
- Agriculture – irrigation systems, farm fans
- Food & Beverage – processing lines, refrigeration
- Textiles – motor controls for industrial sewing machines
- Construction – cranes, site hoists, concrete mixers
- OEM – integration into machines and equipment
How do we supply Lovato in Romania?
We start from the technical documentation of the manufacturer Lovato Electric. The exact availability of each code is checked with the supplier, and Lovato contactors, thermal relays and soft starters are supplied, in 24–72 h when the item is in stock, locally or at the supplier, for current codes, or, to order, usually in 1–4 weeks for special versions. For a correct quotation, send us the product code, the required rated current and the desired coil voltage. The firm delivery time is confirmed only after we check the actual availability at the supplier.
Availability for the Lovato ranges is checked on each request, and warranty service is handled through the manufacturer's service network.
Frequently asked questions about Lovato
What is the difference between Lovato BF series contactors and RF series thermal relays?
BF contactors switch the motor supply circuit on the command of the operator or the automation system, working as an electrically controlled switch. RF thermal relays are mounted next to the contactor and cut the supply automatically if the motor draws a current above the permitted limit, protecting the windings. Together they form a classic starter, and correct sizing takes the rated current of the motor into account.
What setting ranges does the Lovato RF38 thermal relay have, and which BF contactors does it pair with?
The RF38 thermal relay comes in 12 variants, from the RF38 0100 with a 0.63–1 A setting range up to the RF38 3800 with a 32–38 A setting range. It pairs with BF09 … BF38 contactors and is sensitive to phase loss, with manual or automatic reset. We confirm the exact variant in the quotation.
What information should I send for a Lovato contactor quotation?
State the rated current of the motor or of the controlled load, the control coil voltage, the number of poles required and whether additional auxiliary contacts are needed. For thermal relays, state the required setting current range, as it must match the real rated current of the protected motor.
What is a Lovato ADXN series soft starter and when is it used?
A soft starter reduces the starting current of an asynchronous motor by gradually raising the applied voltage instead of an abrupt direct start. The ADXN range is intended for low and medium power motors, where reducing mechanical and electrical shocks at start-up is desired. The correct choice depends on the motor power and on the type of load driven.
How do I request a Lovato quotation?
Send the Lovato code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Lovato Electric, Lovato Electric S.p.A. (manufacturer documentation)