Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Merus Power supplier in Romania

Active harmonic filters, STATCOM, SVC and battery storage

Headquarters: Ylöjärvi, Finland

Request a quote

Who is Merus Power and what does it make?

Merus Power is a Finnish company based in Ylöjärvi that designs and manufactures battery storage systems and power quality solutions. On the power quality side, the Merus family brings together four answers to the same problem, an industrial network polluted by harmonics, flicker or reactive power: the A2 active harmonic filter, the HPQ hybrid compensator, the STATCOM static synchronous compensator and the SVC static var compensator, with a separate line for modernising existing SVCs, regardless of the original manufacturer.

The Merus A2 active filter covers currents from 50 to 800 A, is supplied in a cabinet or as a module and works in parallel, each unit able to act as master or slave. Response time is under one grid cycle, and under 100 µs in harmonics mode. The HPQ combines a capacitor bank with a blocking inductance and an A2 module, so that harmonic filtering and power factor correction are handled by a single piece of equipment. SVC systems can be built for medium voltages from 3.3 kV to 38.5 kV and for ratings from 4 to 250 MVAr, each sized to the short-circuit level and the load.

Typical applications are the classic ones of heavy, variable loads: arc furnaces and ladle furnaces in steel mills, mining installations, lines with frequency converters in the chemical, pharmaceutical and paper industries, and wind and photovoltaic parks that must meet the grid code. Sizing depends on the load rating, the short-circuit level at the connection point, the measured harmonic spectrum and the grid operator's requirements.

What do we supply from the Merus Power range?

ProductDescription
Merus A2Active harmonic filter for currents from 50 to 800 A, in cabinet or module version. The units operate in parallel, without overcompensation or undercompensation, and comply with IEEE 519, G5/4 and EN 50160. Used in installations with frequency converters.
Merus HPQHybrid compensator that combines a capacitor bank with a blocking inductance and an A2 module. The capacitors cover most of the capacitive reactive power, while the active module handles the intermediate steps, harmonics and unbalanced currents.
Merus STATCOMModular static synchronous compensator for renewable applications and heavy industrial loads: voltage stabilisation, dynamic reactive power compensation, load balancing and harmonic filtering. The system consists of M2000 or PCM modules and a control and protection system.
Merus SVCStatic var compensator with thyristor valves for thyristor-controlled reactors (TCR), in a compact design that fits in a standard shipping container. Applied to arc furnaces, mines and transmission or distribution networks, for flicker and voltage control.

Why Merus Power?

  • A2 active filter for 50–800 A — in a cabinet or as a module, with units working in parallel, as master or slave
  • Response under one grid cycle and under 100 µs in harmonics mode — fast correction for suddenly changing loads
  • SVC at 3.3–38.5 kV and 4–250 MVAr — sized to the short-circuit level and the type of load
  • Modernisation of existing SVCs, for any manufacturer — extends the life of an installation with obsolete control electronics
  • HPQ hybrid — active filtering and power factor correction in a single system, without a separate power factor controller

Which Merus Power codes and series are requested most often?

CodeDescription
Merus A2Active harmonic filter, 50–800 A, cabinet or module
Merus HPQHybrid compensator: active filter plus capacitor bank
Merus STATCOMModular static synchronous compensator
Merus M2000Basic module of STATCOM systems
Merus PCMPower module used in STATCOM systems
Merus SVCStatic var compensator, 3.3–38.5 kV
Merus Thyristor ValveThyristor valve for thyristor-controlled reactors (TCR)
Merus C&PControl and protection system for STATCOM and SVC
Merus ESSBattery energy storage system
Merus PCSPower conversion system for storage
MeruscopeOptional remote monitoring service for Merus products

Where is Merus Power equipment used?

  • Steel mills — electric arc furnaces and ladle furnaces, with SVC or STATCOM for flicker
  • Mining and metallurgy — dynamic compensation for heavy, variable loads
  • Renewable energy — wind and photovoltaic parks that must meet the grid code
  • Chemicals, paper and pharmaceuticals — active filters for installations with many frequency converters
  • Pumping and wastewater treatment stations — harmonics from variable-speed drives

How do we supply Merus Power in Romania?

We can prepare quotations for Merus A2 active filters, HPQ compensators and, for larger projects, STATCOM and SVC systems. The equipment is supplied to order, and the lead time depends on the configuration: usually 1–4 weeks for standard modules, and it can be longer for project-sized systems such as STATCOM and SVC. For an accurate quotation, it helps to have the installation voltage and rating, the measured harmonic current or the list of consumers, the short-circuit level and, where applicable, the grid operator's requirements. The exact configuration and lead time are confirmed in the quotation.

Sizing studies for STATCOM and SVC systems are based on data measured at the installation, and their result is known only after that step.

Frequently asked questions about Merus Power

What products does Merus Power make?

Merus Power designs and manufactures in Finland battery energy storage systems and power quality solutions: the A2 active harmonic filter, the HPQ hybrid compensator, the STATCOM static synchronous compensator and the SVC static compensator, plus the modernisation of some SVCs from other manufacturers.

How do I size a Merus A2 active filter for my installation?

Start from the harmonic current of the non-linear load, not from the installation rating: the A2 covers 50–800 A, and units are paralleled for higher values. The calculation needs a power quality measurement or the list of frequency converters, together with the grid voltage and frequency.

Can you supply Merus systems in Romania, and with what lead time?

Yes, we supply the systems to order. For standard modules the lead time on order is usually 1–4 weeks; STATCOM and SVC systems are sized per project, so the lead time can be longer and is confirmed in the quotation.

Can an existing SVC from another manufacturer be modernised with the Merus solution?

There is an SVC modernisation line, applicable to installations of any origin. Feasibility depends on the condition of the valves, the control system and the installation diagrams; compatibility is confirmed on the basis of this data, which we review before quoting.

What data do you need for a STATCOM or SVC quotation?

Send the voltage at the connection point, the short-circuit level, the load rating and type (arc furnace, rolling mill, wind park), optionally a file with flicker and harmonic measurements, and the grid operator's requirements. The rating in MVAr is determined from this data.

How do I request a Merus Power quotation?

Send the Merus Power code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Merus Power (manufacturer documentation)