Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Niedax Group supplier in Romania

For Niedax we quote RLVC perforated trays, MTC wire mesh trays, cable ladders, GFK and stainless steel systems and protection tubes; for a quotation we need the route length, the tray dimensions, the cable load and the material wanted.

Founded in 1920 · Headquarters: Linz am Rhein, Germany

Request a quote

Who is Niedax Group and what does it make?

Niedax is a German manufacturer of cable support and routing systems, founded in 1920 and headquartered in Linz am Rhein. The programme includes perforated cable trays, wire mesh trays, cable ladders, systems for long spans, ship cable ladders, installation ducts, steel protection tubes and installation materials, that is brackets, C-profiles, clamps and wall plugs. The materials are hot-dip galvanised or Sendzimir steel, stainless steel and glass-fibre-reinforced polyester (GFK).

For industrial installations and for buildings, the NX CITO line is fitted without screws and without tools, by simple pressing. It includes the RLVC perforated tray, with a punched connector and offset perforation on the base for continuous fixing, and the MTC wire mesh tray, with the MTCG versions (G-shaped, for direct ceiling mounting) and MTCT (V-shaped, also used as a tray for luminaires). The perforated and wire mesh trays are VDE-tested for circuit integrity in case of fire, according to DIN 4102-12, whose classes E30, E60 and E90 mean 30, 60 or 90 minutes. For aggressive environments there are GFK systems (the K² and KP series) and stainless steel systems, and for offshore, wind and oil installations dedicated cable ladders and support structures are available.

Such systems appear in industrial halls, refineries, power plants, tunnels, office buildings and underground car parks, wherever cable routes must withstand load, corrosion or fire.

What do we supply from the Niedax Group range?

ProductDescription
RLVC perforated cable trayPerforated tray with a punched connector, offset perforation on the base for continuous fixing, slots for threaded rods and deep-drawn stiffening for rigidity. Supplied in hot-dip galvanised or Sendzimir steel and in stainless steel, compatible with the fittings and accessories of the same series.
MTC, MTCG and MTCT wire mesh trayU-shaped wire mesh tray with a welded connector, easy to cut and bend at the installation site, with good cable ventilation. MTCG, G-shaped, is fixed directly to the ceiling, and MTCT, V-shaped, serves as a lighting tray.
GFK, stainless steel and offshore systemsTrays and ladders in glass-fibre-reinforced polyester (K² and KP series), LFG protection ducts, stainless steel systems for aggressive environments and cable ladders for offshore, wind and oil and gas installations.
Protection tubes and installation materialsSteel protection tubes Ø 30 and Ø 60 with fittings and accessories, installation ducts in steel, PVC and aluminium, clamps, profiles and mounting rails, earthing materials and wall plugs for fixing routes to concrete or to profiles.

Why Niedax Group?

  • Tool-free installation in the NX CITO series — the RLVC perforated tray and the MTC wire mesh tray join by pressing, with an audible confirmation, and dismantling is also done without tools
  • Circuit integrity according to DIN 4102-12 (classes E30, E60 and E90) — perforated and wire mesh trays for emergency lighting, fire detection and other safety installations
  • Three material families in the same programme — galvanised steel, stainless steel and GFK, so the route is chosen according to the environment: indoor, outdoor, chemical or marine
  • MTC versions for different situations — MTCG for direct ceiling mounting, MTCT for lighting, MTCE as a universal piece for bends, drops or rises
  • Accessories matched to the system — KTAC brackets, ZC central hangers, GRBA and MTCDC clamps, so the route is completed with items from the same family

Which Niedax Group codes and series are requested most often?

CodeDescription
RLVCPerforated cable tray with punched connector, galvanised or stainless steel
MTCU-shaped wire mesh tray with welded connector
MTCGG-shaped wire mesh tray, for ceiling mounting
MTCTV-shaped wire mesh tray, for lighting
MTCEUniversal piece for MTC horizontal bend, drop or rise
KTACScrewless bracket, lengths 100–400
ZC 100-400Central hanger from C-profile, screwless
GRBA 40 E2Quick-fixing clamp for the MTC tray on brackets
MTCDC 24 E2Screwless clamp for standard RW dividers
MTCSC 22 E2Screwless clamp for 22 mm anchoring profiles
MTCUP 100Universal clamp for fixing cables and dividers
NX CITO LineSeries of trays with click connection, tool-free
K²GFK cable tray system
KPGFK cable tray system
LFGGFK cable protection duct systems

Where is Niedax Group equipment used?

  • Industry and process — cable routes in halls and production installations
  • Oil and gas — steel, stainless steel or GFK trays and ladders for corrosive environments
  • Energy — power plants, wind and photovoltaic parks
  • Infrastructure and transport — tunnels, railways and marine installations
  • Buildings and data centres — cable routes with circuit integrity in case of fire

How do we supply Niedax Group in Romania?

We can quote Niedax cable routing systems: RLVC perforated trays, MTC wire mesh trays, cable ladders, GFK and stainless steel systems, protection tubes and accessories. We need the route length, the tray width and height, the cable load per metre, the distance between brackets, the material (galvanised, stainless steel or GFK), the circuit integrity class, if applicable, and the installation environment. We bring them in to order, usually in 1–4 weeks; depending on the specification, the lead time may be longer, especially for large quantities or special versions. The exact lead time is confirmed in the quotation.

The E30, E60 or E90 circuit integrity class for a combination of tray, bracket and cable is established on the basis of the exact mounting system and the distance between supports.

Frequently asked questions about Niedax Group

What does Niedax make?

Niedax makes cable support and routing systems in Germany: perforated trays, wire mesh trays, cable ladders, systems for long spans, installation ducts, protection tubes and installation materials, in galvanised steel, stainless steel and glass-fibre-reinforced polyester.

How do I choose between the RLVC perforated tray and the MTC wire mesh tray?

RLVC has a perforated base, is rigid and is chosen for heavy cable loads and for routes with protection requirements. MTC is light, is cut and bent at the installation site and ventilates the cables well. Send us the load per metre, the distance between brackets and the installation environment.

What do E30, E60 and E90 mean, and what data should I send?

They are the classes of circuit integrity in case of fire, according to DIN 4102-12: 30, 60 or 90 minutes. The class is tied to the complete system, not just the tray. We need the class required, the cable type, the distance between supports and how the route is mounted.

Do you supply Niedax systems in Romania, and how soon?

Yes. The systems are brought in to order, usually in 1–4 weeks for series items. For large quantities or special versions the lead time may be longer, and the exact date is confirmed in the quotation on the basis of the item list.

What data should I send for a cable route quotation?

We need a list with the type of tray or ladder, the width and height, the total length, the shaped pieces (bends, branches, crossings), the brackets and hangers, the material or surface protection (galvanised or stainless steel) and the installation environment, indoor or outdoor, dry or aggressive.

How do I request a Niedax Group quotation?

Send the Niedax Group code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Niedax, Niedax Group (manufacturer documentation)